One-Year Results of a Randomized Controlled Clinical Trial of Immediately Loaded Short Implants Placed in the Lower Posterior Single Molar Using a Complete Digital Workflow

被引:3
作者
Baek, Yeon-Wha [1 ,2 ]
Lim, Young-Jun [1 ,2 ]
Lee, Jungwon [3 ]
Koo, Ki-Tae [2 ,4 ]
Kim, Myung-Joo [1 ,2 ]
Kwon, Ho-Beom [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Prosthodont, Seoul 03080, South Korea
[2] Seoul Natl Univ, Sch Dent, Dent Res Inst, Seoul 03080, South Korea
[3] Seoul Natl Univ, Dent Hosp, One Stop Specialty Ctr, Dept Periodont, Seoul 03080, South Korea
[4] Seoul Natl Univ, Sch Dent, Dept Periodontol, Seoul 03080, South Korea
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 07期
关键词
dental implants; short dental implants; immediate loading; primary stability; digital work flow; RESONANCE-FREQUENCY-ANALYSIS; SHORT DENTAL IMPLANTS; LONG-TERM OUTCOMES; LOADING PROTOCOLS; BONE AUGMENTATION; PROSPECTIVE MULTICENTER; STABILITY; SURGERY; CROWNS; SURVIVAL;
D O I
10.3390/app9071282
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The purpose of this randomized clinical trial is to evaluate immediately loaded single implants with varying lengths in the posterior mandible using a fully digital, model-free prosthetic-driven implant planning pathway, and to compare clinical and radiological outcomes of short and long implants. The 52 patients with the single tooth missing in the posterior molar regions of the mandible were randomly assigned to the control (CMI IS-III active((R)) long implant; 5.0 x 10 mm) and experimental (CMI IS-III active((R)) short implant; 5.5 x 6.6, 7.3, 8.5 mm) groups. For each patient, a single implant was placed using the computer aided surgical template and all prostheses were fabricated by means of computer-aided design/computer-aided manufacturing (CAD/CAM) system on the virtual model. The patients received provisional and definitive monolithic zirconia prostheses at 1 week and 12 weeks after implant surgery, respectively. The implant stability quotient (ISQ) measurements and periapical radiographs were taken and peri-implant parameters were evaluated at 1, 3, 4, 8, 12, 24, 36, and 48 weeks after surgery. Nineteen long implants and 27 short implants were finally used for the statistical analysis. There was no significant difference between the groups in terms of insertion torque, ISQ values (except 3 weeks), marginal bone loss, and peri-implant soft tissue parameters (p > 0.05). Both groups exhibited no stability dip during the early phase of healing. The average marginal bone loss from the baseline of implant placement for the control and experimental groups was -0.07 and 0.03 mm after 12 weeks and 0.06 and 0.05 mm after 48 weeks. All of the soft tissue parameters were within normal limits. Within the limits of the short term follow up, immediate loading of short single implants can be considered as one of predictable treatment modality in mandible with reduced bone height when primary stability can be achieved.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Ten-year hard and soft tissue results ofa pilot double-blinded randomized controlled trial on immediately loaded post-extractive implants using platform-switching concept
    Canullo, Luigi
    Caneva, Martina
    Tallarico, Marco
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (10) : 1195 - 1203
  • [42] Posterior atrophic jaws rehabilitated with prostheses supported by 6 mm long 4 mm wide implants or by longer implants in augmented bone. One-year post-loading results from a pilot randomised controlled trial
    Pistilli, Roberto
    Felice, Pietro
    Cannizzaro, Gioacchino
    Piattelli, Maurizio
    Corvino, Valeria
    Barausse, Carlo
    Buti, Jacopo
    Soardi, Elisa
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2013, 6 (04) : 359 - 372
  • [43] Accuracy, Labor-Time and Patient-Reported Outcomes with Partially versus Fully Digital Workflow for Flapless Guided Dental Implants Insertion-A Randomized Clinical Trial with One-Year Follow-Up
    Cristache, Corina Marilena
    Burlibasa, Mihai
    Tudor, Ioana
    Totu, Eugenia Eftimie
    Di Francesco, Fabrizio
    Moraru, Liliana
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (05) : 1 - 18
  • [44] Randomized controlled clinical trial of customized zirconia and titanium implant abutments for canine and posterior single-tooth implant reconstructions: preliminary results at 1 year of function
    Sailer, Irena
    Zembic, Anja
    Jung, Ronald Ernst
    Siegenthaler, David
    Holderegger, Claudia
    Haemmerle, Christoph Hans Franz
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (03) : 219 - 225
  • [45] Immediate fixed rehabilitation of severe maxillary atrophies using trans-sinus tilted implants with or without sinus bone grafting: One-year results from a randomised controlled trial
    Grandi, Tommaso
    Faustini, Fabio
    Casotto, Filippo
    Samarani, Rawad
    Svezia, Luigi
    Radano, Paolo
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2019, 12 (02) : 141 - 152
  • [46] Posterior atrophic jaws rehabilitated with prostheses supported by 5 x 5 mm implants with a novel nanostructured calcium-incorporated titanium surface or by longer implants in augmented bone. One-year results from a randomised controlled trial
    Pistilli, Roberto
    Felice, Pietro
    Piattelli, Maurizio
    Gessaroli, Manlio
    Soardi, Elisa
    Barausse, Carlo
    Buti, Jacopo
    Corvino, Valeria
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2013, 6 (04) : 343 - 357
  • [47] Clinical and Radiographic Outcomes of Single Implant-Supported Zirconia Crowns Following a Digital and Conventional Workflow: Four-Year Follow-Up of a Randomized Controlled Clinical Trial
    Beck, Florian
    Cepic, Lana Zupancic
    Lettner, Stefan
    Moritz, Andreas
    Ulm, Christian
    Zechner, Werner
    Schedle, Andreas
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (02)
  • [48] Immediate and delayed loading of two-piece reduced-diameter implants with locator-analog attachments in edentulous mandibles: One-year results from a randomized clinical trial examining clinical outcome and patient expectation
    Giannakopoulos, Nikolaos Nikitas
    Ariaans, Kirsten
    Eberhard, Lydia
    Klotz, Anna-Luisa
    Oh, Keunyoung
    Kappel, Stefanie
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (04) : 643 - 653
  • [49] Comparison between Early Loaded Single Implants with Internal Conical Connection or Implants with Transmucosal Neck Design: A Non-Randomized Controlled Trial with 1-Year Clinical, Aesthetics, and Radiographic Evaluation
    Ceruso, Francesco Mattia
    Ieria, Irene
    Tallarico, Marco
    Meloni, Silvio Mario
    Lumbau, Aurea Immacolata
    Mastroianni, Alessandro
    Zotti, Alessio
    Gargari, Marco
    MATERIALS, 2022, 15 (02)
  • [50] Papilla dimension and soft tissue level after early vs. delayed placement of single-tooth implants: 10-year results from a randomized controlled clinical trial
    Schropp, Lars
    Isidor, Flemming
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (03) : 278 - 286