Ultrashort echo time (UTE) MRI for the assessment of caries lesions

被引:54
|
作者
Bracher, A-K [1 ]
Hofmann, C. [1 ,2 ]
Bornstedt, A. [1 ]
Hell, E. [3 ]
Janke, F. [2 ]
Ulrici, J. [3 ]
Haller, B. [2 ]
Geibel, M-A [4 ]
Rasche, V. [1 ]
机构
[1] Univ Hosp Ulm, Dept Internal Med 2, D-89081 Ulm, Germany
[2] Univ Hosp Ulm, Dept Operat Dent & Periodontol, D-89081 Ulm, Germany
[3] Sirona Dent Syst GmbH, Bensheim, Germany
[4] Univ Hosp Ulm, Dept Oral & Maxillofacial Surg, D-89081 Ulm, Germany
关键词
dental magnetic resonance imaging; ultrashort echo time; early detection of caries lesions; TEMPOROMANDIBULAR-JOINT; DISC DISPLACEMENT; RESONANCE; NMR; TOMOGRAPHY; ARTIFACTS; CAVITY; BONE;
D O I
10.1259/dmfr.20120321
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: Direct in vivo MRI of dental hard tissues by applying ultrashort echo time (UTE) MRI techniques has recently been reported. The objective of the presented study is to clinically evaluate the applicability of UTE MRI for the identification of caries lesions. Methods: 40 randomly selected patients (mean age 41 +/- 15 years) were enrolled in this study. 39 patients underwent a conventional clinical assessment, dental bitewing X-ray and a dental MRI investigation comprising a conventional turbo-spin echo (TSE) and a dedicated UTE scan. One patient had to be excluded owing to claustrophobia. In four patients, the clinical treatment of the lesions was documented by intraoral pictures, and the resulting volume of the cavity after excavation was documented by dental imprints and compared with the MRI findings. Results: In total, 161 lesions were identified. 157 (97%) were visible in the UTE images, 27 (17%) in the conventional TSE images and 137 (85%) in the X-ray images. In total, 14 teeth could not be analysed by MR owing to artefacts caused by dental fillings. All lesions appear significantly larger in the UTE images as compared with the X-ray and TSE images. In situ measurements confirm the accuracy of the lesion dimensions as observed in the UTE images. Conclusion: The presented data provide evidence that UTE MR imaging can be applied for the identification of caries lesions. Although the current data suggest an even higher sensitivity of UTE MRI, some limitations must be expected from dental fillings.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Water proton density in human cortical bone obtained from ultrashort echo time (UTE) MRI predicts bone microstructural properties
    Jerban, Saeed
    Ma, Yajun
    Jang, Hyungseok
    Namiranian, Behnam
    Le, Nicole
    Shirazian, Hoda
    Murphy, Mark E.
    Du, Jiang
    Chang, Eric Y.
    MAGNETIC RESONANCE IMAGING, 2020, 67 : 85 - 89
  • [32] Contrast-enhanced MRI of the menisci of the knee using ultrashort echo time (UTE) pulse sequences: imaging of the red and white zones
    Gatehouse, PD
    He, T
    Puri, BK
    Thomas, RD
    Resnick, D
    Bydder, GM
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (920): : 641 - 647
  • [33] Measuring Acute and Chronic Fibrosis Over the Course of Radiation Therapy in Gynecological Cancer Patients Using Ultrashort Echo Time (UTE) MRI
    Sheikh, K.
    Lee, J.
    Seethamraju, R.
    Benkert, T.
    Bhat, H.
    Daniel, B.
    Song, D.
    Viswanathan, A.
    Schmidt, E.
    MEDICAL PHYSICS, 2022, 49 (06) : E595 - E596
  • [34] Ultrashort echo time (UTE) imaging using gradient pre-equalization and compressed sensing
    Fabich, Hilary T.
    Benning, Martin
    Sederman, Andrew J.
    Holland, Daniel J.
    JOURNAL OF MAGNETIC RESONANCE, 2014, 245 : 116 - 124
  • [35] Assessment of iron nanoparticle distribution in mouse models using ultrashort-echo-time MRI
    Boss, Andreas
    Heeb, Laura
    Vats, Divya
    Starsich, Fabian H. L.
    Balfourier, Alice
    Herrmann, Inge K.
    Gupta, Anurag
    NMR IN BIOMEDICINE, 2022, 35 (06)
  • [36] COMPARISON OF SHORT ECHO TIME MRI, UTE MRI, AND CHEST CT IN PEDIATRIC CF PATIENTS
    Cooper, M.
    Lin, C.
    Thompson, M.
    Netter, L.
    Ren, C. L.
    PEDIATRIC PULMONOLOGY, 2017, 52 : S384 - S385
  • [37] Expanding the Clinical Application of Lung MRI: With or without Ultrashort Echo Time or Zero Echo Time?
    Dournes, Gael
    Benlala, Ilyes
    Laurent, Francois
    RADIOLOGY, 2021, 301 (02) : E412 - E412
  • [38] MR-Based Attenuation Correction for PET using an Ultrashort Echo Time (UTE) sequence
    Keereman, Vincent
    Vandenberghe, Stefaan
    De Deene, Yves
    Luypaert, Robert
    Broux, Tom
    Lemahieu, Ignace
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3929 - +
  • [39] Whole-Brain Myelin Imaging Using 3D Double-Echo Sliding Inversion Recovery Ultrashort Echo Time (DESIRE UTE) MRI
    Ma, Ya-Jun
    Searleman, Adam C.
    Jang, Hyungseok
    Wong, Jonathan
    Chang, Eric Y.
    Corey-Bloom, Jody
    Bydder, Graeme M.
    Du, Jiang
    RADIOLOGY, 2020, 294 (02) : 362 - 374
  • [40] Determination of blood circulation times of superparamagnetic iron oxide nanoparticles by T2*relaxometry using ultrashort echo time (UTE) MRI
    Scharlach, Constantin
    Warmuth, Carsten
    Schellenberger, Eyk
    MAGNETIC RESONANCE IMAGING, 2015, 33 (09) : 1173 - 1177