A new water-soluble Fe3+ fluorescence sensor with a large Stokes shift based on [5]helicene derivative: Its application in flow injection analysis and biological systems
被引:14
作者:
Petdum, Anuwut
论文数: 0引用数: 0
h-index: 0
机构:
Silpakorn Univ, Fac Sci, Dept Chem, Nakhon Pathom 73000, ThailandSilpakorn Univ, Fac Sci, Dept Chem, Nakhon Pathom 73000, Thailand
Petdum, Anuwut
[1
]
Waraeksiri, Nitchanat
论文数: 0引用数: 0
h-index: 0
机构:
Silpakorn Univ, Fac Sci, Dept Chem, Nakhon Pathom 73000, ThailandSilpakorn Univ, Fac Sci, Dept Chem, Nakhon Pathom 73000, Thailand
Waraeksiri, Nitchanat
[1
]
Hanmeng, Oranual
论文数: 0引用数: 0
h-index: 0
机构:
Silpakorn Univ, Fac Sci, Dept Chem, Nakhon Pathom 73000, ThailandSilpakorn Univ, Fac Sci, Dept Chem, Nakhon Pathom 73000, Thailand
Hanmeng, Oranual
[1
]
Jarutikorn, Suphaluk
论文数: 0引用数: 0
h-index: 0
机构:
Silpakorn Univ, Fac Sci, Dept Chem, Nakhon Pathom 73000, ThailandSilpakorn Univ, Fac Sci, Dept Chem, Nakhon Pathom 73000, Thailand
Jarutikorn, Suphaluk
[1
]
Chaneam, Sumonmarn
论文数: 0引用数: 0
h-index: 0
机构:
Silpakorn Univ, Fac Sci, Dept Chem, Nakhon Pathom 73000, ThailandSilpakorn Univ, Fac Sci, Dept Chem, Nakhon Pathom 73000, Thailand
Chaneam, Sumonmarn
[1
]
Sirirak, Jitnapa
论文数: 0引用数: 0
h-index: 0
机构:
Silpakorn Univ, Fac Sci, Dept Chem, Nakhon Pathom 73000, ThailandSilpakorn Univ, Fac Sci, Dept Chem, Nakhon Pathom 73000, Thailand
Sirirak, Jitnapa
[1
]
论文数: 引用数:
h-index:
机构:
Charoenpanich, Adisri
[2
]
Panchan, Waraporn
论文数: 0引用数: 0
h-index: 0
机构:
Natl Met & Mat Technol Ctr MTEC, Pathum Thani 12120, ThailandSilpakorn Univ, Fac Sci, Dept Chem, Nakhon Pathom 73000, Thailand
Panchan, Waraporn
[3
]
Sooksimuang, Thanasat
论文数: 0引用数: 0
h-index: 0
机构:
Natl Met & Mat Technol Ctr MTEC, Pathum Thani 12120, ThailandSilpakorn Univ, Fac Sci, Dept Chem, Nakhon Pathom 73000, Thailand
A new Fe3+ fluorescence sensor (M141) was successfully synthesized by conjugating a [5]helicene derivative with 1,3-propanesultone. M141 exhibited highly sensitive fluorescence quenching in the presence of Fe3+ with an extremely large Stokes shift of 192 nm which could reduce the analytical error. M141 also permitted the highly selective detection of Fe3+ over other competitive metal ions in aqueous buffer solution at physiological pH. The sensor had ability to dissolve in water which could benefit for the application involved biological system. Additionally, M141 was used to identify Fe3+ in human cancer cells and combined with flow injection analysis (FIA) to develop a method for potentially rapid Fe3+ determination with samples throughput of 30 samples h(-1).