Pneumothorax size measurements on digital chest radiographs: Intra- and inter- rater reliability

被引:9
|
作者
Thelle, Andreas [1 ]
Gjerdevik, Miriam [2 ,3 ]
Grydeland, Thomas [1 ]
Skorge, Trude D. [4 ]
Wentzel-Larsen, Tore [5 ,6 ,7 ]
Bakke, Per S. [8 ]
机构
[1] Haukeland Hosp, Dept Thorac Med, NO-5021 Bergen, Norway
[2] Haukeland Hosp, Norwegian Registry Long Term Mech Ventilat, Dept Thorac Med, NO-5021 Bergen, Norway
[3] Haukeland Hosp, Norwegian Registry Chron Obstruct Pulm Dis, Dept Thorac Med, NO-5021 Bergen, Norway
[4] Haukeland Hosp, Dept Occupat Med, NO-5021 Bergen, Norway
[5] Norwegian Ctr Violence & Traumat Stress Studies, Oslo, Norway
[6] Eastern & Southern Norway, Ctr Child & Adolescent Mental Hlth, NO-0405 Oslo, Norway
[7] Haukeland Hosp, Clin Res Ctr, NO-0405 Bergen, Norway
[8] Univ Bergen, Dept Clin Sci, NO-0405 Bergen, Norway
关键词
Pneumothorax size measurement; Digital chest radiograph; Rhea' method; Interrater reliability; Intrarater reliability; MANAGEMENT; GUIDELINES; AGREEMENT; CONSENSUS;
D O I
10.1016/j.ejrad.2015.07.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Detailed and reliable methods may be important for discussions on the importance of pneumothorax size in clinical decision-making. Rhea's method is widely used to estimate pneumothoraxsize in percent based on chest X-rays (CXRs) from three measure points. Choi's addendum is used for anterioposterior projections. The aim of this study was to examine the intrarater and interrater reliability of the Rhea and Choimethod using digital CXR in the ward based PACS monitors. Materials and methods: Three physicians examined a retrospective series of 80 digital CXRs showing pneumothorax, using Rhea and Choi's method, then repeated in a random order two weeks later. We used the analysis of variance technique by Eliasziw et al. to assess the intrarater and interrater reliability in altogether 480 estimations of pneumothorax size. Results: Estimated pneumothorax sizes ranged between 5% and 100%. The intrarater reliability coefficient was 0.98 (95% one-sided lower-limit confidence interval C 0.96), and the interrater reliability coefficient was 0.95 (95% one-sided lower-limit confidence interval 0.93). Conclusion: This study has shown that the Rhea and Choi method for calculating pneumothorax size has high intrarater and interrater reliability. These results are valid across gender, side of pneumothorax andwhether the patient is diagnosed with primary or secondary pneumothorax. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2038 / 2043
页数:6
相关论文
共 50 条
  • [1] Inter- and intra-rater reliability of handpump functionality field tests
    Smith, Daniel W.
    Wind, Samantha
    Markov, Igor A.
    Ongom, Stephen Atwii
    Davis, Jennifer
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 869
  • [2] Intra- and inter-rater reliability of digital image analysis for skin color measurement
    Sommers, Marilyn
    Beacham, Barbara
    Baker, Rachel
    Fargo, Jamison
    SKIN RESEARCH AND TECHNOLOGY, 2013, 19 (04) : 484 - 491
  • [3] Inter- and Intra-rater Reliability in Lithic Analysis: a Case Study in Handedness Determination Methodologies
    Ruck, Lana
    Holden, Chloe
    Putt, Shelby S. J.
    Schick, Kathy
    Toth, Nicholas
    JOURNAL OF ARCHAEOLOGICAL METHOD AND THEORY, 2020, 27 (02) : 220 - 244
  • [4] The intra- and inter-rater reliability of X-ray radiological measurements for patellar instability
    Smith, T. O.
    Cogan, A.
    Patel, S.
    Shakokani, M.
    Toms, A. P.
    Donell, S. T.
    KNEE, 2013, 20 (02) : 133 - 138
  • [5] Inter- and intra-rater reliability of the OCRA checklist method in video-recorded manual work tasks
    Rhen, Ida-Marta
    Forsman, Mikael
    APPLIED ERGONOMICS, 2020, 84
  • [6] Inter- and Intra-rater Reliability in Lithic Analysis: a Case Study in Handedness Determination Methodologies
    Lana Ruck
    Chloe Holden
    Shelby S. J. Putt
    Kathy Schick
    Nicholas Toth
    Journal of Archaeological Method and Theory, 2020, 27 : 220 - 244
  • [7] Degenerative findings on MRI of the cervical spine: an inter- and intra-rater reliability study
    Line Thorndal Moll
    Morten Wasmod Kindt
    Christina Malmose Stapelfeldt
    Tue Secher Jensen
    Chiropractic & Manual Therapies, 26
  • [8] Inter- and Intra-rater Reliability of the Draw-A-Person Test among Indian Children and Adolescents
    Srivastava, Garima
    Dhal, Anubha
    Chugh, Geetanjali
    Mehta, Manju
    Sagar, Rajesh
    Sreenivas, V.
    JOURNAL OF INDIAN ASSOCIATION FOR CHILD AND ADOLESCENT MENTAL HEALTH, 2008, 4 (04) : 88 - 94
  • [9] Intra-rater and inter-rater reliability of six musculoskeletal preparticipatory screening tests
    Zumana, Nosipho
    Olivier, Benita
    Godlwana, Lonwabo
    Martin, Candice
    SOUTH AFRICAN JOURNAL OF PHYSIOTHERAPY, 2019, 75 (01)
  • [10] Degenerative findings on MRI of the cervical spine: an inter- and intra-rater reliability study
    Moll, Line Thorndal
    Kindt, Morten Wasmod
    Stapelfeldt, Christina Malmose
    Jensen, Tue Secher
    CHIROPRACTIC & MANUAL THERAPIES, 2018, 26