Potentiometric urea biosensor based on BSA embedded surface modified polypyrrole film

被引:59
作者
Ahuja, Tarushee [2 ]
Mir, Irfan Ahmad [2 ]
Kumar, Devendra [2 ]
Rajesh [1 ]
机构
[1] Special Inst Area, Council Sci & Ind Res, New Delhi 110067, India
[2] Univ Delhi, Delhi Coll Engn, Dept Appl Chem, Delhi 110042, India
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2008年 / 134卷 / 01期
关键词
Urea; Polymer; Biosensor; Enzyme; BSA; Peptide linkage;
D O I
10.1016/j.snb.2008.04.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A potentiometric biosensor based on bovine serum albumin (BSA) embedded surface modified polypyrrole has been developed for the quantitative estimation of urea in aqueous solution. The enzyme, urease (Urs), was covalently linked to free amino groups present over the BSA embedded modified surface of the conducting polypyrrole film electrochemically deposited onto an indium-tin-oxide (ITO) coated glass plate, The biosensor has been characterized by UV-visible, infrared spectroscopy and SEM. Potentiometric and spectrophotometric response of the enzyme electrode (Urs/BSA-PPy/ITO) were measured as a function of urea concentration in Tris-HCl buffer (pH 7.0). It has been found that the electrode responds to low urea concentration with wider range of detection. The electrode showed a linear response range of 6.6 x 10(-6) to 7.5 x 10(-4) M urea. The response time is about 70-90s reaching to a 95% steady-state potential value and 75% of the enzyme activity is retained for about 2 months. These results indicate an efficient covalent linkage of enzyme to free amino groups of the BSA molecules over the surface of polypyrrole film, which leads to high enzyme loading, ail increased lifetime stability of the electrode and an improved wide range of detection of low urea concentration in aqueous solution. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:140 / 145
页数:6
相关论文
共 41 条
  • [1] Polypyrrole-based amperometric flow injection biosensor for urea
    Adeloju, SB
    Shaw, SJ
    Wallace, GG
    [J]. ANALYTICA CHIMICA ACTA, 1996, 323 (1-3) : 107 - 113
  • [2] POLYPYRROLE-BASED POTENTIOMETRIC BIOSENSOR FOR UREA .2. ANALYTICAL OPTIMIZATION
    ADELOJU, SB
    SHAW, SJ
    WALLACE, GG
    [J]. ANALYTICA CHIMICA ACTA, 1993, 281 (03) : 621 - 627
  • [3] Biomolecular immobilization on conducting polymers for biosensing applications
    Ahuja, Tarushee
    Mir, Irfan Ahmad
    Kumar, Devendra
    Rajesh
    [J]. BIOMATERIALS, 2007, 28 (05) : 791 - 805
  • [4] Characterisation and analytical use of a polypyrrole electrode containing anti-human serum albumin
    Barisci, JN
    Hughes, D
    Minett, A
    Wallace, GG
    [J]. ANALYTICA CHIMICA ACTA, 1998, 371 (01) : 39 - 48
  • [5] CHARACTERIZATION OF BIOSENSORS BASED ON MEMBRANES CONTAINING A CONDUCTING POLYMER
    BATTILOTTI, M
    COLAPICCHIONI, C
    GIANNINI, I
    PORCELLI, F
    CAMPANELLA, L
    CORDATORE, M
    MAZZEI, F
    TOMASSETTI, M
    [J]. ANALYTICA CHIMICA ACTA, 1989, 221 (01) : 157 - 161
  • [6] Amperometric ammonium ion and urea determination with enzyme-based probes
    Bertocchi, P
    Compagnone, D
    Palleschi, G
    [J]. BIOSENSORS & BIOELECTRONICS, 1996, 11 (1-2) : 1 - 10
  • [7] Conductometric uric acid and urea biosensor prepared from electroconductive polyaniline-poly(n-butyl methacrylate) composites
    Castillo-Ortega, MM
    Rodriguez, DE
    Encinas, JC
    Plascencia, M
    Méndez-Velarde, FA
    Olayo, R
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 85 (1-2) : 19 - 25
  • [8] Enhancing the sensitivity and stability of HRP/PANI/Pt electrode by implanted bovine serum albumin
    Chen, Chien-Chung
    Gu, Yesong
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 23 (06) : 765 - 770
  • [9] Portable urea biosensor based on the extended-gate field effect transistor
    Chen, JC
    Chou, JC
    Sun, TP
    Hsiung, SK
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 91 (1-3) : 180 - 186
  • [10] An amperometric urea biosensor based on a polyaniline-perfluorosulfonated ionomer composite electrode
    Cho, WJ
    Huang, HJ
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (18) : 3946 - 3951