Comparing the indoor environmental quality of a displacement ventilation and passive chilled beam application to conventional air-conditioning in the Tropics

被引:27
作者
Pantelic, Jovan [1 ,2 ]
Rysanek, Adam [1 ,3 ]
Miller, Clayton [1 ,4 ]
Peng, Yuzhen [1 ]
Teitelbaum, Eric [5 ]
Meggers, Forrest [5 ,6 ]
Schlueter, Arno [1 ]
机构
[1] ETH, Architecture & Bldg Syst, HIB E 22,Stefano Frantzini Pl 1, CH-8093 Zurich, Switzerland
[2] Univ Calif Berkeley, Ctr Built Environm, Berkeley, CA 94720 USA
[3] Univ British Columbia, Sch Architecture & Landscape Architecture, Vancouver, BC, Canada
[4] Natl Univ Singapore, Sch Design & Environm, Singapore, Singapore
[5] Princeton Univ, Sch Architecture, Princeton, NJ 08544 USA
[6] Princeton Univ, Andlinger Ctr Energy & Environm, Princeton, NJ 08544 USA
关键词
Indoor environmental quality; Decentralized ventilation; Passive chilled beams; Displacement ventilation; Cohort study; Tropically acclimatized occupants; SICK BUILDING SYNDROME; THERMAL COMFORT; OFFICE; HEALTH; PRODUCTIVITY; PERFORMANCE; MOVEMENT; SYSTEM; IEQ;
D O I
10.1016/j.buildenv.2017.11.026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The satisfaction of occupants with an indoor environment supplied by a conventional central VAV air-conditioning system was compared to a novel system represented by decentralized ventilation units and a network of passive chilled beams. In parallel with occupant survey measurement of indoor air quality (IAQ) parameters was conducted with the developed wireless IAQ sensing kits. The same occupant cohort was surveyed for both systems, as occupants of the conventionally-conditioning office, known as the 'Previous Office' later moved into the office conditioned by the novel system, known as the '3for2 Office'. We observed that the perceived thermal comfort and air quality satisfaction of the occupants were markedly higher in the 3for2 Office than in the Previous Office. While occupants of the 3for2 Office could raise or lower indoor air temperatures, they appeared to be consistently satisfied with higher indoor air temperatures than that set by the building management of the Previous Office. The primarily Singaporean occupants of the 3for2 Office also felt thermally comfortable even when indoor air velocities in the office were measured to be below 0.1 m/s recommended by Singaporean Standards. The 3for2 Office's ventilation system was designed to supply outdoor air beyond minimal required ventilation rates, which lead to relatively low levels of CO2 and PM2.5 concentrations in the 3for2 office. We believe that higher ventilation rates resulting in lower pollutant concentrations are responsible for a higher-than-average survey score on air quality satisfaction. We also believe that enabling occupants to set air temperature in the space resulted in higher-than-average thermal comfort satisfaction.
引用
收藏
页码:128 / 142
页数:15
相关论文
共 36 条
[1]   Associations of Cognitive Function Scores with Carbon Dioxide, Ventilation, and Volatile Organic Compound Exposures in Office Workers: A Controlled Exposure Study of Green and Conventional Office Environments [J].
Allen, Joseph G. ;
MacNaughton, Piers ;
Satish, Usha ;
Santanam, Suresh ;
Vallarino, Jose ;
Spengler, John D. .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2016, 124 (06) :805-812
[2]  
American Society of Heating, 2014, TECH REP
[3]  
[Anonymous], 2014, TECH REP
[4]  
[Anonymous], BUILDING ENV
[5]  
Bauman F., FIELD STUDY IMPACT D
[6]  
BOMA, 2003, COMMERC INVEST R EST, V22, P24
[7]  
Building and Construction Standards Committee, 2016, TECH REP
[8]   Assessing building performance in use 1: the Probe process [J].
Cohen, R ;
Standeven, M ;
Bordass, B ;
Leaman, A .
BUILDING RESEARCH AND INFORMATION, 2001, 29 (02) :85-102
[9]  
Fanger PO, 2001, INT J REFRIG, V24, P148
[10]   Benefits and costs of improved IEQ in US offices [J].
Fisk, W. J. ;
Black, D. ;
Brunner, G. .
INDOOR AIR, 2011, 21 (05) :357-367