Magnetic resonance imaging guidance for the optimization of ventricular tachycardia ablation

被引:26
作者
Mukherjee, Rahul K. [1 ]
Whitaker, John [1 ]
Williams, Steven E. [1 ,2 ]
Razavi, Reza [1 ]
O'Neill, Mark D. [1 ,2 ]
机构
[1] Kings Coll London, St Thomas Hosp, Sch Biomed Engn & Imaging Sci, 4th Floor,North Wing, London SE1 7EH, England
[2] Guys & St Thomas Hosp NHS Fdn Trust, Dept Cardiol, London SE1 7EH, England
来源
EUROPACE | 2018年 / 20卷 / 11期
基金
英国惠康基金; 英国医学研究理事会;
关键词
Ventricular tachycardia; Cardiac magnetic resonance imaging; Substrate; Catheter ablation; Real time; Image integration; Active tracking; CHRONIC MYOCARDIAL-INFARCTION; ACTIVE CATHETER TRACKING; GADOLINIUM-ENHANCED MRI; CRITICAL ISTHMUS SITES; NONISCHEMIC CARDIOMYOPATHY; GUIDED ELECTROPHYSIOLOGY; SCAR TRANSMURALITY; SEPTAL PUNCTURE; PORCINE MODEL; CARDIAC MRI;
D O I
10.1093/europace/euy040
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Catheter ablation has an important role in the management of patients with ventricular tachycardia (VT) but is limited by modest long-term success rates. Magnetic resonance imaging (MRI) can provide valuable anatomic and functional information as well as potentially improve identification of target sites for ablation. A major limitation of current MRI protocols is the spatial resolution required to identify the areas of tissue responsible for VT but recent developments have led to new strategies which may improve substrate assessment. Potential ways in which detailed information gained from MRI may be utilized during electrophysiology procedures include image integration or performing a procedure under real-time MRI guidance. Image integration allows pre-procedural magnetic resonance (MR) images to be registered with electroanatomical maps to help guide VT ablation and has shown promise in preliminary studies. However, multiple errors can arise during this process due to the registration technique used, changes in ventricular geometry between the time of MRI and the ablation procedure, respiratory and cardiac motion. As isthmus sites may only be a few millimetres wide, reducing these errors may be critical to improve outcomes in VT ablation. Real-time MR-guided intervention has emerged as an alternative solution to address the limitations of pre-acquired imaging to guide ablation. There is now a growing body of literature describing the feasibility, techniques, and potential applications of real-time MR-guided electrophysiology. We review whether real-time MR-guided intervention could be applied in the setting of VT ablation and the potential challenges that need to be overcome.
引用
收藏
页码:1721 / 1732
页数:12
相关论文
共 83 条
[1]   3D delayed-enhanced magnetic resonance sequences improve conducting channel delineation prior to ventricular tachycardia ablation [J].
Andreu, David ;
Ortiz-Perez, Jose T. ;
Fernandez-Armenta, Juan ;
Guiu, Esther ;
Acosta, Juan ;
Prat-Gonzalez, Susanna ;
De Caralt, Teresa M. ;
Perea, Rosario J. ;
Garrido, Cesar ;
Mont, Lluis ;
Brugada, Josep ;
Berruezo, Antonio .
EUROPACE, 2015, 17 (06) :938-945
[2]   Usefulness of contrast-enhanced cardiac magnetic resonance in identifying the ventricular arrhythmia substrate and the approach needed for ablation [J].
Andreu, David ;
Tomas Ortiz-Perez, Jose ;
Boussy, Tim ;
Fernandez-Armenta, Juan ;
de Caralt, Teresa M. ;
Perea, Rosario J. ;
Prat-Gonzalez, Susanna ;
Mont, Lluis ;
Brugada, Josep ;
Berruezo, Antonio .
EUROPEAN HEART JOURNAL, 2014, 35 (20) :1316-1326
[3]   Integration of 3D Electroanatomic Maps and Magnetic Resonance Scar Characterization Into the Navigation System to Guide Ventricular Tachycardia Ablation [J].
Andreu, David ;
Berruezo, Antonio ;
Ortiz-Perez, Jose T. ;
Silva, Etelvino ;
Mont, Lluis ;
Borras, Roger ;
Maria de Caralt, Teresa ;
Jesus Perea, Rosario ;
Fernandez-Armenta, Juan ;
Zeljko, Hrvojka ;
Brugada, Josep .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (05) :674-683
[4]  
Androulakis AFA, 2017, EUR HEART J, V38, P413
[5]   High-Resolution Mapping of Postinfarction Reentrant Ventricular Tachycardia Electrophysiological Characterization of the Circuit [J].
Anter, Elad ;
Tschabrunn, Cory M. ;
Buxton, Alfred E. ;
Josephson, Mark E. .
CIRCULATION, 2016, 134 (04) :314-+
[6]   Magnetic resonance image-guided trans-septal puncture in a swine heart [J].
Arepally, A ;
Karmarkar, PV ;
Weiss, C ;
Rodriguez, ER ;
Lederman, RJ ;
Atalar, E .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) :463-467
[7]   Magnetic resonance-based anatomical analysis of scar-related ventricular tachycardia -: Implications for catheter ablation [J].
Ashikaga, Hiroshi ;
Sasano, Tetsuo ;
Dong, Jun ;
Zviman, M. Muz ;
Evers, Robert ;
Hopenfeld, Bruce ;
Castro, Valeria ;
Helm, Robert H. ;
Dickfeld, Timm ;
Nazarian, Saman ;
Donahue, J. Kevin ;
Berger, Ronald D. ;
Calkins, Hugh ;
Abraham, M. Roselle ;
Marbán, Eduardo ;
Lardo, Albert C. ;
McVeigh, Elliot R. ;
Halperin, Henry R. .
CIRCULATION RESEARCH, 2007, 101 (09) :939-947
[8]   Improved dark blood late gadolinium enhancement (DB-LGE) imaging using an optimized joint inversion preparation and T2 magnetization preparation [J].
Basha, Tamer A. ;
Tang, Maxine C. ;
Tsao, Connie ;
Tschabrunn, Cory M. ;
Anter, Elad ;
Manning, Warren J. ;
Nezafat, Reza .
MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) :351-360
[9]   Clinical Performance of High-Resolution Late Gadolinium Enhancement Imaging With Compressed Sensing [J].
Basha, Tamer A. ;
Akcakaya, Mehmet ;
Liew, Charlene ;
Tsao, Connie W. ;
Delling, Francesca N. ;
Addae, Gifty ;
Ngo, Long ;
Manning, Warren J. ;
Nezafat, Reza .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (06) :1829-1838
[10]   Delayed-Enhanced Magnetic Resonance Imaging in Nonischemic Cardiomyopathy Utility for Identifying the Ventricular Arrhythmia Substrate [J].
Bogun, Frank M. ;
Desjardins, Benoit ;
Good, Eric ;
Gupta, Sanjaya ;
Crawford, Thomas ;
Oral, Hakan ;
Ebinger, Matthew ;
Pelosi, Frank ;
Chugh, Aman ;
Jongnarangsin, Krit ;
Morady, Fred .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (13) :1138-1145