Anterior Capsulotomy Integrity after Femtosecond Laser-Assisted Cataract Surgery

被引:120
作者
Abell, Robin G. [1 ]
Davies, Peter E. J. [2 ]
Phelan, David [3 ]
Goemann, Karsten [4 ]
McPherson, Zachary E. [2 ]
Vote, Brendan J. [1 ]
机构
[1] Tasmanian Eye Inst, Launceston, Tas, Australia
[2] Newcastle Eye Hosp Res Fdn, Newcastle, NSW, Australia
[3] Univ Newcastle, Electron Microscopy Unit, Callaghan, NSW 2308, Australia
[4] Univ Tasmania, Cent Sci Lab, Hobart, Tas, Australia
关键词
CONTINUOUS CURVILINEAR CAPSULORHEXIS; INTRAOPERATIVE COMPLICATIONS; MECHANICAL-PROPERTIES; ELASTIC PROPERTIES; PHACOEMULSIFICATION; PARAMETERS; OUTCOMES; RISK;
D O I
10.1016/j.ophtha.2013.08.013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To compare the incidence of anterior capsular tears after femtosecond laser-assisted cataract surgery (FLACS) versus phacoemulsification cataract surgery (PCS) and to assess the ultrastructural features of anterior capsulotomy specimens (FLACS and PCS) using electron microscopy. Design: Prospective, multicenter, comparative cohort case series. Participants: Consecutive patients undergoing FLACS or PCS. Methods: A prospective cohort study of all patients (n = 1626) undergoing FLACS or PCS by 2 surgeons from centers A and B was undertaken to compare the incidence of anterior capsule tears. Anterior lens capsules were collected by 4 surgeons from centers A, B, C, and D using 3 different commercially available femtosecond platforms, each with latest version upgrades. Lens capsule tissue was prepared for scanning electron microscopy (SEM) using a total of 10 samples for patients undergoing PCS, and 40 samples for patients undergoing FLACS. Main Outcome Measures: Incidence of anterior capsule tear and comparative ultrastructural features of capsular samples from both PCS and FLACS cases. Results: There was a significantly increased rate of anterior capsule tears in the FLACS group (15/804 [1.87%]) when compared with the PCS group (1/822 [0.12%]; P = 0.0002, Fisher exact test). In 7 cases, the anterior capsule tear extended to the posterior capsule. Because all cases had occurred in complete capsulotomy, the integrity of the anterior capsule was questioned in the FLACS group. Subsequent SEM sampling showed irregularity at the capsule margin, as well as multiple apparently misplaced laser pits in normal parts of the tissue. Aberrant pits were approximately 2 to 4 mu m apart and occurred at a range of 10 to 100 mu m radially from the capsule edge. Conclusions: Laser anterior capsulotomy integrity seems to be compromised by postage-stamp perforations and additional aberrant pulses, possibly because of fixational eye movements. This can lead to an increased rate of anterior capsule tears, and extra care should be taken during surgery after femtosecond laser pretreatment has been performed. A learning curve may account for some of the increased complication rate with FLACS. However, the SEM features raise safety concerns for capsular integrity after FLACS and warrant further investigation. (C) 2014 by the American Academy of Ophthalmology.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 44 条
[11]   Femtosecond laser capsulotomy [J].
Friedman, Neil J. ;
Palanker, Daniel V. ;
Schuele, Georg ;
Andersen, Dan ;
Marcellino, George ;
Seibel, Barry S. ;
Battle, Juan ;
Feliz, Rafael ;
Talamo, Jonathan H. ;
Blumenkranz, Mark S. ;
Culbertson, William W. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (07) :1189-1198
[12]   DEVELOPMENT, ADVANTAGES, AND METHODS OF THE CONTINUOUS CIRCULAR CAPSULORHEXIS TECHNIQUE [J].
GIMBEL, HV ;
NEUHANN, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (01) :31-37
[13]   Analysis of the capsule edge after Fugo plasma blade capsulotomy, continuous curvilinear capsulorhexis, and can-opener capsulotomy [J].
Izak, AM ;
Werner, L ;
Pandey, SK ;
Apple, DJ ;
Izak, MGJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (12) :2606-2611
[14]   Comparison of capsulorhexis resistance to tearing with and without trypan blue dye using a mechanized tensile strength model [J].
Jaber, Ryan ;
Werner, Liliana ;
Fuller, Stan ;
Kavoussi, Shaheen C. ;
McIntyre, Steele ;
Burrow, Michael ;
Mamalis, Nick .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (03) :507-512
[15]   Intraocular pressure during femtosecond laser pretreatment of cataract [J].
Kerr, Nathan M. ;
Abell, Robin G. ;
Vote, Brendan J. ;
Toh, Tze 'Yo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (03) :339-342
[16]   Mechanical properties of the human lens capsule [J].
Krag, S ;
Andreassen, TT .
PROGRESS IN RETINAL AND EYE RESEARCH, 2003, 22 (06) :749-767
[17]   Diathermic capsulotomy versus capsulorhexis: A biomechanical study [J].
Krag, S ;
Thim, K ;
Corydon, L .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (01) :86-90
[18]   Intraocular Lens Tilt and Decentration Measured By Scheimpflug Camera Following Manual or Femtosecond Laser-created Continuous Circular Capsulotomy [J].
Kranitz, Kinga ;
Mihaltz, Kata ;
Sandor, Gabor L. ;
Takacs, Agnes ;
Knorz, Michael C. ;
Nagy, Zoltan Z. .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (04) :259-263
[19]   Femtosecond Laser Capsulotomy and Manual Continuous Curvilinear Capsulorrhexis Parameters and Their Effects on Intraocular Lens Centration [J].
Kranitz, Kinga ;
Takacs, Agnes ;
Mihaltz, Kata ;
Kovacs, Illes ;
Knorz, Michael C. ;
Nagy, Zoltan Z. .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (08) :558-563
[20]   Outcomes of Femtosecond Laser Cataract Surgery With a Diffractive Multifocal Intraocular Lens [J].
Lawless, Michael ;
Bali, Shveta Jindal ;
Hodge, Chris ;
Roberts, Timothy V. ;
Chan, Colin ;
Sutton, Gerard .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (12) :859-864