An image-guided precision proton radiation platform for preclinical in vivo research

被引:39
作者
Ford, E. [1 ]
Emery, R. [1 ]
Huff, D. [1 ]
Narayanan, M. [1 ]
Schwartz, J. [1 ]
Cao, N. [1 ]
Meyer, J. [1 ]
Rengan, R. [1 ]
Zeng, J. [1 ]
Sandison, G. [1 ]
Laramore, G. [1 ]
Mayr, N. [1 ]
机构
[1] Univ Washington, Dept Radiat Oncol, Seattle, WA 98195 USA
关键词
proton therapy; radiobiology; preclinical; image-guidance; RADIOCHROMIC FILM DOSIMETRY; RELATIVE BIOLOGICAL EFFECTIVENESS; INDUCED LUNG INJURY; CRANIAL IRRADIATION; GENE-EXPRESSION; HIGH-RESOLUTION; GROWTH DELAY; MONTE-CARLO; BEAM; MODEL;
D O I
10.1088/1361-6560/62/1/43
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
There are many unknowns in the radiobiology of proton beams and other particle beams. We describe the development and testing of an image-guided low-energy proton system optimized for radiobiological research applications. A 50 MeV proton beam from an existing cyclotron was modified to produce collimated beams (as small as 2 mm in diameter). Ionization chamber and radiochromic film measurements were performed and benchmarked with Monte Carlo simulations (TOPAS). The proton beam was aligned with a commercially-available CT image-guided x-ray irradiator device (SARRP, Xstrahl Inc.). To examine the alternative possibility of adapting a clinical proton therapy system, we performed Monte Carlo simulations of a range-shifted 100 MeV clinical beam. The proton beam exhibits a pristine Bragg Peak at a depth of 21 mm in water with a dose rate of 8.4 Gy min(-1) (3 mm depth). The energy of the incident beam can be modulated to lower energies while preserving the Bragg peak. The LET was: 2.0 keV mu m(-1) (water surface), 16 keV mu m(-1) (Bragg peak), 27 keV mu m(-1) (10% peak dose). Alignment of the proton beam with the SARRP system isocenter was measured at 0.24 mm agreement. The width of the beam changes very little with depth. Monte Carlo-based calculations of dose using the CT image data set as input demonstrate in vivo use. Monte Carlo simulations of the modulated 100 MeV clinical proton beam show a significantly reduced Bragg peak. We demonstrate the feasibility of a proton beam integrated with a commercial x-ray image-guidance system for preclinical in vivo studies. To our knowledge this is the first description of an experimental image-guided proton beam for preclinical radiobiology research. It will enable in vivo investigations of radiobiological effects in proton beams.
引用
收藏
页码:43 / 58
页数:16
相关论文
共 72 条
  • [21] A Longitudinal Evaluation of Partial Lung Irradiation in Mice by Using a Dedicated Image-Guided Small Animal Irradiator
    Granton, Patrick V.
    Dubois, Ludwig
    van Elmpt, Wouter
    van Hoof, Stefan J.
    Lieuwes, Natasja G.
    De Ruysscher, Dirk
    Verhaegen, Frank
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 (03): : 696 - 704
  • [22] Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner
    Graves, Edward E.
    Zhou, Hu
    Chatterjee, Raja
    Keall, Paul J.
    Gambhir, Sanjiv Sam
    Contag, Christopher H.
    Boyer, Arthur L.
    [J]. MEDICAL PHYSICS, 2007, 34 (11) : 4359 - 4367
  • [23] Scanning irradiation device for mice in vivo with pulsed and continuous proton beams
    Greubel, Christoph
    Assmann, Walter
    Burgdorf, Christian
    Dollinger, Guenther
    Du, Guanghua
    Hable, Volker
    Hapfelmeier, Alexander
    Hertenberger, Ralf
    Kneschaurek, Peter
    Michalski, Doerte
    Molls, Michael
    Reinhardt, Sabine
    Roeper, Barbara
    Schell, Stefan
    Schmid, Thomas E.
    Siebenwirth, Christian
    Wenzl, Tatiana
    Zlobinskaya, Olga
    Wilkens, Jan J.
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2011, 50 (03) : 339 - 344
  • [24] A community call for a dedicated radiobiological research facility to support particle beam cancer therapy
    Holzscheiter, Michael H.
    Bassler, Niels
    Dosanjh, Manjit
    Sorensen, Brita Singers
    Overgaard, Jens
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 105 (01) : 1 - 3
  • [25] An Experimental Model-Based Exploration of Cytokines in Ablative Radiation-Induced Lung Injury In Vivo and In Vitro
    Hong, Zhen-Yu
    Song, Kwang Hyun
    Yoon, Joo-Heon
    Cho, Jaeho
    Story, Michael D.
    [J]. LUNG, 2015, 193 (03) : 409 - 419
  • [26] A Preclinical Rodent Model of Acute Radiation-Induced Lung Injury after Ablative Focal Irradiation Reflecting Clinical Stereotactic Body Radiotherapy
    Hong, Zhen-Yu
    Lee, Hae-June
    Choi, Won Hoon
    Lee, Yoon-Jin
    Eun, Sung Ho
    Lee, Jung Il
    Park, Kwangwoo
    Lee, Ji Min
    Cho, Jaeho
    [J]. RADIATION RESEARCH, 2014, 182 (01) : 83 - 91
  • [27] IAEA, 2004, Absorbed Dose Determination in External Beam Radiotherapy: an International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water
  • [28] Estimation of optimum dose per fraction for high let radiations: Implications for proton radiotherapy
    Jones, B
    Dale, RG
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05): : 1549 - 1557
  • [29] Hematopoietic Stem and Progenitor Cell Migration After Hypofractionated Radiation Therapy in a Murine Model
    Kane, Jonathan
    Krueger, Sarah A.
    Dilworth, Joshua T.
    Torma, John T.
    Wilson, George D.
    Marples, Brian
    Madlambayan, Gerard J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (05): : 1162 - 1170
  • [30] Depth absorbed dose and LET distributions of therapeutic 1H, 4He, 7Li, and 12C beams
    Kempe, Johanna
    Gudowska, Irena
    Brahme, Anders
    [J]. MEDICAL PHYSICS, 2007, 34 (01) : 183 - 192