On the Fundamental Limits of the Position Resolution of Position-Sensitive Scintillation Detector Using Continuous Crystal

被引:0
|
作者
Gal, J. [1 ]
Imrek, J. [1 ]
Kalinka, G. [1 ]
Kiraly, B. [1 ]
Nagy, F. [1 ]
Nyako, B. M. [1 ]
Molnar, J. [1 ]
Valastyan, I. [1 ]
Balkay, L. [2 ]
Kis, S. A. [2 ]
机构
[1] Hungarian Acad Sci, Inst Nucl Res, Bern Ter 18-C, Debrecen, Hungary
[2] Univ Debrecen, Inst Nucl Med, Debrecen, Hungary
来源
2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2011年
关键词
DEPTH; APD;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The factors determining the position resolution of continuous crystal based position sensitive scintillation gamma detectors are discussed. The key factors are the position functions which give the relation between the coordinates of the point of interaction (POI) and the responses of the photodetectors reading out of the scintillator. The physical phenomena limiting the position resolution are the statistical fluctuation of the detected photons and the electronic noise. For the standard deviation of the POI coordinates simple relations are deduced. It has been established that the contributions of both the statistical fluctuation and the noise to the standard deviation of the POI coordinates are inversely proportional to the square root of the detected photon numbers and the measure of these contributions can be characterised with the position resolution coefficients deduced from the position functions. A detailed discussion of the effect of the scintillator and photodetector characteristics is also given. As an example, calculations for the resolution coefficients in the case of the solid angle method with a chosen scintillator photodetector arrangement are given. The results show that the resolution coefficients as a function of the POI coordinates vary in a wide range. With realistic practical data and using almost the largest value for the resolution coefficients similar or better position resolution can be reached with continuous crystal than with a pixellated one.
引用
收藏
页码:3684 / 3689
页数:6
相关论文
共 24 条
  • [1] Theoretical study of three-dimensionally position-sensitive scintillation detector based on continuous crystal
    Gal, J.
    Kalinka, G.
    Nyako, B. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (03) : 607 - 615
  • [2] Enhancing the crystal discrimination for position-sensitive gamma-ray detectors by incorporating interaction position information
    Wei, Q.
    Yan, Z.
    Jiang, N.
    Xu, T.
    Lyu, Z.
    Ma, T.
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2025,
  • [3] Fundamental limits of scintillation detector timing precision
    Derenzo, Stephen E.
    Choong, Woon-Seng
    Moses, William W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (13) : 3261 - 3286
  • [4] Intrinsic spatial resolution and parallax correction using depth-encoding PET detector modules based on position-sensitive APD readout
    Dokhale, P. A.
    Silverman, R. W.
    Shah, K. S.
    Farrell, R.
    McClish, M. A.
    Entine, G.
    Cherry, S. R.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2666 - 2670
  • [5] Signal and noise properties of position-sensitive avalanche photodiodes
    Yang, Yongfeng
    Wu, Yibao
    Farrell, Richard
    Dokhale, Purushottam A.
    Shah, Kanai S.
    Cherry, Simon R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (19) : 6327 - 6336
  • [6] An animal PET scanner using flat-panel position-sensitive PMTs
    Okamoto, Takashi
    Ote, Kibou
    Sakai, Koichi
    Noda, Akihiro
    Shimizu, Keiji
    Masuda, Keisuke
    Ohmura, Tomohide
    Watanabe, Mitsuo
    ANNALS OF NUCLEAR MEDICINE, 2014, 28 (01) : 74 - 80
  • [7] High-Sensitivity Seawater Refraction Index Optical Measurement Sensor Based on a Position-Sensitive Detector
    Zhou, Guanlong
    Li, Liyan
    Zhou, Yan
    Chen, Xinyu
    SENSORS, 2024, 24 (07)
  • [8] A high sensitivity 4π view gamma imager with a monolithic 3D position-sensitive detector
    Ye, Qing
    Fan, Peng
    Wang, Rui
    Lyu, Zhenlei
    Hu, Ankang
    Wei, Qingyang
    Xia, Yan
    Yao, Rutao
    Liu, Yaqiang
    Ma, Tianyu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 937 (31-40) : 31 - 40
  • [9] A Position Sensitive γ-Ray Scintillator Detector With Enhanced Spatial Resolution, Linearity, and Field of View
    Domingo-Pardo, Cesar
    Goel, Namita
    Engert, Tobias
    Gerl, Juergen
    Isaka, Masahiro
    Kojouharov, Ivan
    Schaffner, Henning
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (12) : 2007 - 2014
  • [10] Energy and spatial resolution for a continuous scintillation crystal - interface - continuous scintillation crystal system in Positron Emission Tomography(PET)
    Carles, M.
    Ros-Garcia, A.
    Lerche, Ch. W.
    Sanchez, F.
    Sebastia, A.
    Benlloch, J. M.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3181 - +