Dispersive liquid-liquid microextraction (DLLME); High-performance liquid chromatography; Sample preparation; Chloramphenicol; Thiamphenicol; Honey sample; PLASMON RESONANCE BIOSENSOR; GAS-CHROMATOGRAPHY; PHASE MICROEXTRACTION; MASS-SPECTROMETRY; ORGANOPHOSPHORUS PESTICIDES; SAMPLE PREPARATION; ARRAY DETECTION; ANIMAL-TISSUES; SINGLE DROP; RESIDUES;
D O I
10.1016/j.aca.2008.10.068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detector (HPLC-VWD) was developed for extraction and determination of chloramphenicol (CAP) and thiamphenicol (THA) in honey. In this extraction method, 1.0mL of aceronitrile (as dispersive solvent) containing 30 mu L 1,1,2,2-tetrachloroethane (as extraction solution) was rapidly injected by syringe into a 5.00-mL water sample containing the analytes, thereby forming a cloudy solution. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by HPLC-VWD. Some important parameters, such as the nature and volume of extraction solvent and dispersive solvent, extraction time, sample solution pH, sample volume and salt effect were investigated and optimized. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 3 to 2000 mu g kg(-1) for target analytes. The enrichment factors for CAP and THA were 68.2 and 87.9, and the limits of detection (S/N = 3) were 0.6 and 0.1 mu g kg(-1), respectively. The relative standard deviations (RSDs) for the extraction of 10 mu g kg(-1) of CAP and THA were 4.3% and 6.2% (n = 6). The main advantages of DLLME-HPLC method are simplicity of operation, rapidity, low cost, high enrichment factor, high recovery, good repeatability and extraction solvent volume at microliter level. Honey samples were successfully analyzed using the proposed method. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 30 条
[1]   Determination of organophosphorus pesticides in water samples by single drop microextraction and gas chromatography-flame photometric detector [J].
Ahmadi, F ;
Assadi, Y ;
Hosseini, SMRM ;
Rezaee, M .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) :307-312
[2]  
[Anonymous], TRENDS ANAL CHEM
[3]  
ARNOLD D, 1985, J ASSOC OFF ANA CHEM, V68, P984
[4]   Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water [J].
Berijani, Sana ;
Assadi, Yaghoub ;
Anbia, Mansoor ;
Milani Hosseini, Mohammad-Reza ;
Aghaee, Elham .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) :1-9
[5]   Application of on-line solid-phase extraction-gas chromatography-mass spectrometry to the determination of endocrine disruptors in water samples [J].
Brossa, L ;
Marcé, RM ;
Borrull, F ;
Pocurull, E .
JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) :287-294
[6]   Modified pencil lead as a new fiber for solid-phase microextraction [J].
Djozan, D ;
Assadi, Y .
CHROMATOGRAPHIA, 2004, 60 (5-6) :313-317
[7]   Anodized aluminum wire as a solid-phase microextraction fiber [J].
Djozan, D ;
Assadi, Y ;
Haddadi, SH .
ANALYTICAL CHEMISTRY, 2001, 73 (16) :4054-4058
[8]   A surface plasmon resonance biosensor assay for the simultaneous determination of thiamphenicol, florefenicol, florefenicol amine and chloramphenicol residues in shrimps [J].
Dumont, V. ;
Huet, A. -C. ;
Traynor, I. ;
Elliott, C. ;
Delahaut, P. .
ANALYTICA CHIMICA ACTA, 2006, 567 (02) :179-183
[9]   Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection as an efficient and sensitive technique for determination of antioxidants [J].
Farajzadeh, Mir Ali ;
Bahram, Morteza ;
Jonsson, Jan Ake .
ANALYTICA CHIMICA ACTA, 2007, 591 (01) :69-79
[10]   Determination of volatile phenols in red wines by dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry detection [J].
Farina, Laura ;
Boido, Eduardo ;
Carrau, Francisco ;
Dellacassa, Eduardo .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) :46-50