Effect of Blinking on Tear Volume After Instillation of Midviscosity Artificial Tears

被引:37
作者
Palakuru, Jayachandra R. [2 ]
Wang, Jianhua [1 ,2 ]
Aquavella, James V. [2 ]
机构
[1] Univ Miami, Bascom Palmer Eye Inst, Miller Sch Med, Miami, FL 33136 USA
[2] Univ Rochester, Dept Ophthalmol, Rochester, MN USA
基金
美国国家卫生研究院;
关键词
D O I
10.1016/j.ajo.2008.06.020
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine by optical coherence tomography (OCT) the effect of blinking on ocular surface tear volume after instillation of artificial tears. DESIGN: Experimental study. METHODS: Normal human eyes (n = 21) were imaged to obtain dimensions of the tear film and menisci during blinking. The imaging was carried out immediately and five minutes after the instillation of 35 mu l midviscosity artificial tears (1.0% carboxymethylcellulose; Refresh Liquigel; Allergan, Irvine, California, USA). The exposed ocular surface area and the lid lengths were used to calculate the volumes. RESULTS: Immediately after the instillation, total tear volume was increased (P < .001) compared with five minutes after the instillation, with the major increases in the lower tear meniscus volume and tear film volume. After the instillation, blinking caused tear loss in total tear volume because of the decrease of the lower tear meniscus volume (P < .05). In contrast, blinking increased the tear film volume (P < .05). At the end of the eye-opening period, tear film volume decreased and lower tear meniscus volume increased significantly (P < .05), with no significant changes in total tear volume (P > .05). During the blink cycle immediately after the instillation, net loss was evident in tear film volume, lower tear meniscus volume, and total tear volume (P < .05). CONCLUSIONS: Blinking plays a crucial role in distribution and removal of instilled tears. When the tear system is overloaded, the increase in blink output helps restore balance. (Am J Ophthalmol 2008;146920-924. (C) 2008 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:920 / 924
页数:5
相关论文
共 26 条
[1]   The influence of eye solutions on blinking and ocular comfort at rest and during work at video display terminals [J].
Acosta, MC ;
Gallar, J ;
Belmonte, C .
EXPERIMENTAL EYE RESEARCH, 1999, 68 (06) :663-669
[2]  
Baxter Stephanie A, 2004, Ocul Surf, V2, P255
[3]  
BENEDETTO DA, 1975, INVEST OPHTH VISUAL, V14, P887
[4]  
Braun RJ, 2003, MATH MED BIOL, V20, P1
[5]  
CHAVIS RM, 1978, ARCH OPHTHALMOL-CHIC, V96, P2066
[6]   Biopharmaceutical considerations in topical ocular drug delivery [J].
Davies, NM .
CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2000, 27 (07) :558-562
[7]  
DOANE MG, 1981, OPHTHALMOLOGY, V88, P844
[8]   Temporal changes in the tear menisci following a blink [J].
Johnson, Michael E. ;
Murphy, Paul J. .
EXPERIMENTAL EYE RESEARCH, 2006, 83 (03) :517-525
[9]   The thickness of the tear film [J].
King-Smith, PE ;
Fink, BA ;
Hill, RM ;
Koelling, KW ;
Tiffany, JM .
CURRENT EYE RESEARCH, 2004, 29 (4-5) :357-368
[10]   Tear meniscus measurement in the diagnosis of dry eye [J].
Mainstone, JC ;
Bruce, AS ;
Golding, TR .
CURRENT EYE RESEARCH, 1996, 15 (06) :653-661