On the Potential of Bulk Metallic Glasses for Dental Implantology: Case Study on Ti40Zr10Cu36Pd14

被引:42
|
作者
Liens, Alethea [1 ,2 ]
Etiemble, Aurelien [1 ]
Rivory, Pascaline [1 ]
Balvay, Sandra [1 ]
Pelletier, Jean-Marc [1 ]
Cardinal, Sandrine [1 ]
Fabregue, Damien [1 ]
Kato, Hidemi [3 ]
Steyer, Philippe [1 ]
Munhoz, Tais [1 ]
Adrien, Jerome [1 ]
Courtois, Nicolas [2 ]
Hartmann, Daniel J. [1 ]
Chevalier, Jerome [1 ]
机构
[1] Univ Lyon, UMR CNRS 5510, MATEIS Lab, INSA Lyon, 20 Ave Albert Einstein, F-69621 Villeurbanne, France
[2] Anthogyr SAS, 2237 Ave A Lasquin, F-74700 Sallanches, France
[3] Tohoku Univ, Inst Mat Res, Sendai, Miyagi 980011, Japan
关键词
Ti-based bulk metallic glass; biomaterials; dental application; mechanical properties; biocompatibility; MECHANICAL-PROPERTIES; IN-VITRO; FORMING ABILITY; CORROSION BEHAVIOR; AMORPHOUS-ALLOYS; NI; BIOCOMPATIBILITY; FABRICATION; VIVO;
D O I
10.3390/ma11020249
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Ti40Zr10Cu36Pd14 Bulk Metallic Glass (BMG) appears very attractive for future biomedical applications thanks to its high glass forming ability, the absence of toxic elements such as Ni, Al or Be and its good mechanical properties. For the first time, a complete and exhaustive characterization of a unique batch of this glassy alloy was performed, together with ISO standard mechanical tests on machined implant-abutment assemblies. The results were compared to the benchmark Ti-6Al-4V ELI (Extra-Low-Interstitial) to assess its potential in dental implantology. The thermal stability, corrosion and sterilization resistance, cytocompatibility and mechanical properties were measured on samples with a simple geometry, but also on implant-abutment assemblies' prototypes. Results show that the glassy alloy exhibits a quite high thermal stability, with a temperature range of 38 degrees C between the glass transition and crystallization, a compressive strength of 2 GPa, a certain plastic deformation (0.7%), a hardness of 5.5 GPa and a toughness of 56 MPa.m. Moreover, the alloy shows a relatively lower Young's modulus (96 GPa) than the Ti-6Al-4V alloy (110-115 GPa), which is beneficial to limit bone stress shielding. The BMG shows a satisfactory cytocompatibility, a high resistance to sterilization and a good corrosion resistance (corrosion potential of -0.07 V/SCE and corrosion current density of 6.0 nA/cm(2)), which may ensure its use as a biomaterial. Tests on dental implants reveal a load to failure 1.5-times higher than that of Ti-6Al-4V and a comparable fatigue limit. Moreover, implants could be machined and sandblasted by methods usually conducted for titanium implants, without significant degradation of their amorphous nature. All these properties place this metallic glass among a promising class of materials for mechanically-challenging applications such as dental implants.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Antibacterial activity, cytocompatibility, and thermomechanical stability of Ti40Zr10Cu36Pd14 bulk metallic glass
    Rezvan, Amir
    Sharifikolouei, Elham
    Lassnig, Alice
    Soprunyuk, Viktor
    Gammer, Christoph
    Spieckermann, Florian
    Schranz, Wilfried
    Najmi, Ziba
    Cochis, Andrea
    Scalia, Alessandro Calogero
    Rimondini, Lia
    Manfredi, Marcello
    Eckert, Jurgen
    Sarac, Baran
    MATERIALS TODAY BIO, 2022, 16
  • [2] Modification of structural, mechanical, corrosion and biocompatibility properties of Ti40Zr10Cu36Pd14 metallic glass by minor Ga and Sn additions
    Lachova, Andrea
    Stoica, Mihai
    Michalik, Stefan
    Gostin, Petre F.
    Fujioka-Kobayashi, Masako
    Schaller, Benoit
    Loeffler, Joerg F.
    Sovak, Pavol
    JOURNAL OF ALLOYS AND COMPOUNDS, 2023, 940
  • [3] The Effects of Cooling Rate on the Microstructure and Mechanical Properties of Ti40Zr10Cu36Pd14 Metallic Glass Matrix Composites
    Park, Seon Yong
    Lim, Ka Ram
    Na, Young Sang
    Kim, Seong Eon
    Choi, Youn Suk
    Korean Journal of Metals and Materials, 2016, 54 (11): : 802 - 807
  • [4] Insights into the crystallisation pathways in as-cast Ti40Zr10Cu36Pd14 glassy alloys
    Douest, Yohan
    Cazottes, Sophie
    Costa, Miguel B.
    Ter-Ovanessian, Benoit
    Courtois, Nicolas
    Chevalier, Jerome
    Greer, A. Lindsay
    Fabregue, Damien
    MATERIALS CHARACTERIZATION, 2024, 214
  • [5] Properties of the Ti40Zr10Cu36Pd14 BMG Modified by Sn and Nb Additions
    Sypien, Anna
    Stoica, Mihail
    Czeppe, Tomasz
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2016, 25 (03) : 800 - 808
  • [6] In vitro corrosion and biocompatibility screening of sputtered Ti40Cu36Pd14Zr10 thin film metallic glasses on steels
    Subramanian, B.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 47 : 48 - 56
  • [7] Formation and properties of Ti-based Ti-Zr-Cu-Fe-Sn-Si bulk metallic glasses with different (Ti plus Zr)/Cu ratios for biomedical application
    Liu, Ying
    Pang, Shujie
    Li, Haifei
    Hu, Qiao
    Chen, Bin
    Zhang, Tao
    INTERMETALLICS, 2016, 72 : 36 - 43
  • [8] Formation and properties of centimeter-size Zr-Ti-Cu-Al-Y bulk metallic glasses as potential biomaterials
    Zhou, Kun
    Liu, Ying
    Pang, Shujie
    Zhang, Tao
    JOURNAL OF ALLOYS AND COMPOUNDS, 2016, 656 : 389 - 394
  • [9] Impact of spherulite-type crystalline defects on the mechanical and electrochemical properties of Ti40Cu36Zr10Pd14 metallic glasses
    Gautier, Laurabelle
    Liens, Alethea
    Ter-Ovanessian, Benoit
    Marcelin, Sabrina
    Douillard, Thierry
    Richard, Herve
    Courtois, Nicolas
    Chevalier, Jerome
    Fabregue, Damien
    MATERIALIA, 2022, 21
  • [10] Application of Zr and Ti-Based Bulk Metallic Glasses for Orthopaedic and Dental Device Materials
    Imai, Kazuhiro
    Zhou, Xiao
    Liu, Xiaoxuan
    METALS, 2020, 10 (02)