Randomized comparison of closed-loop feedback computer-controlled with manual-controlled infusion of phenylephrine for maintaining arterial pressure during spinal anaesthesia for Caesarean delivery

被引:51
作者
Ngan Kee, W. D. [1 ]
Khaw, K. S. [1 ]
Ng, F. F. [1 ]
Tam, Y. H. [1 ]
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Anaesthesia & Intens Care, Shatin, Hong Kong, Peoples R China
关键词
anaesthesia; spinal; arterial pressure; hypotension; Caesarean delivery; BLOOD-PRESSURE; PERFORMANCE; HYPOTENSION;
D O I
10.1093/bja/aes339
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Closed-loop feedback computer-controlled infusion has not been described for administering phenylephrine to maintain arterial pressure (AP) during spinal anaesthesia for Caesarean delivery. We aimed to compare AP control using this automated system with a previously described manual infusion system. We randomly allocated 222 healthy subjects having spinal anaesthesia for scheduled Caesarean delivery to have systolic AP maintained near baseline with phenylephrine (100 g ml(1)) by computer-controlled infusion utilizing a proportional algorithm or manual-controlled infusion utilizing an onoff algorithm. AP control was assessed by comparing the proportion of systolic AP measurements within 20 of baseline and by performance error (PE) calculations. A total of 212 subjects finished the study. In the computer-control group, 97 of systolic AP recordings fell within 20 of baseline compared with 95 in the manual-control group (P0.0004). For computer-control compared with manual-control, wobble was smaller [median 3.5 (inter-quartile range 2.54.8) vs 4.2 (3.35.9), P0.003], but there was no difference in the median PE [2.9 (0.34.7) vs 1.9 (04.2)], median absolute PE [4.7 (3.55.6) vs 4.7 (3.86.7)], or divergence [0.01 (0.030) vs 0.06 (0.260.08)]. Fewer interventions per subject for controlling AP were required in the computer-control group [2 (22) vs 10 (813), P0.001]. There were no differences in measured clinical outcomes. Within the constraints of the studied algorithms, closed-loop feedback computer-controlled phenylephrine infusion provided better AP control with fewer interventions required compared with manual-controlled infusion.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 9 条
  • [1] Fetal and maternal effects of phenylephrine and ephedrine during spinal anesthesia for cesarean delivery
    Cooper, DW
    Carpenter, M
    Mowbray, P
    Desira, WR
    Ryall, DM
    Kokri, MS
    [J]. ANESTHESIOLOGY, 2002, 97 (06) : 1582 - 1590
  • [2] Closed-loop feedback computer-controlled infusion of phenylephrine for maintaining blood pressure during spinal anaesthesia for caesarean section: a preliminary descriptive study
    Kee, W. D. Ngan
    Tam, Y. H.
    Khaw, K. S.
    Ng, F. F.
    Critchley, L. A.
    Karmakar, M. K.
    [J]. ANAESTHESIA, 2007, 62 (12) : 1251 - 1256
  • [3] Prevention of hypotension during spinal anesthesia for cesarean delivery - An effective technique using combination phenylephrine infusion and crystalloid cohydration
    Kee, WDN
    Khaw, KS
    Ng, FF
    [J]. ANESTHESIOLOGY, 2005, 103 (04) : 744 - 750
  • [4] Kee WDN, 2004, ANESTH ANALG, V98, P815
  • [5] Continuous Invasive Blood Pressure and Cardiac Output Monitoring during Cesarean Delivery A Randomized, Double-blind Comparison of Low-dose versus High-dose Spinal Anesthesia with Intravenous Phenylephrine or Placebo Infusion
    Langesaeter, Eldrid
    Rosseland, Leiv Arne
    Stubhaug, Audun
    [J]. ANESTHESIOLOGY, 2008, 109 (05) : 856 - 863
  • [6] Burden of Proof
    Smiley, Richard M.
    [J]. ANESTHESIOLOGY, 2009, 111 (03) : 470 - 472
  • [7] The Dose-Dependent Effects of Phenylephrine for Elective Cesarean Delivery Under Spinal Anesthesia
    Stewart, Adrienne
    Fernando, Roshan
    McDonald, Sarah
    Hignett, Rachel
    Jones, Tanya
    Columb, Malachy
    [J]. ANESTHESIA AND ANALGESIA, 2010, 111 (05) : 1230 - 1237
  • [8] Performance evaluation of two published closed-loop control systems using bispectral index monitoring -: A simulation study
    Struys, MMRF
    De Smet, T
    Greenwald, S
    Absalom, AR
    Bingé, S
    Mortier, EP
    [J]. ANESTHESIOLOGY, 2004, 100 (03) : 640 - 647
  • [9] MEASURING THE PREDICTIVE PERFORMANCE OF COMPUTER-CONTROLLED INFUSION PUMPS
    VARVEL, JR
    DONOHO, DL
    SHAFER, SL
    [J]. JOURNAL OF PHARMACOKINETICS AND BIOPHARMACEUTICS, 1992, 20 (01): : 63 - 94