Application of common transformers faults diagnosis methods on biodegradable oil-filled transformers

被引:13
|
作者
Muhamad, N. A. [1 ]
Phung, B. T. [2 ]
Blackburn, T. R. [2 ]
机构
[1] Univ Technol Malaysia, Skudai, Johor, Malaysia
[2] Univ New S Wales, Kensington, NSW 2033, Australia
关键词
Oil-filled transformers; Biodegradable oil; Mineral oil; Transformer faults; Insulation diagnostics; Dissolved gas-in-oil analysis; Partial discharge;
D O I
10.1007/s00202-012-0232-z
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Due to environmental concerns regarding the use of mineral oil, biodegradable oil is increasingly being used as an alternative dielectric fluid. This paper presents results of experiments performed in the laboratory on the use of biodegradable oils for transformer application. The investigations cover two important diagnostic techniques for insulation assessment: (i) an investigation of partial discharge (PD) activity and characteristics in such oils and (ii) an investigation of the standard hydrocarbon dissolved gas products produced due to transformer faults. The fundamental aim of the investigation was to provide information as to whether the existing analysis techniques of PD fault pattern recognition and dissolved gas analysis methods, developed for mineral oil, are valid when used for insulation assessment with biodegradable transformer oil. The experiments were conducted on test samples to simulate three common types of transformer faults: low-energy PDs, high-energy arcing/sparking, and overheating. For the purpose of comparison, the same tests were performed using a mineral oil (Shell Diala MX) and a biodegradable oil (Envirotemp FR3). Also, each oil type was tested at three different moisture levels and with or without the presence of solid insulating materials (pressboard). PD activity was monitored using the standard IEC60270 phase-resolved analysis method. The fault gases produced were extracted and analysed by standard gas chromatography methods. Test results indicate that the PD phase resolved patterns are, in general, similar for the two oil types and thus existing PD pattern interpretations can be used to distinguish different types of PD faults, e.g. corona versus surface discharges. However, the values of various discharge quantities (PD magnitudes, repetition rate, current, etc) are very different under the same test condition. The quantities and the trend of dissolved gases for faults in biodegradable oil are substantially different compared with mineral oil. For the PD fault, biodegradable oil was found to release only a limited number of gases. For arcing and overheating faults, the main key gas produced is different between the two oils. Also, the presence of cellulosic materials such as pressboard influences the extent of hydrocarbon gases dissolved in the oil. It was found that for biodegradable oil, fewer amounts of gases are produced as the oil gets wetter.
引用
收藏
页码:207 / 216
页数:10
相关论文
共 50 条
  • [41] CONTINUOUS, ONLINE MONITORING OF FREESTANDING, OIL-FILLED CURRENT TRANSFORMERS TO PREDICT IMMINENT FAILURE
    CUMMINGS, HB
    BOYLE, JR
    ARP, BW
    IEEE TRANSACTIONS ON POWER DELIVERY, 1988, 3 (04) : 1776 - 1783
  • [42] Characterization of UHF PD Sensors for Power Transformers Using an Oil-filled GTEM Cell
    Siegel, Martin
    Beltle, Michael
    Tenbohlen, Stefan
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (03) : 1580 - 1588
  • [43] Virtual instrumentation and its application in diagnosis of faults in power transformers
    Vanaja, R
    Udayakumar, K
    Lokesh, K
    IEEE 2000 TENCON PROCEEDINGS, VOLS I-III: INTELLIGENT SYSTEMS AND TECHNOLOGIES FOR THE NEW MILLENNIUM, 2000, : A598 - A602
  • [44] Improving accuracy of DGA interpreation of oil-filled power transformers needed for effective condition monitoring
    Suleiman, Abubakar A.
    Alghamdi, Ali S.
    Mohamad, Nor Asiah
    Bashir, Nouruddeen
    Aizam, Mohd
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 374 - 378
  • [45] Estimating the DP Value of the Paper Insulation of Oil-Filled Power Transformers Using an ANFIS Algorithm
    Rhamadhan, Firza Zulmi
    Kinkeldey, Tobias
    Werle, Peter
    Suwarno
    2021 11TH INTERNATIONAL CONFERENCE ON POWER, ENERGY AND ELECTRICAL ENGINEERING (CPEEE 2021), 2021, : 202 - 207
  • [46] Cellulose insulation in oil-filled power transformers: Part II - Maintaining insulation integrity and life
    Oommen, TV
    Prevost, TA
    IEEE ELECTRICAL INSULATION MAGAZINE, 2006, 22 (02) : 5 - 14
  • [47] Enhanced Method for Localization of Partial Discharges in Oil-Filled Transformers Using Acoustic Emission Signals
    Otake, Yasutomo
    Tajiri, Kunihiko
    INTERNATIONAL JOURNAL OF PROGNOSTICS AND HEALTH MANAGEMENT, 2024, 15 (03)
  • [48] Analysis of test norm requirements for oil-filled entrance bushings and current transformers during operation
    Polyakov V.S.
    Goldstein V.G.
    Dadonov D.N.
    Russian Electrical Engineering, 2009, 80 (7) : 388 - 391
  • [49] Research of Insulation Properties of Polymer Materials Using In Oil-Filled Transformers under High Temperature
    Tu, Youping
    Sun, Weizhong
    Yue, Caipeng
    Chen, Guanghui
    Wang, Wei
    2011 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 2011, : 583 - 586
  • [50] On Approaching Relevant Cost-Effective Sustainable Maintenance of Mineral Oil-Filled Electrical Transformers
    Jadim, Ramsey
    Kans, Mirka
    Schulte, Jesko
    Alhattab, Mohammed
    Alhendi, May
    Bushehry, Ali
    ENERGIES, 2021, 14 (12)