Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study

被引:2
作者
Liu, Xuexiu [1 ]
Tao, Xiaojun [1 ]
Xu, Ye [2 ]
Zhang, Xianhong [1 ]
Chen, Yanhan [3 ]
Wu, Liping [4 ]
机构
[1] Chongqing Med Univ, Dept Neonatol, Childrens Hosp, Chongqing, Peoples R China
[2] China Int Sci & Technol Cooperat Base Child Dev &, Radiol Dept, Chongqing Key Lab Pediat, Chongqing, Peoples R China
[3] Chongqing Med Univ, Coll Nursing, Chongqing, Peoples R China
[4] Chongqing Med Univ, Dept Nursing, Childrens Hosp, Chongqing, Peoples R China
关键词
peripherally inserted central catheter; ultrasonography; chest radiography; positioning; neonate; CENTRAL VENOUS CATHETERS; ULTRASOUND; PLACEMENT; ECHOCARDIOGRAPHY; INFANTS;
D O I
10.3389/fped.2022.976826
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
ObjectiveThis study aimed to compare the applications of bedside ultrasonography (US) and bedside chest radiography (CR) in positioning peripherally inserted central venous catheter (PICC) at Neonatal Intensive Care Units (NICUs). MethodsThe study is a prospective before and after self-control clinical trial. A consecutive series of 181 neonate patients were finally enrolled for PICC placement. CR, followed by US, was used to evaluate and readjust the sites of catheter tips. The imaging capability for PICC key structures, fluctuation of the measured data, measurement of tip-to-atrium distance, operation time, infants' body temperature changes, and direct expenses of the two imaging modalities were obtained and compared. Results(1) Comparison in viewing PICC key structures: the display rate of catheter tip, SVC-and-right-atrium junction, IVC-and-right-atrium junction and tip-to-atrium distance is 99.47%, 100%, 100% and 99.47% for US and 100%, 98.42%, 97.37% and 95.79% for CR, respectively. (2) Fluctuation of the measured data by US and CR: the tip-to-atrium distance measured by US is 0.631 (0.435-0.820) cm, and that measured by CR is 0.593 (0.210-0.825) cm. US showed a narrower range of datum variance. (3) Consistency between US and CR: for consistency analysis, the Kappa coefficient (kappa) was 0.843 (P < 0.05), showing their favorable consistency. (4) Comparison of operation time and infants' body temperature drop: for a CR exam, the time period taken was significantly longer than that of US (59.7 +/- 26.33 vs. 79.6 +/- 28.06, P < 0.001); and CR operations caused a significant babies' body temperature drop compared to US (0.14 +/- 0.11 vs. 0.34 +/- 0.19, P < 0.001). (5) Comparison of the direct expenses: the total cost for CR positioning was significantly higher than that for US ( yen 153.99 vs. yen 143, P = 0.026). ConclusionUS exhibited superior traits to CR in the positioning of PICC tip. It could be promising for routine use in NICU.
引用
收藏
页数:8
相关论文
共 26 条
[1]   Peripherally inserted central venous catheters in newborn infants: Malpositioning and spontaneous correction of catheter tips [J].
Al Tawil, K ;
Eldemerdash, A ;
Al Hathlol, K ;
Abu Laimoun, L .
AMERICAN JOURNAL OF PERINATOLOGY, 2006, 23 (01) :37-40
[2]   Neo-ECHOTIP: A structured protocol for ultrasound-based tip navigation and tip location during placement of central venous access devices in neonates [J].
Barone, Giovanni ;
Pittiruti, Mauro ;
Biasucci, Daniele G. ;
Elisei, Daniele ;
Iacobone, Emanuele ;
La Greca, Antonio ;
Zito Marinosci, Geremia ;
D'Andrea, Vito .
JOURNAL OF VASCULAR ACCESS, 2022, 23 (05) :679-688
[3]  
Barton Andrew, 2016, Br J Nurs, V25, pS17, DOI 10.12968/bjon.2016.25.Sup2.S17
[4]   Radiation exposure from diagnostic procedures following allogeneic stem cell transplantation - How much is acceptable? [J].
Battiwalla, Minoo ;
Fakhrejahani, Farhad ;
Jain, Natasha A. ;
Klotz, Jeffrey K. ;
Pophali, Priyanka A. ;
Draper, Debbie ;
Haggerty, Janice ;
McIver, Zachariah ;
Jelinek, James ;
Chawla, Kamna ;
Ito, Sawa ;
Barrett, John .
HEMATOLOGY, 2014, 19 (05) :275-279
[5]   Peripherally Inserted Central Catheters Complicated by Vascular Erosion in Neonates [J].
Blackwood, Brian P. ;
Farrow, Kathryn N. ;
Kim, Stan ;
Hunter, Catherine J. .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2016, 40 (06) :890-895
[6]   Influence of arm movement on central tip location of peripherally inserted central catheters (PICCs) [J].
Connolly, Bairbre ;
Amaral, Joao ;
Walsh, Sharon ;
Temple, Michael ;
Chait, Peter ;
Stephens, Derek .
PEDIATRIC RADIOLOGY, 2006, 36 (08) :845-850
[7]  
Evidence-Based Medicine Group Neonatologist Society Chinese Medical Doctor Association, 2021, Zhongguo Dang Dai Er Ke Za Zhi, V23, P201
[8]   Section One: Infusion Therapy Practice [J].
不详 .
JOURNAL OF INFUSION NURSING, 2021, 44 :S13-S42
[9]  
Han Zhenzhen, 2020, Zhongguo Yi Liao Qi Xie Za Zhi, V44, P56, DOI 10.3969/j.issn.1671-7104.2020.01.012
[10]   Effect of heparin and other factors associated with complications of peripherally inserted central venous catheters in neonates [J].
Isemann, B. ;
Sorrels, R. ;
Akinbi, H. .
JOURNAL OF PERINATOLOGY, 2012, 32 (11) :856-860