Comparison Between the New Gore Septal and Amplatzer Devices For Transcatheter Closure of Patent Foramen Ovale - Short- and Mid-Term Clinical and Echocardiographic Outcomes

被引:18
作者
Musto, Carmine [1 ]
Cifarelli, Alberta [1 ]
Fiorilli, Rosario [1 ]
De Felice, Francesco [1 ]
Parma, Antonio [1 ]
Nazzaro, Marco Stefano [1 ]
Guerra, Elena [1 ]
Fiorilli, Francesca [1 ]
Violini, Roberto [1 ]
机构
[1] San Camillo Hosp, Intervent Cardiol Unit, I-00152 Rome, Italy
关键词
Gore septal occluder; Patent foramen ovate; Right-to left shunting; TERM-FOLLOW-UP; PERCUTANEOUS CLOSURE; PARADOXICAL EMBOLISM; OCCLUDER; ANEURYSM;
D O I
10.1253/circj.CJ-13-0565
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The ideal device for percutaneous patent foramen ovate (PFO) occlusion should provide effective closure with long-term biocompatibility and it should have a low profile without interfering with adjacent cardiac structures. Long-term data regarding safety and efficacy of the GORE Septal Occluder (GSO) are lacking. The aim of this study was to investigate the short- and mid-term clinical and echocardiographic outcomes of this device. Methods and Results: Forty-five consecutive patients with clinically significant PFO were treated with GSO and their results were compared with those of 45 consecutive patients treated with Amplatzer PFO device (APO). Primary endpoint was the incidence of 6-month residual right-to-left shunting (rRLS). The procedural results and the recurrence of embolic events (REE) at 1 year were also investigated. No differences in terms of embolic risk profile and echocardiographic parameters were observed between the 2 groups. GSO was successfully implanted in all patients without device-related complication. In 2 patients for whom device position was not optimal, the GSO was easily retrieved and a new GSO was successfully repositioned. Immediate moderate severe rRLS was similar in 2 groups. No cases of severe 6-month rRLS were registered. Two patients (4%) and 1 patient (2%) had moderate 6-month rRLS in the GSO and APO group, respectively (P=NS). No cases of REE were registered at 1-year follow-up. Conclusions: GSO appears a valuable alternative to Amplatzer device for PFO occlusion.
引用
收藏
页码:2922 / 2927
页数:6
相关论文
共 17 条
[1]   Late cardiac perforation after transcatheter closure of patent foramen ovale [J].
Cecconi, M ;
Quarti, A ;
Bianchini, F ;
Bucari, S ;
Costantini, C ;
Giovagnoni, A ;
Perna, GP .
ANNALS OF THORACIC SURGERY, 2006, 81 (06) :E29-E30
[2]   Long-term outcome of transcatheter patent foramen ovale closure in patients with paradoxical embolism [J].
Cifarelli, Alberta ;
Musto, Carmine ;
Parma, Antonio ;
Pandolfi, Claudia ;
Pucci, Edoardo ;
Fiorilli, Rosario ;
De Felice, Francesco ;
Nazzaro, Marco Stefano ;
Violini, Roberto .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 141 (03) :304-310
[3]   Fracture of the GORE HELEX Septal Occluder: Associated Factors and Clinical Outcomes [J].
Fagan, Thomas ;
Dreher, Dennis ;
Cutright, Warren ;
Jacobson, Joth ;
Latson, Larry .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (07) :941-948
[4]  
Hideaki U, 2012, CIRC J, V76, P1229
[5]   Eight-French Intracardiac Echocardiography - Safe and Effective Guidance for Transcatheter Closure in Atrial Septal Defects [J].
Kim, Nam Kyun ;
Park, Su-Jin ;
Shin, Jae Il ;
Choi, Jae Young .
CIRCULATION JOURNAL, 2012, 76 (09) :2119-2123
[6]   Initial use of the new GORE® septal occluder in patent foramen ovale closure: Implantation and preliminary results [J].
MacDonald, Simon T. ;
Daniels, Matthew J. ;
Ormerod, Oliver J. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (04) :660-665
[7]  
MacDonald ST, 2010, EXPERT REV CARDIOVAS, V8, P1741, DOI [10.1586/erc.10.165, 10.1586/ERC.10.165]
[8]   Percutaneous transcatheter closure of patent foramen ovale in patients with paradoxical embolism [J].
Martín, F ;
Sánchez, PL ;
Doherty, E ;
Colon-Hernandez, PJ ;
Delgado, G ;
Inglessis, I ;
Scott, N ;
Hung, J ;
King, MEE ;
Buonanno, F ;
Demirjian, Z ;
de Moor, M ;
Palacios, IF .
CIRCULATION, 2002, 106 (09) :1121-1126
[9]   A Biodegradable Device (BioSTAR™) for Atrial Septal Defect Closure in Children [J].
Morgan, Gareth ;
Lee, Kyong-Jin ;
Chaturvedi, Rajiv ;
Benson, Lee .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (02) :241-245
[10]  
Musto C, 2012, J INVASIVE CARDIOL, V24, P510