Complications after volar locking plate fixation of distal radius fractures

被引:77
作者
Johnson, N. A. [1 ]
Cutler, L. [1 ]
Dias, J. J. [1 ]
Ullah, A. S. [1 ]
Wildin, C. J. [1 ]
Bhowal, B. [1 ]
机构
[1] Leicester Royal Infirm, Leicester LE1 5WW, Leics, England
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2014年 / 45卷 / 03期
关键词
Distal radius; Volar locking plates; Internal fixation; Complications; DORSALLY DISPLACED FRACTURES; POLLICIS LONGUS TENDON; INTERNAL-FIXATION; UNSTABLE FRACTURES; OPEN REDUCTION; MULTICENTER; AVOIDANCE; PLACEMENT; RUPTURES; SYSTEM;
D O I
10.1016/j.injury.2013.10.003
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Volar locking plates are an increasingly popular treatment for distal radius fractures. We reviewed complications observed after volar locking plate fixation in a busy teaching hospital. The purpose of the study was to assess whether complication rates after volar locking plate use in general, routine trauma practice were higher than published literature from expert users. A retrospective review was carried out of patients treated with a volar locking plate between January 2009 and December 2010. The series included 206 procedures in 204 patients (77 males and 127 females) with mean age of 55 years (range 16-94). Surgery was performed by 18 different consultant surgeons and 11 registrars. A total of 22 complications were observed in 20 patients with an overall complication rate of 9.7%. Seven (3.4%) patients developed tendon problems including four (1.9%) tendon ruptures. Four (1.9%) patients required re-operation for metalwork problems; four patients developed complex regional pain syndrome (CRPS). Three fracture reduction problems were noted. A total of 16 further operations were carried out for complications. The overall complication rate was low even when surgery was done by many surgeons, suggesting that this is a safe and reproducible technique. This study provides information which can be used to counsel patients about risks, including those of tendon and metalwork problems. This allows patients to make an informed decision. Surgeons must have specific strategies to avoid these complications and remain vigilant so that these can be identified and managed early. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:528 / 533
页数:6
相关论文
共 28 条
[1]   Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures [J].
Al-Rashid, M. ;
Theivendran, K. ;
Craigen, M. A. C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (12) :1610-1612
[2]   Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[3]   Fracture risk in the US Medicare population [J].
Barrett, JA ;
Baron, JA ;
Karagas, MR ;
Beach, ML .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1999, 52 (03) :243-249
[4]   Rupture of flexor pollicis longus tendon - A complication of volar plating of the distal radius [J].
Bell, JSP ;
Wollstein, R ;
Citron, ND .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :225-226
[5]   Peripheral nerve compression neuropathy after fractures of the distal radius [J].
Bienek, T. ;
Kusz, D. ;
Cielinski, L. .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2006, 31B (03) :256-260
[6]   Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal radius plate [J].
Campbell, DA .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (06) :528-534
[7]   Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures [J].
Carter, PR ;
Frederick, HA ;
Laseter, GF .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (02) :300-307
[8]   Treatment of unstable distal radial fractures with the volar locking plating system [J].
Chung, Kevin C. ;
Watt, Andrew J. ;
Kotsis, Sandra V. ;
Margaliot, Zvi ;
Haase, Steven C. ;
Kim, Myra .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (12) :2687-2694
[9]  
Cooper EO, 2007, AM J ORTHOP, V36, P46
[10]   Osteosynthesis of distal radial fractures with a volar locking screw plate system [J].
Drobetz, H ;
Kutscha-Lissberg, E .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) :1-6