Oil-filled polymer microcapsules for ultrasound-mediated delivery of lipophilic drugs

被引:95
作者
Kooiman, Klazina [1 ]
Bohmer, Marcel R. [2 ]
Emmer, Marcia [1 ]
Vos, Hendrik J. [1 ]
Chlon, Ceciel [2 ]
Shi, William T. [3 ]
Hall, Christopher S. [3 ]
de Winter, Suzanne H. P. M. [2 ]
Schroen, Karin [4 ]
Versluis, Michel [5 ]
de Jong, Nico [1 ,5 ,6 ]
van Wamel, Annemieke [1 ]
机构
[1] Erasmus MC, Dept Biomed Engn, NL-3000 CA Rotterdam, Netherlands
[2] Philips Res Labs, Eindhoven, Netherlands
[3] Philips Res Labs N Amer, Briarcliff Manor, NY USA
[4] Univ Wageningen & Res Ctr, Dept Agrotechnol & Food Sci, Food & Bioproc Engn Grp, Wageningen, Netherlands
[5] Univ Twente, Phys Fluids Grp, NL-7500 AE Enschede, Netherlands
[6] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
关键词
Ultrasound contrast agent; Polymer-shelled microcapsule; Acoustic properties; Drug delivery; Lipophilic drug; MICROBUBBLE CONTRAST AGENTS; THERAPEUTIC APPLICATIONS; MICROSPHERES; GENE; PACLITAXEL; DYNAMICS; RELEASE; PLA;
D O I
10.1016/j.jconrel.2008.09.085
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The use of ultrasound contrast agents as local drug delivery systems Continues to grow. Current limitations are the amount of drug that can be incorporated as well as the efficiency of drug release Upon insonification. This Study focuses oil the synthesis and characterisation of novel polymeric microcapsules for ultrasound-triggered delivery of lipophilic drugs. Microcapsules with a shell Of fluorinated end-capped poly(L-lactic acid) were made through pre-mix membrane emulsification and contained, apart from a gaseous phase, different amounts of hexadecane oil as a drug-carrier reservoir. Mean number weighted diameters were between 1.22 mu m and 1.31 mu m. High-speed imaging at similar to 10 million fames per second showed that for low acoustic pressures (1 MHz, 0.24 MPa) microcapsules compressed but remained intact. At higher diagnostic pressures of 0.51 MPa, microcapsules cracked, thereby releasing the encapsulated gas and model lipophilic drug, U-Sing conventional ultrasound B-mode imaging at a frequency of 2.5 MHz, a marked enhancement of scatter intensity over a tissue-mimicking phantom was observed for all differently loaded microcapsules. The partially oil-filled microcapsules with high drug loads and well-defined acoustic activation thresholds have great potential for ultrasound-triggered local delivery of lipophilic drugs under ultrasound image-guidance. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:109 / 118
页数:10
相关论文
共 48 条
[1]   Biodegradation and biocompatibility of PLA and PLGA microspheres [J].
Anderson, JM ;
Shive, MS .
ADVANCED DRUG DELIVERY REVIEWS, 1997, 28 (01) :5-24
[2]  
[Anonymous], 2012, The Acoustic Bubble
[3]   International recommendations and guidelines for the safe use of diagnostic ultrasound in medicine [J].
Barnett, SB ;
Ter Haar, GR ;
Ziskin, MC ;
Rott, HD ;
Duck, FA ;
Maeda, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (03) :355-366
[4]   Use of ultrasound contrast agents for gene or drug delivery in cardiovascular medicine [J].
Bekeredjian, R ;
Grayburn, PA ;
Shohet, RV .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) :329-335
[5]   Quantitative measurement of ultrasound disruption of polymer-shelled microbubbles [J].
Bevan, Peter D. ;
Karshafian, Raffj ;
Tickner, E. Glenn ;
Burns, Peter N. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (11) :1777-1786
[6]   Preparation of polymeric microbubbles: formulation studies and product characterisation [J].
Bjerknes, K ;
Sontum, PC ;
Smistad, G ;
Agerkvist, I .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1997, 158 (02) :129-136
[7]   Optical observation of lipid- and polymer-shelled ultrasound microbubble contrast agents [J].
Bloch, SH ;
Wan, M ;
Dayton, PA ;
Ferrara, KW .
APPLIED PHYSICS LETTERS, 2004, 84 (04) :631-633
[8]  
BLOEDOW DC, 1978, J PHARM SCI, V65, P328
[9]   Preparation of monodisperse polymer particles and capsules by ink-jet printing [J].
Bohmer, Marcel R. ;
Schroeders, Richard ;
Steenbakkers, Jan A. M. ;
de Winter, Suzanne H. P. M. ;
Duineveld, Paul A. ;
Lub, Johan ;
Nijssen, Wim P. M. ;
Pikkemaat, Jeroen A. ;
Stapert, Henk R. .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2006, 289 (1-3) :96-104
[10]   High-speed optical observations of contrast agent destruction [J].
Bouakaz, A ;
Versluis, M ;
de Jong, N .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (03) :391-399