The accuracy of an external frame using ISB recommended rotation sequence to define shoulder joint angle

被引:3
作者
Xu, Xu [1 ]
McGorry, Raymond W. [1 ]
Lin, Jia-hua [1 ]
机构
[1] Liberty Mutual Res Inst Safety, Hopkinton, MA 01748 USA
关键词
Shoulder kinematics; Plane of elevation; Elevation angle; Axial rotation; MOTION; RELIABILITY; MARKERS;
D O I
10.1016/j.gaitpost.2013.08.032
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
When investigating shoulder kinematics, it may be necessary to limit shoulder joint angles at a specific level. Previous studies used external frames or external surfaces to assist the participant to reach the shoulder joint angles of interest. The accuracy of these methods, however, has not yet been investigated. In the current study, an external frame was designed to assist in maintaining specific shoulder postures in a wide range. The three degrees of freedom of rotation of the proposed frame were designed to be consistent with the description of shoulder joint angles recommended by the International Society of Biomechanics. Six participants used this frame to perform 118 different shoulder postures. The reference joint angles measured by a motion tracking system were compared with the frame-defined angles. The angle differences among all the participants ranged from 12.7 degrees to 85.6 degrees, with an average of 32.2 degrees (SD 15.1 degrees) across all postures. For the postures with elevation angles on or below horizontal, the average angle difference was 23.7 degrees (SD 8.5 degrees). Findings suggest that errors exist when using an external frame to assist in reaching specific shoulder postures. Error is minimized at elevation angles close to -30 degrees, and the performance is poor for extreme shoulder postures. (C) 2013 The Authors. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:662 / 668
页数:7
相关论文
共 16 条
  • [1] Effects of posture, movement and hand load on shoulder muscle activity
    Antony, Nicholas T.
    Keir, Peter J.
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2010, 20 (02) : 191 - 198
  • [2] Accuracy and reliability of three methods of recording scapular motion using reflective skin markers
    Brochard, S.
    Lempereur, M.
    Remy-Neris, O.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H1) : 100 - 105
  • [3] The role of the scapulo-thoracic and gleno-humeral joints in upper-limb motion in children with hemiplegic cerebral palsy
    Brochard, Sylvain
    Lempereur, Mathieu
    Mao, Linda
    Remy-Neris, Olivier
    [J]. CLINICAL BIOMECHANICS, 2012, 27 (07) : 652 - 660
  • [4] Double calibration: An accurate, reliable and easy-to-use method for 3D scapular motion analysis
    Brochard, Sylvain
    Lempereur, Mathieu
    Remy-Neris, Olivier
    [J]. JOURNAL OF BIOMECHANICS, 2011, 44 (04) : 751 - 754
  • [5] Craig J.J., 2008, Introduction To Robotics: Mechanics And Control
  • [6] TOWARDS A MODEL FOR FORCE PREDICTIONS IN THE HUMAN SHOULDER
    KARLSSON, D
    PETERSON, B
    [J]. JOURNAL OF BIOMECHANICS, 1992, 25 (02) : 189 - 199
  • [7] An alternative definition of the scapular coordinate system for use with RSA
    Kedgley, Angela E.
    Dunning, Cynthia E.
    [J]. JOURNAL OF BIOMECHANICS, 2010, 43 (08) : 1527 - 1531
  • [8] Kuipers J., 2002, Quaternions and Rotation Sequences: A Primer With Applications to Orbits, Aerospace and Virtual Reality
  • [9] Dynamic tracking of the scapula using skin-mounted markers
    Lovern, B.
    Stroud, L. A.
    Evans, R. O.
    Evans, S. L.
    Holt, C. A.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H7) : 823 - 831
  • [10] Requirements for upper extremity motions during activities of daily living
    Magermans, DJ
    Chadwick, EKJ
    Veeger, HEJ
    van der Helm, FCT
    [J]. CLINICAL BIOMECHANICS, 2005, 20 (06) : 591 - 599