An image-guided precision proton radiation platform for preclinical in vivo research

被引:39
作者
Ford, E. [1 ]
Emery, R. [1 ]
Huff, D. [1 ]
Narayanan, M. [1 ]
Schwartz, J. [1 ]
Cao, N. [1 ]
Meyer, J. [1 ]
Rengan, R. [1 ]
Zeng, J. [1 ]
Sandison, G. [1 ]
Laramore, G. [1 ]
Mayr, N. [1 ]
机构
[1] Univ Washington, Dept Radiat Oncol, Seattle, WA 98195 USA
关键词
proton therapy; radiobiology; preclinical; image-guidance; RADIOCHROMIC FILM DOSIMETRY; RELATIVE BIOLOGICAL EFFECTIVENESS; INDUCED LUNG INJURY; CRANIAL IRRADIATION; GENE-EXPRESSION; HIGH-RESOLUTION; GROWTH DELAY; MONTE-CARLO; BEAM; MODEL;
D O I
10.1088/1361-6560/62/1/43
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
There are many unknowns in the radiobiology of proton beams and other particle beams. We describe the development and testing of an image-guided low-energy proton system optimized for radiobiological research applications. A 50 MeV proton beam from an existing cyclotron was modified to produce collimated beams (as small as 2 mm in diameter). Ionization chamber and radiochromic film measurements were performed and benchmarked with Monte Carlo simulations (TOPAS). The proton beam was aligned with a commercially-available CT image-guided x-ray irradiator device (SARRP, Xstrahl Inc.). To examine the alternative possibility of adapting a clinical proton therapy system, we performed Monte Carlo simulations of a range-shifted 100 MeV clinical beam. The proton beam exhibits a pristine Bragg Peak at a depth of 21 mm in water with a dose rate of 8.4 Gy min(-1) (3 mm depth). The energy of the incident beam can be modulated to lower energies while preserving the Bragg peak. The LET was: 2.0 keV mu m(-1) (water surface), 16 keV mu m(-1) (Bragg peak), 27 keV mu m(-1) (10% peak dose). Alignment of the proton beam with the SARRP system isocenter was measured at 0.24 mm agreement. The width of the beam changes very little with depth. Monte Carlo-based calculations of dose using the CT image data set as input demonstrate in vivo use. Monte Carlo simulations of the modulated 100 MeV clinical proton beam show a significantly reduced Bragg peak. We demonstrate the feasibility of a proton beam integrated with a commercial x-ray image-guidance system for preclinical in vivo studies. To our knowledge this is the first description of an experimental image-guided proton beam for preclinical radiobiology research. It will enable in vivo investigations of radiobiological effects in proton beams.
引用
收藏
页码:43 / 58
页数:16
相关论文
共 72 条
  • [61] Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and 60Co γ-rays
    Vadrucci, M.
    Esposito, G.
    Ronsivalle, C.
    Cherubini, R.
    Marracino, F.
    Montereali, R. M.
    Picardi, L.
    Piccinini, M.
    Pimpinella, M.
    Vincenti, M. A.
    De Angelis, C.
    [J]. MEDICAL PHYSICS, 2015, 42 (08) : 4678 - 4684
  • [62] DOSE-VOLUME EFFECTS IN THE SPINAL-CORD
    VANDERKOGEL, AJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 105 - 109
  • [63] Radiochromic film dosimetry for clinical proton beams
    Vatnitsky, SM
    [J]. APPLIED RADIATION AND ISOTOPES, 1997, 48 (05) : 643 - 651
  • [64] Small animal radiotherapy research platforms
    Verhaegen, Frank
    Granton, Patrick
    Tryggestad, Erik
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (12) : R55 - R83
  • [65] A novel high resolution micro-radiotherapy system for small animal irradiation for cancer research
    Wang, Sigen
    Liu, Zhijun
    Sultana, Shabana
    Schreiber, Eric
    Zhou, Otto
    Chang, Sha
    [J]. BIOFACTORS, 2007, 30 (04) : 265 - 270
  • [66] Assessment of MRI Parameters as Imaging Biomarkers for Radiation Necrosis in the Rat Brain
    Wang, Silun
    Tryggestad, Erik
    Zhou, Tingting
    Armour, Michael
    Wen, Zhibo
    Fu, De-Xue
    Ford, Eric
    van Zijl, Peter C. M.
    Zhou, Jinyuan
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (03): : E431 - E436
  • [67] High-resolution, small animal radiation research platform with X-ray tomographic guidance capabilities
    Wong, John
    Armour, Elwood
    Kazanzides, Peter
    Iordachita, Ulian
    Tryggestad, Erik
    Deng, Hua
    Matinfar, Mohammad
    Kennedy, Christopher
    Liu, Zejian
    Chan, Timothy
    Gray, Owen
    Verhaegen, Frank
    McNutt, Todd
    Ford, Eric
    DeWeese, Theodore L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (05): : 1591 - 1599
  • [68] Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device
    Zarghami, Niloufar
    Jensen, Michael D.
    Talluri, Srikanth
    Foster, Paula J.
    Chambers, Ann F.
    Dick, Frederick A.
    Wong, Eugene
    [J]. MEDICAL PHYSICS, 2015, 42 (11) : 6507 - 6513
  • [69] Anti-PD-1 Blockade and Stereotactic Radiation Produce Long-Term Survival in Mice With Intracranial Gliomas
    Zeng, Jing
    See, Alfred P.
    Phallen, Jillian
    Jackson, Christopher M.
    Belcaid, Zineb
    Ruzevick, Jacob
    Durham, Nicholas
    Meyer, Christian
    Harris, Timothy J.
    Albesiano, Emilia
    Pradilla, Gustavo
    Ford, Eric
    Wong, John
    Hammers, Hans-Joerg
    Mathios, Dimitris
    Tyler, Betty
    Brem, Henry
    Tran, Phuoc T.
    Pardoll, Drew
    Drake, Charles G.
    Lim, Michael
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (02): : 343 - 349
  • [70] Gafchromic EBT film dosimetry in proton beams
    Zhao, Li
    Das, Indra J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (10) : N291 - N301