SERS-Based Pump-Free Microfluidic Chip for Highly Sensitive Immunoassay of Prostate-Specific Antigen Biomarkers

被引:96
|
作者
Gao, Rongke [1 ]
Lv, Zeyuan [1 ]
Mao, Yuanshuo [1 ]
Yu, Liandong [1 ]
Bi, Xiaobai [1 ]
Xu, Shenghao [3 ]
Cui, Jiewu [2 ]
Wu, Yucheng [2 ]
机构
[1] Hefei Univ Technol, Sch Instrument Sci & Optoelect Engn, Hefei 230009, Anhui, Peoples R China
[2] Hefei Univ Technol, Sch Mat Sci & Engn, Hefei 230009, Anhui, Peoples R China
[3] Qingdao Univ Sci & Technol, Shandong Key Lab Biochem Anal, Coll Chem & Mol Engn, Qingdao 266042, Shandong, Peoples R China
来源
ACS SENSORS | 2019年 / 4卷 / 04期
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
prostate cancer; pump free microfluidics; SERS; immunoassay; prostate-specific antigen; CANCER; SPECTROSCOPY; PLATFORM; MARKER; SYSTEM; PSA;
D O I
10.1021/acssensors.9b00039
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Highly sensitive analysis of cancer biomarkers demonstrates an important impact in early diagnosis and therapies of cancer. A novel surface-enhanced Raman scattering (SERS) based immunoassay using microfluidic technique was reported for rapid analysis of prostate-specific antigen (PSA) biomarker. It is a useful screening test to discriminate prostate cancer and other diseases related to prostate. A "sandwich" immunoassay based on SERS nanotags, PSA biomarkers, and magnetic beads was applied on a pump-free microfluidic sensor. Magnetic immunocomplexes are isolated and trapped at the detection chamber by a permanent magnet integrated into the chip. The PBS buffer washed magnetic immunocomplexes and brought the free gold nanoparticles to the downsteam channel for waste. Our results show a good linear response in the range from 0.01 to 100 ng mL(-1). The limit of detection of the PSA level is estimated to be below 0.01 ng mL(-1) using this chip. This detection level of PSA biomarker in human serum can be accomplished in 5 min without manual incubation and a heavy syringe pump. To the best of our knowledge, this is the first SERS-based immunoassay which applied a pump-free microfluidic chip as a detection platform. We believe that the proposed method reveals a valuable potential tool for the diagnosis of prostate cancer.
引用
收藏
页码:938 / 943
页数:11
相关论文
共 50 条
  • [1] Simultaneous SERS-based immunoassay of dual cardiac markers on pump-free hybrid microfluidic chip
    Gao, Rongke
    Chen, Feng
    Yang, Dongdong
    Zheng, Lihua
    Jing, Tongmei
    Jia, Huakun
    Chen, Xiaozhe
    Lu, Yang
    Xu, Shenghao
    Zhang, Dongzhi
    Yu, Liandong
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 369
  • [2] Digital droplet immunoassay based on a microfluidic chip with magnetic beads for the detection of prostate-specific antigen
    Zeng, Zhaokui
    Tian, Jingjing
    Ren, Zixuan
    Yang, Ying
    Gong, Qian
    Sun, Ruowei
    Zhang, Xun
    Liu, Wenfang
    Chen, Chuanpin
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (24)
  • [3] Pump-Free Glass-Based Capillary Microfluidic Immuno-Assay Chip for Electrochemical Detection of Prostate-Specific Antigen
    Lee, Myeong Jun
    Yeom, Jina
    Choi, Jin-Ha
    Shin, Jeong Hyeop
    Kim, Tae Hwan
    Jeon, Ju-Won
    Na, Jeong-Geol
    Shin, Kwanwoo
    Oh, Byung-Keun
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2020, 20 (08) : 4629 - 4633
  • [4] Ultrasensitive detection of prostate-specific antigen using a SERS-based magnetic immunosensor
    Zhao, Junqi
    Guo, Shuang
    Liu, Yawen
    Park, Eungyeong
    Jin, Sila
    Park, Yeonju
    Han, Xiaoxia
    Zhao, Bing
    Jung, Young Mee
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 413
  • [5] Bioanalytical Application of SERS Immunoassay for Detection of Prostate-Specific Antigen
    Yoon, Kyung Jin
    Seo, Hyeong Kuyn
    Hwang, Hoon
    Pyo, Dongjin
    Eom, In-Yong
    Hahn, Jong Hoon
    Jung, Young Mee
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2010, 31 (05): : 1215 - 1218
  • [6] Dual monoclonal antibody immunoassay for free prostate-specific antigen
    Wang, TJ
    Hill, TM
    Sokoloff, RL
    Frankenne, F
    Rittenhouse, HG
    Wolfert, RL
    PROSTATE, 1996, 28 (01) : 10 - 16
  • [7] Magnetic-particle-based, ultrasensitive chemiluminescence enzyme immunoassay for free prostate-specific antigen
    Liu, Ruping
    Wang, Cheng
    Jiang, Quan
    Zhang, Wei
    Yue, Zhao
    Liu, Guohua
    ANALYTICA CHIMICA ACTA, 2013, 801 : 91 - 96
  • [8] Ultrasensitive immunoassay for free prostate-specific antigen based on ferrocenecarboxylate enhanced cathodic electrochemiluminescence of peroxydisulfate
    Zhang, Fei
    Mao, Li
    Zhu, Meiqiong
    MICROCHIMICA ACTA, 2014, 181 (11-12) : 1285 - 1291
  • [9] Highly sensitive immunoassay of free prostate-specific antigen in serum using europium(III) nanoparticle label technology
    Soukka, T
    Antonen, K
    Härmä, H
    Pelkkikangas, AM
    Huhtinen, P
    Lövgren, T
    CLINICA CHIMICA ACTA, 2003, 328 (1-2) : 45 - 58
  • [10] A novel SERS-based magnetic aptasensor for prostate specific antigen assay with high sensitivity
    Yang, Kang
    Hu, Yongjun
    Dong, Ning
    Zhu, Guichi
    Zhu, Tingfeng
    Jiang, Ningjing
    BIOSENSORS & BIOELECTRONICS, 2017, 94 : 286 - 291