Fiber-optic stethoscope: A cardiac monitoring and gating system for magnetic resonance microscopy

被引:44
作者
Brau, ACS [1 ]
Wheeler, CT [1 ]
Hedlund, LW [1 ]
Johnson, GA [1 ]
机构
[1] Duke Univ, Med Ctr, Ctr In Vivo Microscopy, Durham, NC 27710 USA
关键词
MRI; MR microscopy; ECG; EKG; cardiac monitoring; cardiac gating;
D O I
10.1002/mrm.10049
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A fundamental problem associated with using the conventional electrocardiograph (EGG) to monitor a subject's cardiac activity during magnetic resonance imaging (MRI) is the distortion of the ECG due to electromagnetic interference. This problem is particularly pronounced in MR microscopy (MRI of small animals at microscopic resolutions (< 0.03 mm(3))) because the strong, rapidly-switching magnetic field gradients induce artifacts in the animal's ECG that often mimic electrophysiologic activity, impairing the use of the ECG for cardiac monitoring and gating purposes. The fiber-optic stethoscope system offers a novel approach to measuring cardiac activity that, unlike the ECG, is immune to electromagnetic effects. The fiber-optic stethoscope is perorally inserted into the esophagus of small animals to optically detect pulsatile compression of the esophageal wall. The optical system is shown to provide a robust cardiac monitoring and gating signal in rats and mice during routine cardiac MR microscopy. Magn Reson Med 47: 314-321, 2002. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:314 / 321
页数:8
相关论文
共 22 条
[1]  
BRAU ACS, 2000, P 8 ANN M ISMRM DENV, P659
[2]   Removal of cardiac beat artifact in esophageal pressure measurement via a modified adaptive noise cancellation scheme [J].
Cheng, YP ;
Wu, HD ;
Jan, GJ ;
Wang, CY .
ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (03) :236-243
[3]  
Chia JM, 2000, J MAGN RESON IMAGING, V12, P678, DOI 10.1002/1522-2586(200011)12:5<678::AID-JMRI4>3.0.CO
[4]  
2-5
[5]   Magnetic resonance imaging accurately estimates LV mass in a transgenic mouse model of cardiac hypertrophy [J].
Franco, F ;
Dubois, SK ;
Peshock, RM ;
Shohet, RV .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (02) :H679-H683
[6]   OPTICAL-CONSTANTS OF WATER IN 200-NM TO 200-MUM WAVELENGTH REGION [J].
HALE, GM ;
QUERRY, MR .
APPLIED OPTICS, 1973, 12 (03) :555-563
[7]   MR-compatible ventilator for small animals: computer-controlled ventilation for proton and noble gas imaging [J].
Hedlund, LW ;
Cofer, GP ;
Owen, SJ ;
Johnson, GA .
MAGNETIC RESONANCE IMAGING, 2000, 18 (06) :753-759
[8]  
JOHNSON GA, IN PRESS RADIOLOGY
[9]   Minimizing interference from magnetic resonance imagers during electrocardiography [J].
Laudon, MK ;
Webster, JG ;
Frayne, R ;
Grist, TM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (02) :160-164
[10]   A SIMPLE FIBER OPTIC MONITOR OF CARDIAC AND RESPIRATORY ACTIVITY FOR BIOMEDICAL MAGNETIC-RESONANCE APPLICATIONS [J].
LEGENDRE, JP ;
MISNER, R ;
FORESTER, GV ;
GEOFFRION, Y .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :953-957