The isolated perfused ''working'' rat heart: A new method

被引:5
作者
Igic, R
机构
[1] Anesthesiology Research Laboratory, Dept. of Anesth. and Pain Management, Cook County Hospital, Chicago, IL
[2] Anesthesiology Research Laboratory, Chicago, IL 60612
关键词
isolated heart; ''working'' heart model; yohimbine-induced dysrhythmias; rat;
D O I
10.1016/1056-8719(96)00001-9
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
This paper presents a ''working'' isolated perfused rat heart. A special double cannula was designed consisting of an outer cannula that is inserted in the aorta and an inner cannula that is advanced into the left ventricle. The perfusion fluid flows through the inner cannula into the left ventricle, and is ejected from there into the aorta. If the outer cannula system is closed, the fluid perfuses the coronary vessels and drips off outside the heart. When the outer cannula is open and certain pressure resistance is applied, a fraction of the ejected fluid perfuses coronary vessels and the rest is expelled. Because the inner cannula can easily be retracted into the outer cannula, which is placed in the aorta, this preparation provides an opportunity to use the same heart as a ''working'' or ''non-working'' model for investigating functions of the heart. The effects of epinephrine and yohimbine were tested on this model. This preparation is simple, durable, and reliable.
引用
收藏
页码:63 / 67
页数:5
相关论文
共 11 条
  • [1] RELATIONSHIP BETWEEN MYOCARDIAL OXYGEN-CONSUMPTION, CORONARY FLOW, AND ADENOSINE RELEASE IN AN IMPROVED ISOLATED WORKING HEART PREPARATION OF GUINEA-PIGS
    BARDENHEUER, H
    SCHRADER, J
    [J]. CIRCULATION RESEARCH, 1983, 52 (03) : 263 - 271
  • [2] LANGENDORFF HEART PREPARATION - REAPPRAISAL OF ITS ROLE AS A RESEARCH AND TEACHING MODEL FOR CORONARY VASOACTIVE DRUGS
    BROADLEY, KJ
    [J]. JOURNAL OF PHARMACOLOGICAL METHODS, 1979, 2 (02): : 143 - 156
  • [3] AN IMPROVED PERFUSION APPARATUS FOR SMALL ANIMAL HEARTS
    CURTIS, MJ
    MACLEOD, BA
    TABRIZCHI, R
    WALKER, MJA
    [J]. JOURNAL OF PHARMACOLOGICAL METHODS, 1986, 15 (01): : 87 - 94
  • [4] DORING HJ, 1988, ISOLATED PERFUSED HE, P83
  • [5] IGIC R, 1995, FASEB J, V9, pA601
  • [6] IGIC R, 1996, IN PRESS CAN J PHYSL, V74
  • [7] APPLICATION OF A PRESSURE SERVO SYSTEM DEVELOPED TO STUDY VENTRICULAR DYNAMICS
    JANICKI, JS
    REEVES, RC
    WEBER, KT
    DONALD, TC
    WALKER, AA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1974, 37 (05) : 736 - 741
  • [8] Langendorff O., 1895, PFLUGERS ARCH GESAMT, V61, P291, DOI [DOI 10.1007/BF01812150, 10.1007/BF01812150]
  • [9] LU FC, 1950, J PHARMACOL EXP THER, V99, P277
  • [10] NEELY JR, 1967, AM J PHYSIOL, V212, P804