Heterodyne swept-source optical coherence tomography for complete complex conjugate ambiguity removal

被引:66
作者
Davis, AM [1 ]
Choma, MA [1 ]
Izatt, JA [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
关键词
optical coherence tomography; medical imaging; ophthalmic imaging;
D O I
10.1117/1.2136147
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fourier domain (FD) techniques have increasingly gained attention in optical coherence tomography (OCT). This is primarily due to their demonstrated sensitivity of two to three orders of magnitude over conventional time-domain techniques. FDOCT images are subject to two primary sources of artifacts. First, a complex conjugate ambiguity arises because the Fourier transform of the real-valued spectral interferometric signal is Hermitian symmetric. This ambiguity leads to artifactual superposition of reflectors at positive and negative pathlength differences between the sample and reference reflectors. Second, noninterferometric and sample autocorrelation terms appear at dc, obscuring reflectors at zero pathlength difference. We show that heterodyne detection in swept-source OCT (SSOCT) enables the resolution of complex conjugate ambiguity and the removal of noninterferometric and autocorrelation artifacts. We also show that complex conjugate ambiguity resolution via frequency shifting circumvents falloff induced by finite source linewidth in SSOCT when samples are shifted to large pathlength differences. We describe an efficient heterodyne SSOCT design that enables compensation of power losses from frequency-shifting elements. Last, we demonstrate this technique, coupled with wavenumber triggering and electronic demodulation, for in vivo imaging of the human anterior eye segment. (C) 2005 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:6
相关论文
共 12 条
[1]   Instantaneous quadrature low-coherence interferometry with 3 x 3 fiber-optic couplers [J].
Choma, MA ;
Yang, CH ;
Izatt, JA .
OPTICS LETTERS, 2003, 28 (22) :2162-2164
[2]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[3]  
CHOMA MA, 2005, J BIOMED OPT, V10, P9
[4]  
CHOMA MA, 2004, COH DOM OPT METH OPT, V8
[5]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[6]   Heterodyne swept-source optical coherence tomography for complete complex conjugate ambiguity removal [J].
Maheshwari, A ;
Choma, MA ;
Izatt, JA .
Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 :91-95
[7]   Instantaneous complex conjugate resolved spectral domain and swept-source OCT using 3x3 fiber couplers [J].
Sarunic, MV ;
Choma, MA ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2005, 13 (03) :957-967
[8]   In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical Doppler tomography [J].
White, BR ;
Pierce, MC ;
Nassif, N ;
Cense, B ;
Park, BH ;
Tearney, GJ ;
Bouma, BE ;
Chen, TC ;
de Boer, JF .
OPTICS EXPRESS, 2003, 11 (25) :3490-3497
[9]   Full range complex spectral optical coherence tomography technique in eye imaging [J].
Wojtkowski, M ;
Kowalczyk, A ;
Leitgeb, R ;
Fercher, AF .
OPTICS LETTERS, 2002, 27 (16) :1415-1417
[10]   Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting [J].
Yun, SH ;
Tearney, GJ ;
de Boer, JF ;
Bouma, BE .
OPTICS EXPRESS, 2004, 12 (20) :4822-4828