Capillary zone electrophoresis of glycopeptides under controlled electroosmotic flow conditions coupled to electrospray and matrix-assisted laser desorption/ionization mass spectrometry

被引:39
作者
Amon, S [1 ]
Plematl, A [1 ]
Rizzi, A [1 ]
机构
[1] Univ Vienna, Inst Analyt Chem & Food Chem, A-1090 Vienna, Austria
关键词
capillary coating; capillary electrophoresis; CE-MS; glycopeptide; multistage mass spectrometry;
D O I
10.1002/elps.200500725
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Defined conditions of EOF along with different pH values of the BGE were compared for the purpose of analyzing glycopetides by CZE coupled to MS (CZE-MS). Hyphenation to MS involved ESI as well as MALDI, and single-stage and multistage MS were applied. Variation of the EOF was accomplished by selecting appropriate coatings for the capillary, namely hexadimethrine bromide (HDMB) and HDMB/dextran sulfate. A high and reproducible anodic and cathodic EOF, respectively, was obtained in both approaches, allowing the detection of analytes with net positive as well as negative charge in one single run. Thus, a fast and sensitive determination of the glycopeptides in a tryptic digest of antithrombin, chosen as a test sample, was achieved. Ionization suppression effects, a phenomenon typically observed with glycopeptides in MS analysis, were minimized thanks to separation from other peptides present. The high stability of the coatings permitted the generation of mass spectra without interfering peaks originating from the coating polymers. The high EOF generated by the coatings facilitated the maintenance of a stable spray when coupling to ESI-MS, and a stable CZE current when working with a sheath flow-assisted analyte deposition onto MALDI targets, respectively. In conclusion, CZE-MS could be demonstrated as a robust complementary method to capillary RP-HPLC-MS in combination with both soft-ionization techniques, ESI and MALDI, generally, and particularly in the context of glycopeptide analysis.
引用
收藏
页码:1209 / 1219
页数:11
相关论文
共 36 条
  • [1] On the frequency of protein glycosylation, as deduced from analysis of the SWISS-PROT database
    Apweiler, R
    Hermjakob, H
    Sharon, N
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 1999, 1473 (01): : 4 - 8
  • [2] Characterization of protein glycoforms by capillary-zone electrophoresis nanoelectrospray mass spectrometry
    Bateman, KP
    White, RL
    Yaguchi, M
    Thibault, P
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) : 327 - 344
  • [3] Bateman KP, 1998, J MASS SPECTROM, V33, P1109, DOI 10.1002/(SICI)1096-9888(199811)33:11<1109::AID-JMS728>3.0.CO
  • [4] 2-1
  • [5] Never say never again: protein glycosylation in pathogenic bacteria
    Benz, I
    Schmidt, MA
    [J]. MOLECULAR MICROBIOLOGY, 2002, 45 (02) : 267 - 276
  • [6] Combination of capillary electrophoresis and matrix-assisted laser desorption ionization mass spectrometry for glycosylation analysis of a human monoclonal anti-Rhesus(D) antibody
    Bihoreau, N
    Ramon, C
    Lazard, M
    Schmitter, JM
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1997, 697 (1-2): : 123 - 133
  • [7] High-performance capillary electrophoresis for in-process control in the production of antithrombin III and human clotting factor IX
    Buchacher, A
    Schulz, P
    Choromanski, J
    Schwinn, H
    Josic, D
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 802 (02) : 355 - 366
  • [8] Analysis of recombinant DNA-derived glycoproteins via highperformance capillary electrophoresis coupled with off-line matrix-assisted laser desorption ionization time-of-flight mass spectrometry
    Chakel, JA
    Pungor, E
    Hancock, WS
    Swedberg, SA
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1997, 689 (01): : 215 - 220
  • [9] On-target fraction collection for the off-line coupling of capillary isoelectric focusing with matrix-assisted laser desorptioin/ionization mass spectrometry
    Chartogne, A
    Gaspari, M
    Jespersen, S
    Buscher, B
    Verheij, E
    van der Heijden, R
    Tjaden, U
    van der Greef, J
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (03) : 201 - 207
  • [10] Investigation of the potential of capillary electrophoresis with off-line matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for clinical analysis: Examination of a glycoprotein factor associated with cancer cachexia
    Choudhary, G
    Chakel, J
    Hancock, W
    Torres-Duarte, A
    McMahon, G
    Wainer, I
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (04) : 855 - 859