Characterization of drug-release kinetics in trabecular bone from titania nanotube implants

被引:45
作者
Aw, Moom Sinn [1 ]
Khalid, Kamarul A. [2 ,3 ]
Gulati, Karan [1 ]
Atkins, Gerald J. [2 ]
Pivonka, Peter [4 ]
Findlay, David M. [2 ]
Losic, Dusan [1 ]
机构
[1] Univ Adelaide, Sch Chem Engn, Adelaide, SA 5005, Australia
[2] Univ Adelaide, Discipline Orthopaed & Trauma, Adelaide, SA 5005, Australia
[3] Int Islamic Univ Malaysia, Fac Med, Dept Orthopaed Traumatol & Rehabil, Kuantan, Pahang, Malaysia
[4] Univ Western Australia, Sch Comp Sci & Software Engn, Engn Computat Biol Grp, Perth, WA 6009, Australia
来源
INTERNATIONAL JOURNAL OF NANOMEDICINE | 2012年 / 7卷
基金
澳大利亚研究理事会; 英国医学研究理事会;
关键词
local drug delivery; Zetos bone bioreactor; drug-releasing implant; drug diffusion; DELIVERY SYSTEMS; TI WIRES; ARRAYS; INFECTION; COATINGS; FUTURE; CELLS; ZETOS;
D O I
10.2147/IJN.S33655
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Purpose: The aim of this study was to investigate the application of the three-dimensional bone bioreactor for studying drug-release kinetics and distribution of drugs in the ex vivo cancellous bone environment, and to demonstrate the application of nanoengineered titanium (Ti) wires generated with titania nanotube (TNT) arrays as drug-releasing implants for local drug delivery Methods: Nanoengineered Ti wires covered with a layer of TNT arrays implanted in bone were used as a drug-releasing implant. Viable bovine trabecular bone was used as the ex vivo bone substrate embedded with the implants and placed in the bone reactor. A hydrophilic fluorescent dye (rhodamine B) was used as the model drug, loaded inside the TNT-Ti implants, to monitor drug release and transport in trabecular bone. The distribution of released model drug in the bone was monitored throughout the bone structure, and concentration profiles at different vertical (0-5 mm) and horizontal (0-10 mm) distances from the implant surface were obtained at a range of release times from 1 hour to 5 days. Results: Scanning electron microscopy confirmed that well-ordered, vertically aligned nanotube arrays were formed on the surface of prepared TNT-Ti wires. Thermogravimetric analysis proved loading of the model drug and fluorescence spectroscopy was used to show drug-release characteristics in-vitro. The drug release from implants inserted into bone ex vivo showed a consistent gradual release of model drug from the TNT-Ti implants, with a characteristic three-dimensional distribution into the surrounding bone, over a period of 5 days. The parameters including the flow rate of bone culture medium, differences in trabecular microarchitecture between bone samples, and mechanical loading were found to have the most significant influence on drug distribution in the bone. Conclusion: These results demonstrate the utility of the Zetos (TM) T system for ex vivo drug-release studies in bone, which can be applied to optimize the delivery of specific therapies and to assist in the design of new drug delivery systems. This method has the potential to provide new knowledge to understand drug distribution in the bone environment and to considerably improve existing technologies for local administration in bone, including solving some critical problems in bone therapy and orthopedic implants.
引用
收藏
页码:4883 / 4892
页数:10
相关论文
共 40 条
  • [1] Anodized 20 nm diameter nanotubular titanium for improved bladder stent applications
    Alpaslan, Ece
    Ercan, Batur
    Webster, Thomas J.
    [J]. INTERNATIONAL JOURNAL OF NANOMEDICINE, 2011, 6 : 219 - 225
  • [2] Ordered Mesoporous Microspheres for Bone Grafting and Drug Delivery
    Arcos, D.
    Lopez-Noriega, A.
    Ruiz-Hernandez, E.
    Terasaki, O.
    Vallet-Regi, M.
    [J]. CHEMISTRY OF MATERIALS, 2009, 21 (06) : 1000 - 1009
  • [3] Magnetic-responsive delivery of drug-carriers using titania nanotube arrays
    Aw, Moom Sinn
    Addai-Mensah, Jonas
    Losic, Dusan
    [J]. JOURNAL OF MATERIALS CHEMISTRY, 2012, 22 (14) : 6561 - 6563
  • [4] A multi-drug delivery system with sequential release using titania nanotube arrays
    Aw, Moom Sinn
    Addai-Mensah, Jonas
    Losic, Dusan
    [J]. CHEMICAL COMMUNICATIONS, 2012, 48 (27) : 3348 - 3350
  • [5] Polymeric micelles in porous and nanotubular implants as a new system for extended delivery of poorly soluble drugs
    Aw, Moom Sinn
    Simovic, Spomenka
    Addai-Mensah, Jonas
    Losic, Dusan
    [J]. JOURNAL OF MATERIALS CHEMISTRY, 2011, 21 (20) : 7082 - 7089
  • [6] MANAGEMENT OF DEEP INFECTION OF TOTAL HIP-REPLACEMENT
    BUCHHOLZ, HW
    ELSON, RA
    ENGELBRECHT, E
    LODENKAMPER, H
    ROTTGER, J
    SIEGEL, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1981, 63 (03): : 342 - 353
  • [7] Ex vivo bone formation in bovine trabecular bone cultured in a dynamic 3D bioreactor is enhanced by compressive mechanical strain
    David, Valentin
    Guignandon, Alain
    Martin, Aline
    Malaval, Luc
    Lafage-Proust, Marie-Helene
    Rattner, Aline
    Mann, Val
    Noble, Brendon
    Jones, David B.
    Vico, Laurence
    [J]. TISSUE ENGINEERING PART A, 2008, 14 (01) : 117 - 126
  • [8] Mechanical loading down-regulates peroxisome proliferator-activated receptor γ in bone marrow stromal cells and favors osteoblastogenesis at the expense of adipogenesis
    David, Valentin
    Martin, Aline
    Lafage-Proust, Marie-Helene
    Malaval, Luc
    Peyroche, Sylvie
    Jones, David B.
    Vico, Laurence
    Guignandon, Alain
    [J]. ENDOCRINOLOGY, 2007, 148 (05) : 2553 - 2562
  • [9] Mechanically loaded ex vivo bone culture system 'Zetos':: Systems and culture preparation
    Davies, C. M.
    Jones, D. B.
    Stoddart, M. J.
    Koller, K.
    Smith, E.
    Archer, C. W.
    Richards, R. G.
    [J]. EUROPEAN CELLS & MATERIALS, 2006, 11 : 57 - 75
  • [10] Endres S, 2009, J MUSCULOSKEL NEURON, V9, P173