Dose reassessment by using PTTL method in MTS-N (LiF:Mg, Ti) thermoluminescent detectors

被引:8
作者
Budzanowski, M. [1 ]
Sas-Bieniarz, A. [1 ]
Bilski, P. [1 ]
Bubak, A. [1 ]
Kopec, R. [1 ]
机构
[1] Polish Acad Sci IFJ PAN, Inst Nucl Phys, PL-31342 Krakow, Poland
关键词
Thermoluminescent dosimetry; Dose reassessing; Phototransferred thermoluminescence (PTTL); TLD-100; DOSIMETRY;
D O I
10.1016/j.radmeas.2012.12.019
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The thermoluminescent (TLD) method is one of the most commonly used in dose measurements in radiation protection dosimetry. Due to its many advantages this method is widely spread. However, TLD has especially one disadvantage which is very inconvenient: the dose information in already read detectors is erased and in routine standard way the dose can not be reassessed. The positive is that this shortcoming can be eliminated by applying UV radiation. After first readout the same detector can be subjected to UV exposure and then read once again to reassess the dose. This method for reassessment of dose is based on phototransferred thermoluminescence (PTTL). In an irradiated TL detector deep traps are not emptied during the first readout. During exposure to UV, electrons are transferred from deep traps to shallower dosimetric traps. This TL signal emerging during the second readout following UV illumination is called phototransferred thermoluminescence. A method for reassessment of dose in a previously readout TLD is presented in this work. Experiments show that the method works well within region of doses between 5 and 50 mGy, but could be applied for higher doses as well. The efficiency of dose reassessment reaches about 17 percent of the first readout. The method could be a noticeable improvement in TLD dosimetry, giving more opportunities for better control and reliability of measurements. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:389 / 392
页数:4
相关论文
共 6 条
[1]   On the reassessment of doses in TL-dosimetry by measuring the residual dose [J].
Abraham, A. ;
Weinstein, M. ;
German, U. ;
Alfassi, Z. B. .
RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) :113-116
[2]   Phototransferred thermoluminescence [J].
Alexander, CS ;
McKeever, SWS .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1998, 31 (20) :2908-2920
[3]  
BHASIN BD, 1987, RADIAT PROT DOSIM, V20, P181
[4]   A simple UV irradiator for low dose reassessment with LiF TLD-100 [J].
Delgado, A ;
Unamuno, V ;
Muniz, JL ;
Correcher, V ;
Ros, JMG .
RADIATION PROTECTION DOSIMETRY, 1996, 67 (04) :303-306
[5]   APPLICATION OF GLOW CURVE ANALYSIS-METHODS TO IMPROVE TLD-100 DOSE REASSESSMENT PERFORMANCE [J].
DELGADO, A ;
ROZ, JMG ;
MUNIZ, JL ;
PORTILLO, JC .
HEALTH PHYSICS, 1992, 62 (03) :228-234
[6]  
Muñiz JL, 1999, RADIAT PROT DOSIM, V85, P63