In Vivo Release of Vancomycin from Calcium Phosphate Cement

被引:13
|
作者
Uchida, Kentaro [1 ]
Sugo, Ken [2 ]
Nakajima, Takehiko [2 ]
Nakawaki, Mitsufumi [1 ]
Takano, Shotaro [1 ]
Nagura, Naoshige [1 ]
Takaso, Masashi [1 ]
Urabe, Ken [3 ]
机构
[1] Kitasato Univ, Dept Orthoped Surg, Sch Med, Minami Ku, 1-15-1 Kitasato, Sagamihara, Kanagawa 2520375, Japan
[2] HOYA Technosurg Corp, Res & Dev Dept, 1-1-110 Tsutsujigaoka, Akishima, Tokyo 1960012, Japan
[3] Kitasato Univ, Dept Orthoped Surg, Med Ctr, 6-100 Arai, Kitamoto, Saitama 3648501, Japan
关键词
RESISTANT STAPHYLOCOCCUS-AUREUS; TOTAL KNEE ARTHROPLASTY; BONE-CEMENT; ANTIBIOTIC RELEASE; GROWTH-INHIBITION; VITRO ELUTION; POLYMETHYLMETHACRYLATE; SPACERS; GENTAMICIN; INFECTION;
D O I
10.1155/2018/4560647
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Calcium phosphate cement (CPC) has good release efficiency and has therefore been used as a drug delivery system for postoperative infection. The release profile of CPC has mainly been evaluated by in vitro studies, which are carried out by immersing test specimens in a relatively large amount of solvent. However, it remains unclear whether antibiotic-impregnated CPC has sufficient clinical effects and release in vivo. We examined the in vivo release profile of CPC impregnated with vancomycin (VCM) and compared this with that of polymethylmethacrylate (PMMA) cement. To evaluate the release profile in vitro, the test specimens were immersed in 10 mL sterile phosphate-buffered saline per gram of test specimen and incubated at 37 degrees C for 56 days in triplicate. For in vivo experiments, the test specimens were implanted between the fascia and muscle of the femur of rats. Residual VCM was extracted from the removed test specimens to determine the amount of VCM released into rat tissues. CPC released more VCM over a longer duration than PMMA in vitro. Released levels of VCM from CPC/VCM in vivo were 3.4-fold, 5.0-fold, and 8.6-fold greater on days 1, 7, and 28, respectively, than those released on the corresponding days from PMMA/VCM and were drastically greater on day 56 due to inefficient release from PMMA/VCM. The amount of VCM released from CPC and PMMA was much higher than the minimum inhibitory concentration (1.56 mu g) and lower than the detection limit, respectively. Our findings suggest that CPC is a suitable material for releasing antibiotics for local action against established postoperative infection.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Long-term antibacterial activity of vancomycin from calcium phosphate cement in vivo
    Mukai, Manabu
    Uchida, Kentaro
    Sugo, Ken
    Nakasu, Masanori
    Nakajima, Takehiko
    Takata, Ken
    Takaso, Masashi
    Urabe, Ken
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2022, 33 (01) : 41 - 50
  • [2] In vitro elution of vancomycin from calcium phosphate cement
    Sasaki, T
    Ishibashi, Y
    Katano, H
    Nagumo, A
    Toh, S
    JOURNAL OF ARTHROPLASTY, 2005, 20 (08): : 1055 - 1059
  • [3] The effect of porosity on drug release kinetics from vancomycin microsphere/calcium phosphate cement composites
    Schnieders, Julia
    Gbureck, Uwe
    Vorndran, Elke
    Schossig, Michael
    Kissel, Thomas
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2011, 99B (02) : 391 - 398
  • [4] Optimizing Vancomycin Release from Calcium Phosphate-Based Cement by Carboxymethyl Cellulose for Prevention of Osteomyelitis
    Lin, Boren
    Caldwell, Ciara
    Bhaduri, Sarit
    Goel, Vijay
    Agarwal, Anand
    SURGICAL INFECTIONS, 2017, 18 (02) : 221 - 222
  • [5] In vivo release of the antimicrobial peptide hLF1-11 from calcium phosphate cement
    Stallmann, Hein P.
    de Roo, Ronald
    Faber, Chris
    Amerongen, Arie V. Nieuw
    Wuisman, Paul I. J. M.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (04) : 531 - 538
  • [6] In vitro comparison of elution characteristics of vancomycin from calcium phosphate cement and polymethylmethacrylate
    Urabe, Ken
    Naruse, Kouji
    Hattori, Hideki
    Hirano, Masahiro
    Uchida, Kentaroo
    Onuma, Kenji
    Park, Hwang Jung
    Itoman, Moritoshi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2009, 14 (06) : 784 - 793
  • [7] Release of antibiotics from macroporous injectable calcium phosphate cement
    McNally, Alex
    Sly, Kurt
    Lin, Steve
    Bourges, Xavier
    Daculsi, Guy
    BIOCERAMICS, VOL 20, PTS 1 AND 2, 2008, 361-363 : 359 - +
  • [8] Controlled release of gentamicin from calcium phosphate/alginate bone cement
    Chen, Chan-Hen David
    Chen, Chun-Cheng
    Shie, Ming-You
    Huang, Chiao-Hui
    Ding, Shinn-Jyh
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (02): : 334 - 341
  • [9] Sustained release of simvastatin from premixed injectable calcium phosphate cement
    Montazerolghaem, Maryam
    Engqvist, Hakan
    Ott, Marjam Karlsson
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2014, 102 (02) : 340 - 347
  • [10] The effect of porosity on drug release kinetics from vancomycin microsphere/calcium phosphate cement composites (vol 99, pg 391, 2011)
    Schnieders, Julia
    Gbureck, Uwe
    Vorndran, Elke
    Schossig, Michael
    Kissel, Thomas
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2012, 100B (03) : 890 - 890