The effect of irradiance mismatch on a semi-dense array of triple-junction concentrator cells

被引:21
作者
Cooper, Thomas [1 ]
Pravettoni, Mauro [2 ]
Cadruvi, Monica [1 ]
Ambrosetti, Gianluca [3 ]
Steinfeld, Aldo [1 ,4 ]
机构
[1] ETH, Dept Mech & Proc Engn, CH-8092 Zurich, Switzerland
[2] Univ Appl Sci & Arts Southern Switzerland, Inst Appl Sustainabil Built Environm, CH-6952 Canobbio, Switzerland
[3] Airlight Energy Mfg SA, CH-6710 Biasca, Switzerland
[4] Paul Scherrer Inst, Solar Technol Lab, CH-5232 Villigen, Switzerland
关键词
Mismatch loss; Non-uniformity; Apodizing filter; Equivalent circuit; Serial array; SIMPLEX-METHOD; LOSSES; FLUX;
D O I
10.1016/j.solmat.2013.04.027
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A method to determine the effect of cell-to-cell non-uniformity on CPV module performance is applied to a high-concentration photovoltaic system, comprising a linear semi-dense array of 5 series-connected 1 cm(2) triple-junction concentrator cells (lattice-matched GaInP/GaAs/Ge). Characteristic irradiance distributions were obtained by Monte Carlo ray-tracing of the concentrator optical system. Spatial apodizing filters were then produced such that, when illuminated with a spatially uniform radiation source, the desired irradiance distribution is obtained behind the filter. An equivalent circuit model of the array was developed and fitted against reference uniform irradiance measurements at concentrations ranging from 10x to 1678x. The fitted model was then validated vis-a-vis measurements under non-uniform irradiance imposed by the filters at concentrations from 99x to 494x. Both experimental and simulated results show a characteristic stepped I-V behavior associated with irradiance mismatch in series-connected arrays. Under the worst-case conditions of irradiance mismatch over the array, the efficiency drops to 28.5% as compared to 39% for the case of perfect uniformity. Due to the translational symmetry of the primary concentrator, a redesign of the module with parallel cell interconnects enables to mitigate the effects of irradiance mismatch. The methods provide an experimentally verifiable approach to determine the effect of irradiance mismatch on concentrator solar cell arrays without the need for prototyping of the concentrator optics. They may further be applied to determine the underlying characteristics and properties of cells and arrays subjected to nonuniform irradiation. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:238 / 251
页数:14
相关论文
共 45 条
[1]   Experimental study of mismatch and shading effects in the I-V characteristic of a photovoltaic module [J].
Alonso-García, MC ;
Ruiz, JM ;
Chenlo, F .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2006, 90 (03) :329-340
[2]  
[Anonymous], P ASME 4 INT C EN SU
[3]  
[Anonymous], NEXT GENERATION PHOT
[4]  
Azur Space Solar Power GmbH, 2012, 00030550003 HNR AZ S
[5]   A 9-m-Aperture Solar Parabolic Trough Concentrator Based on a Multilayer Polymer Mirror Membrane Mounted on a Concrete Structure [J].
Bader, Roman ;
Pedretti, Andrea ;
Steinfeld, Aldo .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (03)
[6]  
Ben Or A., 2012, PROGR PHOTOVOLTAICS
[7]  
Benítez P, 1999, APPL PHYS LETT, V74, P2543, DOI 10.1063/1.123892
[8]   Localized irradiation effects on tunnel diode transitions in multi-junction concentrator solar cells [J].
Braun, Avi ;
Hirsch, Baruch ;
Katz, Eugene A. ;
Gordon, Jeffrey M. ;
Guter, Wolfgang ;
Bett, Andreas W. .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2009, 93 (09) :1692-1695
[9]   POWER LOSS IN PHOTO-VOLTAIC ARRAYS DUE TO MISMATCH IN CELL CHARACTERISTICS [J].
BUCCIARELLI, LL .
SOLAR ENERGY, 1979, 23 (04) :277-288
[10]   EFFECTS OF MISMATCH LOSSES IN PHOTOVOLTAIC ARRAYS [J].
CHAMBERLIN, CE ;
LEHMAN, P ;
ZOELLICK, J ;
PAULETTO, G .
SOLAR ENERGY, 1995, 54 (03) :165-171