Cardiac output monitoring devices: an analytic review

被引:12
|
作者
Porhomayon, Jahan [1 ]
El-Solh, Ali [2 ]
Papadakos, Peter [3 ]
Nader, Nader Djalal [1 ]
机构
[1] SUNY Buffalo, Sch Med & Biomed Sci, Dept Anesthesiol, VA Western New York Healthcare Syst, Buffalo, NY 14215 USA
[2] SUNY Buffalo, Sch Med & Biomed Sci, Div Pulm, Dept Med Crit Care & Sleep Med,VA Western New Yor, Buffalo, NY 14215 USA
[3] Univ Rochester, Crit Care Med & Trauma Intens Care Unit, Div Anesthesiol Crit Care Med, Strong Mem Hosp, Rochester, NY USA
关键词
Cardiac output; FloTrac; LiDCO; Esophageal Doppler; Echocardiography; ECOM; PiCCO; Pulmonary artery catheter; PULMONARY-ARTERY CATHETER; WAVE-FORM ANALYSIS; EXTRAVASCULAR LUNG WATER; PULSE-CONTOUR ANALYSIS; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; THERMODILUTION; SYSTEM; VOLUME; MANAGEMENT; VALIDITY;
D O I
10.1007/s11739-011-0738-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate cardiac output (CO), both invasive and semi-invasive monitors are used in critical care medicine. The pulmonary artery catheter is an invasive tool to assess CO with the major criticism that the level of its invasiveness is not supported by an improvement in patients' outcomes. The interest in a lesser invasive techniques is high. Therefore, alternative techniques have been developed recently, and are used frequently in critical care medicine. Cardiac output can be monitored continuously by different devices that analyze the stroke volume and CO. The purpose of this review is to understand these new technologies and their applications and limitations.
引用
收藏
页码:163 / 171
页数:9
相关论文
共 50 条
  • [41] Haemodynamic monitoring or output cardiac monitoring? Reply
    Brissaud, O.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2011, 30 (01): : 87 - 87
  • [42] NONINVASIVE MONITORING OF CARDIAC-OUTPUT BY DOPPLER-ECHOCARDIOGRAPHY IN PATIENTS TREATED WITH VOLUME EXPANSION AFTER SUBARACHNOID HEMORRHAGE
    MAYER, SA
    SHERMAN, D
    FINK, ME
    HOMMA, S
    SOLOMON, RA
    LENNIHAN, L
    BECKFORD, A
    KLEBANOFF, LM
    CRITICAL CARE MEDICINE, 1995, 23 (09) : 1470 - 1474
  • [43] A pilot assessment of the FloTracTM cardiac output monitoring system
    Helen Ingrid Opdam
    Li Wan
    Rinaldo Bellomo
    Intensive Care Medicine, 2007, 33 : 344 - 349
  • [44] Minimally Invasive Cardiac Output Monitoring in the Perioperative Setting
    Funk, Duane J.
    Moretti, Eugene W.
    Gan, Tong J.
    ANESTHESIA AND ANALGESIA, 2009, 108 (03) : 887 - 897
  • [45] A pilot assessment of the FloTrac™ cardiac output monitoring system
    Opdam, Helen Ingrid
    Wan, Li
    Bellomo, Rinaldo
    INTENSIVE CARE MEDICINE, 2007, 33 (02) : 344 - 349
  • [46] Semicontinuous cardiac output monitoring using a neural network
    Healey, C
    Orr, J
    Westenskow, D
    CRITICAL CARE MEDICINE, 1999, 27 (08) : 1505 - 1510
  • [47] Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output
    Sumit Vasdev
    Sandeep Chauhan
    Minati Choudhury
    Millind P. Hote
    Madhur Malik
    Usha Kiran
    Journal of Clinical Monitoring and Computing, 2012, 26 : 115 - 120
  • [48] A comparison of three minimally invasive cardiac output devices with thermodilution in elective cardiac surgery
    Phan, T. D.
    Kluger, R.
    Wan, C.
    Wong, D.
    Padayachee, A.
    ANAESTHESIA AND INTENSIVE CARE, 2011, 39 (06) : 1014 - 1021
  • [49] Use of minimally invasive hemodynamic monitoring to assess dynamic changes in cardiac output at the bedside
    Michael R Pinsky
    Critical Care, 15 (2):
  • [50] Tracking changes in cardiac output: methodological considerations for the validation of monitoring devices
    Squara, Pierre
    Cecconi, Maurizio
    Rhodes, Andrew
    Singer, Mervyn
    Chiche, Jean-Daniel
    INTENSIVE CARE MEDICINE, 2009, 35 (10) : 1801 - 1808