Three-dimensional color Doppler for assessing mitral regurgitation during valvuloplasty

被引:14
作者
De Simone, R [1 ]
Glombitza, G [1 ]
Vahl, CF [1 ]
Albers, J [1 ]
Meinzer, HP [1 ]
Hagl, S [1 ]
机构
[1] Univ Heidelberg, Abt Herzchirurg, Dept Cardiac Surg, D-69120 Heidelberg, Germany
关键词
mitral valve regurgitation; mitral valvuloplasty; color Doppler echocardiography; transesophageal echocardiography; intraoperative echocardiography; three-dimensional color Doppler;
D O I
10.1016/S1010-7940(98)00312-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Transesophageal color Doppler (or 2D Doppler) is the most widely used technique for intraoperative assessment of mitral valve repair. However, the most severe mitral regurgitations produce eccentric jet flows which cannot be assessed by 2D imaging. Up to now the indications for surgical intervention and intraoperative decisions after valve repair have been based on 2D Doppler examinations. Aim of this study was to compare conventional 2D Doppler to three-dimensional (3D) Doppler for assessing residual regurgitation in patients after mitral valvuloplasty. Methods: Twenty-four patients were referred to surgery for mitral valve repair. They underwent transesophageal echocardiography and 3D data acquisition during mitral valve reconstruction. Conventional assessment of mitral valve regurgitation, measured by color Doppler jet area, was compared to the volume of regurgitant jets obtained by 3D Doppler. Regurgitant volume and fraction were measured by pulsed Doppler and two-dimensional echocardiography. The 3D reconstructions of color Doppler data were accomplished by means of the 'Heidelberg Raytracing Algorithm' developed at our institution. Results: The jet areas did not show any significant correlation to the regurgitant fraction (r = 45; P = NS) or regurgitant volumes (r = 0.40; P = NS). In contrast the jet volumes correlated significantly to regurgitant fraction (r = 0.71; P < 0.01) and regurgitant volume (r = 0.85; P < 0.01). The reproducibility analysis of repeated jet volume and jet area measurements also showed that the parameter jet volume has a lower variability and higher agreement of repeated measurements than jet area. Conclusions: Three-dimensional color Doppler flow imaging revealed the complex geometry of eccentric regurgitant jets and showed that the assessment of mitral regurgitation, based on conventional 2D Doppler, can be misleading. This new technique has a great potential for becoming a reference method for assessing mitral valve repair. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 25 条
[11]   ADJUSTABLE TRICUSPID-VALVE ANNULOPLASTY ASSISTED BY INTRAOPERATIVE TRANSESOPHAGEAL COLOR DOPPLER ECHOCARDIOGRAPHY [J].
DESIMONE, R ;
LANGE, R ;
TANZEEM, A ;
GAMS, E ;
HAGL, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (11) :926-931
[12]  
DESIMONE R, 1997, ECHOCARDIOGR-J CARD, V14, pS31
[13]  
DESIMONE R, 1994, ATLAS TRANSESOPHAGEA
[14]  
DESIMONE R, 1998, IN PRESS ASSESSMENT
[15]   PULSED DOPPLER ECHOCARDIOGRAPHIC DETERMINATION OF STROKE VOLUME AND CARDIAC-OUTPUT - CLINICAL VALIDATION OF 2 NEW METHODS USING THE APICAL WINDOW [J].
LEWIS, JF ;
KUO, LC ;
NELSON, JG ;
LIMACHER, MC ;
QUINONES, MA .
CIRCULATION, 1984, 70 (03) :425-431
[16]   INTRAOPERATIVE DOPPLER COLOR FLOW MAPPING FOR ASSESSMENT OF VALVE REPAIR FOR MITRAL REGURGITATION [J].
MAURER, G ;
CZER, LSC ;
CHAUX, A ;
BOLGER, AF ;
DEROBERTIS, M ;
RESSER, K ;
KASS, RM ;
LEE, ME ;
MATLOFF, JM .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (04) :333-337
[17]  
MEINZER HP, 1991, IEEE COMPUT GRAPH, V6, P34
[18]   SEMIQUANTITATIVE GRADING OF SEVERITY OF MITRAL REGURGITATION BY REAL-TIME TWO-DIMENSIONAL DOPPLER FLOW IMAGING TECHNIQUE [J].
MIYATAKE, K ;
IZUMI, S ;
OKAMOTO, M ;
KINOSHITA, N ;
ASONUMA, H ;
NAKAGAWA, H ;
YAMAMOTO, K ;
TAKAMIYA, M ;
SAKAKIBARA, H ;
NIMURA, Y .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (01) :82-88
[19]  
OMOTO R, 1984, JPN HEART J, V25, P325
[20]   REAL-TIME TWO-DIMENSIONAL DOPPLER ECHOCARDIOGRAPHIC FLOW MAPPING [J].
SAHN, DJ .
CIRCULATION, 1985, 71 (05) :849-853