A cellulose-based photoacoustic sensor to measure heparin concentration and activity in human blood samples

被引:29
作者
Jeevarathinam, Ananthakrishnan Soundaram [1 ]
Pai, Navin [1 ]
Huang, Kevin [1 ]
Hariri, Ali [1 ]
Wang, Junxin [1 ]
Bai, Yuting [1 ]
Wang, Lu [1 ]
Hancock, Tiffany [4 ]
Keys, Stanley [4 ]
Penny, William [4 ]
Jokerst, Jesse V. [1 ,2 ,3 ]
机构
[1] Univ Calif San Diego, Dept NanoEngn, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Mat Sci Program, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Dept Radiol, La Jolla, CA 92093 USA
[4] VA Healthcare Syst, Cardiol Unit, La Jolla, CA 92161 USA
基金
美国国家卫生研究院;
关键词
Heparin sensing; Photoacoustic imaging; Ultrasound; Anticoagulation therapy; Cellulose based sensor; PARTIAL THROMBOPLASTIN TIME; CHONDROITIN SULFATE CONTAMINANT; ACTIVATED CLOTTING TIME; UNFRACTIONATED HEPARIN; BLUE; SYSTEM; PROBES; ASSAY;
D O I
10.1016/j.bios.2018.11.052
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Heparin is an indispensable drug in anticoagulation therapy but with a narrow therapeutic window, which dictates regular testing and dose adjustment. However, current monitoring tools have a long turnaround time or are operator intensive. In this work, we describe a cellulose-based photoacoustic sensor for heparin. The sensors have a turnaround time of 6 min for whole blood samples and 3 min for plasma samples regardless of heparin concentration. These sensors have a limit of detection of 0.28 U/ml] heparin in human plasma and 0.29 U/ml in whole blood with a linear response (Pearson's r = 0.99) from 0 to 2 U/ml heparin in plasma and blood samples. The relative standard deviation was < 12.5% in plasma and < 17.5% in whole blood. This approach was validated with heparin-spiked whole human blood and had a linear correlation with the activated partial thromboplastin time (aPTT) (r = 0.99). We then studied 16 sets of clinical samples these had a linear correlation with the activated clotting time (ACT) (Pearson's r = 0.86, P < 0.0001). The photoacoustic signal was also validated against the cumulative heparin dose (Pearson's r = 0.71, P < 0.0001). This approach could have applications in bed-side heparin assays for continuous heparin monitoring.
引用
收藏
页码:831 / 837
页数:7
相关论文
共 54 条
[11]   Mallard Blue: A High-Affinity Selective Heparin Sensor That Operates in Highly Competitive Media [J].
Bromfield, Stephen M. ;
Barnard, Anna ;
Posocco, Paola ;
Fermeglia, Maurizio ;
Pricl, Sabrina ;
Smith, David K. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2013, 135 (08) :2911-2914
[12]   OPTIMIZATION OF AN ALCIAN BLUE DOT-BLOT ASSAY FOR THE DETECTION OF GLYCOSAMINOGLYCANS AND PROTEOGLYCANS [J].
BUEE, L ;
BOYLE, NJ ;
ZHANG, LB ;
DELACOURTE, A ;
FILLIT, HM .
ANALYTICAL BIOCHEMISTRY, 1991, 195 (02) :238-242
[13]   Non-enzymatic electrochemical detection of glucose with a disposable paper-based sensor using a cobalt phthalocyanine ionic liquid graphene composite [J].
Chaiyo, Sudkate ;
Mehmeti, Eda ;
Siangproh, Weena ;
Thai Long Hoang ;
Hai Phong Nguyen ;
Chailapakul, Orawon ;
Kalcher, Kurt .
BIOSENSORS & BIOELECTRONICS, 2018, 102 :113-120
[14]   ZnO Film Bulk Acoustic Resonator for the Kinetics Study of Human Blood Coagulation [J].
Chen, Da ;
Zhang, Zhen ;
Ma, Jilong ;
Wang, Wei .
SENSORS, 2017, 17 (05)
[15]   Micro-electromechanical film bulk acoustic sensor for plasma and whole blood coagulation monitoring [J].
Chen, Da ;
Song, Shuren ;
Ma, Jilong ;
Zhang, Zhen ;
Wang, Peng ;
Liu, Weihui ;
Guo, Qiuquan .
BIOSENSORS & BIOELECTRONICS, 2017, 91 :465-471
[16]  
Farooq M S, 2014, Drug Res (Stuttg), V64, P695, DOI 10.1055/s-0034-1368727
[17]   STUDIES ON THE CONFORMATION OF HEPARIN BY H-1 AND C-13 NMR-SPECTROSCOPY [J].
GATTI, G ;
CASU, B ;
HAMER, GK ;
PERLIN, AS .
MACROMOLECULES, 1979, 12 (05) :1001-1007
[18]   Direct-acting oral anticoagulants: pharmacology, indications, management, and future perspectives [J].
Gomez-Outes, Antonio ;
Luisa Suarez-Gea, M. ;
Lecumberri, Ramon ;
Isabel Terleira-Fernandez, Ana ;
Vargas-Castrillon, Emilio .
EUROPEAN JOURNAL OF HAEMATOLOGY, 2015, 95 (05) :389-404
[19]   Low-molecular-weight heparins compared with unfractionated heparin for treatment of acute deep venous thrombosis - A meta-analysis of randomized, controlled trials [J].
Gould, MK ;
Dembitzer, AD ;
Doyle, RL ;
Hastie, TJ ;
Garber, AM .
ANNALS OF INTERNAL MEDICINE, 1999, 130 (10) :800-+
[20]   The characterization of an economic and portable LED-based photoacoustic imaging system to facilitate molecular imaging [J].
Hariri, Ali ;
Lemaster, Jeanne ;
Wang, Junxin ;
Jeevarathinam, AnanthaKrishnan S. ;
Chao, Daniel L. ;
Jokerst, Jesse V. .
PHOTOACOUSTICS, 2018, 9 :10-20