Development of New Copper(II) Ion-Selective Poly(vinyl chloride) Membrane Electrode Based on 2,6-Diacetylpyridine-(1R)-(-)-Fenchone Diazine Ligand

被引:0
作者
Isa, Illyas Md [1 ,2 ]
Saidin, Mohamad Idris [1 ]
Ahmad, Mustaffa [1 ]
Hashim, Norhayati [1 ,2 ]
Ghani, Sazelli A. [3 ]
Si, Suyanta M. [4 ]
机构
[1] Univ Pendidikan Sultan Idris, Fac Sci & Math, Dept Chem, Tanjong Malim 35900, Perak, Malaysia
[2] Univ Pendidikan Sultan Idris, Fac Sci & Math, Nanotechnol Res Ctr, Tanjong Malim 35900, Perak, Malaysia
[3] Univ Pendidikan Sultan Idris, Fac Sci & Math, Dept Math, Tanjong Malim 35900, Perak, Malaysia
[4] Yogyakarta State Univ, Fac Math & Nat Sci, Dept Chem Educ, Yogyakarta, Indonesia
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2013年 / 8卷 / 09期
关键词
Copper(II) ion membrane electrode; 2,6-diacetylpyridine-(1R)-(-)-fenchone diazine ligand; PVC; Potentiometry; CARBON-PASTE ELECTRODE; POTENTIOMETRIC SENSORS; PVC MATRIX; ICP-MS; PRECONCENTRATION; AAS; PORPHYRINS; EXTRACTION; CADMIUM; CARRIER;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The construction and performance characteristics of polymeric membrane electrodes based on 2,6-diacetylpyridine-(1R)-(-)-fenchone diazine ligand (A) for quantification of copper ions, are described. Effect of various plasticizers and anion excluder, sodium tetraphenylborate (NaTPB) was studied and improved performance was observed at several instances. Best performance was obtained with the membrane having the following composition; A (7): PVC (50): TMDP (86): NaTPB (1). The membrane electrodes exhibits Nernstian response in the concentration range of 1.0x10 (5) to 1.0x10 (1) M with a detection limit of 2.5x10(-6) M and wide pH range (4.0-8.0). The potentiometric selectivity coefficient values as determined by fixed interference method indicate excellent selectivity for copper ions over interfering cations. Each electrode possesses a fast response time of below 20s and a shelf life period of 3 months. The analytical utility of the proposed electrode was demonstrated by its application in the determination of copper in wastewater samples and the results were in agreement with those obtained with an atomic absorption spectroscopy (AAS) method.
引用
收藏
页码:11175 / 11185
页数:11
相关论文
共 36 条
[1]  
ALPAT SK, 2008, SENSOR ACTUAT B-CHEM, V128, P273
[2]   Simultaneous determination of arsenic, cadmium, copper, chromium, nickel, lead and thallium in total digested sediment samples and available fractions by electrothermal atomization atomic absorption spectroscopy (ET AAS) [J].
Alvarez, Maria A. ;
Carrillo, Genesis .
TALANTA, 2012, 97 :505-512
[3]  
Bakeman N, 2012, INT J ELECTROCHEM SC, V7, P4574
[4]  
BRZOZKA Z, 1988, ANALYST, V113, P1803
[5]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[6]   Evaluation of a carbon paste electrode modified with organofunctionalised SBA-15 nanostructured silica in the simultaneous determination of divalent lead, copper and mercury ions [J].
Cesarino, Ivana ;
Marino, Glimaldo ;
do Rosario Matos, Jivaldo ;
Gomes Cavalheiro, Eder Tadeu .
TALANTA, 2008, 75 (01) :15-21
[7]   Membrane solid phase microextraction with alumina hollow fiber on line coupled with ICP-OES for the determination of trace copper, manganese and nickel in environmental water samples [J].
Cui, Chao ;
He, Man ;
Hu, Bin .
JOURNAL OF HAZARDOUS MATERIALS, 2011, 187 (1-3) :379-385
[8]   Use of Nb2O5-SiO2 in an automated on-line preconcentration system for determination of copper and cadmium by FAAS [J].
da Silva, EL ;
Ganzarolli, EM ;
Carasek, E .
TALANTA, 2004, 62 (04) :727-733
[9]   Determination of heavy metals by ICP-OES and F-AAS after preconcentration with 2,2'-bipyridyl and erythrosine [J].
Feist, Barbara ;
Mikula, Barbara ;
Pytlakowska, Katarzyna ;
Puzio, Bozena ;
Buhl, Franciszek .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 152 (03) :1122-1129
[10]   Copper(H)e-selective potentiometric sensors based on porphyrins in PVC matrix [J].
Gupta, V. K. ;
Jain, A. K. ;
Maheshwari, G. ;
Lang, Heinrich ;
Ishtaiwi, Z. .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 117 (01) :99-106