Cardiac output monitoring devices: an analytic review

被引:12
|
作者
Porhomayon, Jahan [1 ]
El-Solh, Ali [2 ]
Papadakos, Peter [3 ]
Nader, Nader Djalal [1 ]
机构
[1] SUNY Buffalo, Sch Med & Biomed Sci, Dept Anesthesiol, VA Western New York Healthcare Syst, Buffalo, NY 14215 USA
[2] SUNY Buffalo, Sch Med & Biomed Sci, Div Pulm, Dept Med Crit Care & Sleep Med,VA Western New Yor, Buffalo, NY 14215 USA
[3] Univ Rochester, Crit Care Med & Trauma Intens Care Unit, Div Anesthesiol Crit Care Med, Strong Mem Hosp, Rochester, NY USA
关键词
Cardiac output; FloTrac; LiDCO; Esophageal Doppler; Echocardiography; ECOM; PiCCO; Pulmonary artery catheter; PULMONARY-ARTERY CATHETER; WAVE-FORM ANALYSIS; EXTRAVASCULAR LUNG WATER; PULSE-CONTOUR ANALYSIS; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; THERMODILUTION; SYSTEM; VOLUME; MANAGEMENT; VALIDITY;
D O I
10.1007/s11739-011-0738-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate cardiac output (CO), both invasive and semi-invasive monitors are used in critical care medicine. The pulmonary artery catheter is an invasive tool to assess CO with the major criticism that the level of its invasiveness is not supported by an improvement in patients' outcomes. The interest in a lesser invasive techniques is high. Therefore, alternative techniques have been developed recently, and are used frequently in critical care medicine. Cardiac output can be monitored continuously by different devices that analyze the stroke volume and CO. The purpose of this review is to understand these new technologies and their applications and limitations.
引用
收藏
页码:163 / 171
页数:9
相关论文
共 50 条
  • [21] Cardiac output monitoring in newborns
    de Boode, Willem-Pieter
    EARLY HUMAN DEVELOPMENT, 2010, 86 (03) : 143 - 148
  • [22] Reliability of cardiac output measurements using LiDCOrapid™ and FloTrac/Vigileo™ across broad ranges of cardiac output values
    Asamoto, Masaaki
    Orii, Ryo
    Otsuji, Mikiya
    Bougaki, Masahiko
    Imai, Yousuke
    Yamada, Yoshitsugu
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (04) : 709 - 716
  • [23] Noninvasive Cardiac Output Monitors: A State-of the-Art Review
    Marik, Paul E.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (01) : 121 - 134
  • [24] Relationship Between Plethysmographic Waveform Changes and Hemodynamic Variables in Anesthetized, Mechanically Ventilated Patients Undergoing Continuous Cardiac Output Monitoring
    Thiele, Robert H.
    Colquhoun, Douglas A.
    Patrie, James
    Nie, Sarah H.
    Huffmyer, Julie L.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (06) : 1044 - 1050
  • [25] Cardiac Output Monitoring and Fluid Responsiveness
    Christos Lazaridis
    Neurocritical Care, 2012, 16 : 486 - 487
  • [26] Cardiac output monitoring: an integrative perspective
    Jamal A Alhashemi
    Maurizio Cecconi
    Christoph K Hofer
    Critical Care, 15
  • [27] Cardiac output monitoring in pediatric patients
    Nusmeier, Anneliese
    van der Hoeven, Johannes G.
    Lemson, Joris
    EXPERT REVIEW OF MEDICAL DEVICES, 2010, 7 (04) : 503 - 517
  • [28] Newer methods of cardiac output monitoring
    Mehta, Yatin
    Arora, Dheeraj
    WORLD JOURNAL OF CARDIOLOGY, 2014, 6 (09): : 1022 - 1029
  • [29] Cardiac output monitoring
    Mathews, Lailu
    Singh, Kalyan R. K.
    ANNALS OF CARDIAC ANAESTHESIA, 2008, 11 (01) : 56 - 68
  • [30] Systematic review of cardiac output measurements by echocardiography vs. thermodilution: the techniques are not interchangeable
    Wetterslev, Mik
    Moller-Sorensen, Hasse
    Johansen, Rasmus Rothmann
    Perner, Anders
    INTENSIVE CARE MEDICINE, 2016, 42 (08) : 1223 - 1233