Radiation dose of coronary CT angiography with a third-generation dual-source CT in a "real-world" patient population

被引:37
作者
Kosmala, Aleksander [1 ]
Petritsch, Bernhard [1 ]
Weng, Andreas Max [1 ]
Bley, Thorsten Alexander [1 ]
Gassenmaier, Tobias [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacherstr 6, D-97080 Wurzburg, Germany
关键词
Computed tomography angiography; Radiation dosage; Coronary artery disease; Heart rate; Body mass index; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; TUBE VOLTAGE; K-EDGE; GUIDELINES; EXPOSURE; PROTOCOLS; IMPACT;
D O I
10.1007/s00330-018-5856-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesTo assess radiation dose and image quality of coronary computed tomography angiography (cCTA) with a third-generation dual-source scanner in a real-world patient population.MethodsScans of otherwise unselected, consecutive patients referred for clinically indicated cCTA between June 2015 and November 2017 were included for retrospective analysis. Scan protocol was based on heart rate: prospectively ECG-gated high-pitch spiral below 60 beats per minute (bpm), prospectively ECG-gated sequential scan between 61 and 70bpm, and retrospective spiral above 70bmp or at irregular heart rates. Objective image quality was measured as signal-to-noise (SNR) and contrast-to-noise ratio (CNR); subjective image quality was evaluated using a five-point Likert scale by two independent readers. For radiation dose analysis, effective dose, size-specific dose estimates, and volume CT dose index were assessed.ResultsTwo hundred seventy-eight patients (median age, 60years; 155 men) with a median body mass index of 26.6kg/m(2) (range, 16.7-60.9kg/m(2); 180 (64.7%) overweight or obese) were included (122 in the high-pitch spiral group, 60 in the prospective sequence group, and 96 in the retrospective spiral group). Median effective dose was 0.63mSv (interquartile range [IQR], 0.51-0.90mSv) for high-pitch spiral, 1.32mSv (IQR, 0.79-2.46mSv) for prospective sequence, and 4.77 (IQR, 3.02-8.27mSv) for retrospective spiral (p<0.001). Most studies had at least very good image quality (91.4/88.8% R1/R2), with highest SNR and CNR in the high-pitch spiral group.ConclusionscCTA with sufficient image quality is achievable at reasonably low radiation exposure in a real-world patient collective with a high proportion of overweight or obese patients.Key Points center dot Submillisievert radiation dose coronary CT angiography with good diagnostic image quality is feasible in the majority of cases in a real-world patient using high-pitch spiral.center dot Prospective sequence results in about double median effective dose compared to the high-pitch protocol.center dot To optimize individual radiation exposure, lowering the heart rate is paramount, as it allows for choosing a dose-optimized (high-pitch spiral) scan protocol.
引用
收藏
页码:4341 / 4348
页数:8
相关论文
共 34 条
[1]  
Abbara Suhny, 2009, J Cardiovasc Comput Tomogr, V3, P190, DOI 10.1016/j.jcct.2009.03.004
[2]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[3]  
[Anonymous], ANN ICRP
[4]   Impact on Image Quality and Radiation Dose of Third-Generation Dual-Source Computed Tomography of the Coronary Arteries [J].
Apfaltrer, Georg ;
Szolar, Dieter H. ;
Wurzinger, Eric ;
Takx, Richard A. P. ;
Nance, John W. ;
Dutschke, Anja ;
Tschauner, Sebastian ;
Loewe, Christian ;
Ringl, Helmut ;
Sorantin, Erich ;
Apfaltrer, Paul .
AMERICAN JOURNAL OF CARDIOLOGY, 2017, 119 (08) :1156-1161
[5]   Impact of a Reduced Tube Voltage on CT Angiography and Radiation Dose Results of the PROTECTION I Study [J].
Bischoff, Bernhard ;
Hein, Franziska ;
Meyer, Tanja ;
Hadamitzky, Martin ;
Martinoff, Stefan ;
Schoemig, Albert ;
Hausleiter, Joerg .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (08) :940-946
[6]  
Boone J.M., 2011, SIZE SPECIFIC DOSE E
[7]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[8]   Radiation and contrast agent doses reductions by using 80-kV tube voltage in coronary computed tomographic angiography: A comparative study [J].
Cao, Jian-xin ;
Wang, Yi-min ;
Lu, Jin-guo ;
Zhang, Yu ;
Wang, Peng ;
Yang, Cheng .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) :309-314
[9]   Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323
[10]   Effects of Radiation Exposure From Cardiac Imaging How Good Are the Data? [J].
Einstein, Andrew J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (06) :553-565