AN IN VITRO COMPARISON OF THE ACCURACY OF IMPLANT IMPRESSIONS WITH CODED HEALING ABUTMENTS AND DIFFERENT IMPLANT ANGULATIONS

被引:32
作者
Al-Abdullah, Khaled [1 ]
Zandparsa, Roya [2 ]
Finkelman, Matthew [3 ]
Hirayama, Hiroshi [4 ]
机构
[1] Tufts Univ, Sch Dent Med, Postgrad Prosthodont Div, Boston, MA 02111 USA
[2] Tufts Univ, Sch Dent Med, Dept Prosthodont & Operat Dent, Prosthodont Div, Boston, MA 02111 USA
[3] Tufts Univ, Sch Dent Med, Dept Publ Hlth & Community Serv, Boston, MA 02111 USA
[4] Tufts Univ, Sch Dent Med, Boston, MA 02111 USA
关键词
DENTAL IMPLANTS; DIMENSIONAL ACCURACY; PROSTHESES; FIT; BONE;
D O I
10.1016/S0022-3913(13)60346-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Fabricating implant definitive casts with CAD/CAM technology (Robocasts) from coded healing abutment impressions represents a simpler and innovative alternative to conventional implant impression techniques. However, information about the accuracy of the impressions and the resultant definitive casts is limited. Purpose. The purpose of the study was to evaluate the accuracy of the Robocasts and compare them to those definitive casts fabricated with conventional implant impression techniques (open tray with splinted impression copings technique). Material and methods. A reference epoxy resin cast was fabricated and shaped to simulate a dental arch. Two regular platform implant replicas (Biomet 3i Certain, 4.1 mm diameter and 15 mm length) with internal connections were placed 10 mm apart with a 10-degree convergence for one side of the reference resin cast and a 30-degree convergence for the other. Coded healing abutments (Encode) were placed at 3 different heights above the level of the soft tissue replication material (approximately 1, 2, and 4 mm) and served as test groups (El, E2, and E4), and open trays with splinted impression copings (OTSC) served as a control group. The control group was compared to the impressions of the coded healing abutments by using a standardized measurement protocol. Impressions were made for each group (n=18) and poured with vacuum mixed (100 g powder/20 mL water) Type IV dental stone. The vertical discrepancy (Z axis) between 2 prefabricated passively fitting titanium reference frameworks and the platforms of the implant replicas was measured with an optical comparator applying the 1 screw test. Data were analyzed with Kruskal-Wallis and post-hoc Mann-Whitney U tests, as well as the Wilcoxon signed-rank tests. The Bonferroni correction was used to account for multiple comparisons. The significance level (alpha) used in a given set of tests was equal to .05 divided by the number of tests performed in that set. Results. The median vertical discrepancy of each coded healing abutment impression group was higher than the corresponding median of the control group (OTSC) for every combination of angulation and position. Kruskal-Wallis tests indicated a statistically significant difference (P<.001) between groups for each angulation/position combination. All post hoc Mann-Whitney U tests indicated statistically significant differences (all P <=.002) between OTSC and the other groups. Differences between the angulations and positions were not statistically significant when accounting for multiple comparisons. Conclusions. The implant definitive casts fabricated from the coded healing abutment impressions were found to be less accurate than those fabricated from the open tray with splinted impression copings technique for restoring 2 paired (10 or 30 degrees) convergent internal connection implants with nonengaging screw-retained splinted 2-unit implant restorations. Accuracy of fit was not influenced by the implant angulation or position for either impression technique or by the Encode healing abutment height for the Encode impression technique. (J Prosthet Dent 2013;110:90-100)
引用
收藏
页码:90 / 100
页数:11
相关论文
共 43 条
[1]   ANALYSIS OF THREE-DIMENSIONAL DISTORTION OF TWO IMPRESSION MATERIALS IN THE TRANSFER OF DENTAL IMPLANTS [J].
Aguilar, Maria L. ;
Elias, Augusto ;
Vizcarrondo, Carlos E. Toro ;
Psoter, Walter J. .
JOURNAL OF PROSTHETIC DENTISTRY, 2010, 103 (04) :202-209
[2]  
Assif D, 1996, Int J Oral Maxillofac Implants, V11, P216
[3]  
Assif D, 1992, Int J Periodontics Restorative Dent, V12, P112
[4]  
Assuncao Wirley Goncalves, 2004, Implant Dent, V13, P358
[5]   POLYMERIZATION OF METHYL ALPHA-CYANOACRYLATE .2. CONDITIONS FOR RADICAL POLYMERIZATION [J].
BEVINGTON, JC ;
JEMMETT, JAL ;
ONYON, PF .
EUROPEAN POLYMER JOURNAL, 1976, 12 (04) :255-257
[6]   OSSEOINTEGRATION AND ITS EXPERIMENTAL BACKGROUND [J].
BRANEMARK, PI .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (03) :399-410
[7]   MODIFIED BOXING TECHNIQUE FOR MANDIBULAR IMPRESSIONS [J].
BRONER, AS ;
SONI, A ;
GOLDSTEIN, GR .
JOURNAL OF PROSTHETIC DENTISTRY, 1982, 47 (04) :454-456
[8]   A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system [J].
Burawi, G ;
Houston, F ;
Byrne, D ;
Claffey, N .
JOURNAL OF PROSTHETIC DENTISTRY, 1997, 77 (01) :68-75
[9]   TIGHTENING CHARACTERISTICS FOR SCREWED JOINTS IN OSSEOINTEGRATED DENTAL IMPLANTS [J].
BURGUETE, RL ;
JOHNS, RB ;
KING, T ;
PATTERSON, EA .
JOURNAL OF PROSTHETIC DENTISTRY, 1994, 71 (06) :592-599
[10]   Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays [J].
Burns, J ;
Palmer, R ;
Howe, L ;
Wilson, R .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (03) :250-255