Direct pulp capping with a dentin bonding system in human teeth: A clinical and histological evaluation

被引:46
作者
Silva, G. A. B.
Lanza, L. D.
Lopes-Junior, N.
Moreira, A.
Alves, J. B.
机构
[1] Inst Biol Sci, Dept Morphol, Belo Horizonte, MG, Brazil
[2] Inst Biol Sci, Fac Dent, Dept Restorat Odontol, Belo Horizonte, MG, Brazil
[3] Inst Biol Sci, Dept Morphol, Belo Horizonte, MG, Brazil
[4] Univ Uberaba, Inst Biol Sci, Uberaba, MG, Brazil
关键词
D O I
10.2341/05-65
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the pulpal response in human dental pulp to direct pulp capping with the Single Bond Adhesive System (SBAS) after 10% or 37% phosphoric acid etching and after capping with Calcium Hydroxide (CH). The degree of bleeding and hemostasis conditions was considered during the adhesive technique. The pulps of 78 sound premolars were capped with SBAS after 37% phosphoric acid etching (Group I) or 10% phosphoric acid etching (Group II) and CH (Group III-control). The cavities were restored with a resin composite (Charisma). After 1, 3, 7 and 30 days, the teeth were extracted and processed for light microscopical examination (H/E, AgNOR silver stain and Brown-Brenn). The patients were followed for postoperative symptomatology evaluation. Clinical results showed the possibility of hemostasis with saline solution only. There was no statistical difference between bleeding generated by 10% and 37% acid solutions. In some cases, contact of the pulp tissue with SASB started the bleeding process, thus damaging the adhesive technique. The histological response was similar in Groups I and II, without signs of cellular differentiation and dentin neoformation up to 30 days. Bacteria were not observed in any specimens. In the control group (CH) at day 7, the pulps exhibited cells with high synthetic activity (Ag-NOR-positive) underneath the area of coagulation necrosis. Dentin bridging was observed at the thirtieth day. The postoperative period was asymptomatic for all groups. In conclusion, SBAS should be avoided for vital pulp therapy, while CH remains the capping agent of choice for mechanically exposed human dental pulp.
引用
收藏
页码:297 / 307
页数:11
相关论文
共 40 条
[1]   Vasorelaxant effect of resin-based, single-bottle dentin bonding systems [J].
Abebe, W ;
Pashley, DH ;
Rueggeberg, FA .
JOURNAL OF ENDODONTICS, 2005, 31 (03) :194-197
[2]   Adverse effects of human pulps after direct pulp capping with the different components from a total-etch, three-step adhesive system [J].
Accorinte, MDR ;
Loguercio, AD ;
Reis, A ;
Muench, A ;
de Araújo, VC .
DENTAL MATERIALS, 2005, 21 (07) :599-607
[3]  
Accorinte MLR, 2005, OPER DENT, V30, P147
[4]  
Akimoto N, 1998, QUINTESSENCE INT, V29, P177
[5]   PULPAL REACTION TO COMPOSITE RESIN RESTORATIONS [J].
BRANNSTROM, M ;
NYBORG, H .
JOURNAL OF PROSTHETIC DENTISTRY, 1972, 27 (02) :181-+
[6]  
Costa CAD, 2000, DENT MATER, V16, P188
[7]  
Costa CAD, 2001, DENT MATER, V17, P230
[8]   Biocompatibility of resin-based materials used as pulp-capping agents [J].
Costa, CAS ;
Oliveira, MF ;
Giro, EMA ;
Hebling, J .
INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (12) :831-839
[9]   BIOCOMPATIBILITY OF SURFACE-SEALED DENTAL MATERIALS AGAINST EXPOSED PULPS [J].
COX, CF ;
KEALL, CL ;
KEALL, HJ ;
OSTRO, E ;
BERGENHOLTZ, G .
JOURNAL OF PROSTHETIC DENTISTRY, 1987, 57 (01) :1-8
[10]  
Cox CF, 1998, AM J DENT, V11, pS55