Automatic ROI Placement in the Upper Trapezius Muscle in B-mode Ultrasound Images

被引:3
作者
Behr, Michael [1 ]
McNabb, Evan [2 ]
Noseworthy, Michael [3 ,4 ,5 ,6 ]
Sidkar, Siddhartha [7 ]
Kumbhare, Dinesh [1 ,3 ,4 ,8 ,9 ]
机构
[1] Univ Toronto, Dept Med, Div Phys Med & Rehabil, Toronto, ON, Canada
[2] Sunnybrook Res Inst, Phys Sci, Toronto, ON, Canada
[3] McMaster Univ, McMaster Sch Biomed Engn, Hamilton, ON, Canada
[4] St Josephs Healthcare, Imaging Res Ctr, Hamilton, ON, Canada
[5] McMaster Univ, Dept Radiol, Hamilton, ON, Canada
[6] McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON, Canada
[7] George Mason Univ, Dept Engn, Fairfax, VA 22030 USA
[8] Univ Toronto, Toronto, ON, Canada
[9] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON, Canada
关键词
B-mode; ultrasound; automatic; muscle; ROI; MYOFASCIAL TRIGGER POINTS; LOCALIZED RADON-TRANSFORM; FIBER ORIENTATION; ULTRASONOGRAPHY; ENHANCEMENT; THICKNESS;
D O I
10.1177/0161734619839980
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Research involving B-mode ultrasound imaging often requires user defined regions of interest (ROIs) for analysis, traditionally drawn/selected by a trained operator. This manual process is incredibly time consuming and subjective. Here, we propose a fast and simple method of detecting the average location of aponeurosis layers in ultrasound images of the upper trapezius to place a rectangular ROI for quantitative image analysis. A total of 56 B-mode ultrasound images were analyzed, where rectangular ROIs were manually placed in the skeletal muscle by two trained operators. Interoperator agreement was determined between the ROI border locations using intercorrelation coefficient (ICC). Next, our automatic algorithm was applied (image thresholding, binary masking, and pixel intensity peak detection), estimating the mean position of both aponeurosis layers for rectangular ROI placement. The automatic estimation method was compared with the manual (visual) method by various statistics (t test, linear correlation, Bland-Altman plot). The performance was also evaluated under additive noise conditions (Speckle). Finally, agreement of the overlapping ROI area between the manual and automatic methods was also computed. Performance of the automatic method compared with manual placement was excellent for both the superficial and deep ROI borders, performing consistently even with additive noise (error <0.674 +/- 1.69 mm). Manual measurements indicated excellent consensus (ICC = 0.902) between operators. The overlapping area between the manual and automatic measurements demonstrated good agreement (90.65 +/- 11.3%). With constraints, our method is robust even under large levels of noise addition making the automatic algorithm an acceptable replacement for manual ROI placement in the upper trapezius.
引用
收藏
页码:231 / 246
页数:16
相关论文
共 26 条
[1]   Objective Sonographic Measures for Characterizing Myofascial Trigger Points Associated With Cervical Pain [J].
Ballyns, Jeffrey J. ;
Shah, Jay P. ;
Hammond, Jennifer ;
Gebreab, Tadesse ;
Gerber, Lynn H. ;
Sikdar, Siddhartha .
JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (10) :1331-1340
[2]  
Behr M, 2019, J ULTRAS MED, V9999, P1
[3]  
COPELAND AC, 1994, P SOC PHOTO-OPT INS, V2234, P26, DOI 10.1117/12.181042
[4]   Deep Residual Networks for Quantification of Muscle Fiber Orientation and Curvature from Ultrasound Images [J].
Cunningham, Ryan ;
Harding, Peter ;
Loram, Ian .
MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2017), 2017, 723 :63-73
[5]   Real-Time Ultrasound Segmentation, Analysis and Visualisation of Deep Cervical Muscle Structure [J].
Cunningham, Ryan J. ;
Harding, Peter J. ;
Loram, Ian D. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (02) :653-665
[6]  
Darby J, 2011, J APPL PHYSIOL, V112, P313
[7]   Estimating Skeletal Muscle Fascicle Curvature From B-Mode Ultrasound Image Sequences [J].
Darby, John ;
Li, Baihua ;
Costen, Nicholas ;
Loram, Ian ;
Hodson-Tole, Emma .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (07) :1935-1945
[8]   USE OF HOUGH TRANSFORMATION TO DETECT LINES AND CURVES IN PICTURES [J].
DUDA, RO ;
HART, PE .
COMMUNICATIONS OF THE ACM, 1972, 15 (01) :11-&
[9]  
Godin G., 2011, HLTH FITNESS J CANAD, V4, P18, DOI [DOI 10.14288/HFJC.V4I1.82, 10.14288/hfjc.v4i1.82]
[10]   Automatic thickness estimation for skeletal muscle in ultrasonography: evaluation of two enhancement methods [J].
Han, Pan ;
Chen, Ye ;
Ao, Lijuan ;
Xie, Gaosheng ;
Li, Huihui ;
Wang, Lei ;
Zhou, Yongjin .
BIOMEDICAL ENGINEERING ONLINE, 2013, 12