Effect of Doppler flow meter position on discharge measurement in surcharged manholes

被引:2
作者
Yang, Haoming [1 ,2 ]
Zhu, David Z. [1 ,2 ]
Liu, Yanchen [3 ]
机构
[1] Zhejiang Univ, Dept Civil Engn, Hangzhou 310027, Zhejiang, Peoples R China
[2] Univ Alberta, Dept Civil & Environm Engn, Edmonton, AB T6G 2W2, Canada
[3] Tsinghua Univ, Sch Environm, State Key Joint Lab Environm Simulat & Pollut Con, Beijing 100084, Peoples R China
基金
中国国家自然科学基金; 加拿大自然科学与工程研究理事会;
关键词
CFD; Doppler flow meter; flow rate; installation; surcharged manholes; CHARACTERIZE;
D O I
10.2166/wst.2017.563
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Determining the proper installation location of flow meters is important for accurate measurement of discharge in sewer systems. In this study, flow field and flow regimes in two types of manholes under surcharged flow were investigated using a commercial computational fluid dynamics (CFD) code. The error in measuring the flow discharge using a Doppler flow meter (based on the velocity in a Doppler beam) was then estimated. The values of the corrective coefficient were obtained for the Doppler flow meter at different locations under various conditions. Suggestions for selecting installation positions are provided.
引用
收藏
页码:647 / 654
页数:8
相关论文
共 22 条
  • [1] [Anonymous], 2014, 0265280408 HACH
  • [2] Experimental and computational study of velocity fields in narrow or compound section sewers
    Bonakdari, H.
    Larrarte, F.
    Bardiaux, J-B.
    [J]. WATER PRACTICE AND TECHNOLOGY, 2007, 2 (02):
  • [3] Bonakdari H., 2011, WORLD ENV WAT RES C
  • [5] Influence of position and type of Doppler flow meters on flow-rate measurement in sewers using computational fluid dynamic
    Bonakdari, Hossein
    Zinatizadeh, Ali Akbar
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2011, 22 (03) : 225 - 234
  • [6] Ferziger JH., 1996, COMPUTATIONAL METHOD
  • [7] Guymer I., 2011, 12 INT C URB DRAIN P
  • [8] Hach, 2016, 0269780186 HACH
  • [9] Analysis of installation effects by means of computational fluid dynamics - CFD vs experiments?
    Hilgenstock, A
    Ernst, R
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 1996, 7 (3-4) : 161 - 171
  • [10] Acoustic Doppler flow-meters: A proposal to characterize their technical parameters
    Larrarte, Frederique
    Bardiaux, Jean Bernard
    Battaglia, Philippe
    Joannis, Claude
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2008, 19 (05) : 261 - 267