Method Validation of 16 Types of Structural Amino Acids using an Automated Amino Acid Analyzer

被引:31
|
作者
Shim, You-Shin [1 ]
Yoon, Won-Jin [1 ,2 ]
Ha, Jaeho [1 ]
Seo, Dongwon [1 ]
Lee, Kwang-Won [2 ]
Lee, Woo-Young [3 ]
Kwon, Kwang-Il [4 ]
Kang, Tae-Seok [5 ]
Lee, Jin-Ha [5 ]
Kim, Hyun-Jeong [6 ]
Kwak, Hae-Jung [6 ]
Lee, Sam-Pin [6 ]
Kim, So-Jung [7 ]
Yun, Won-Kap [7 ]
Lee, Junsoo [8 ]
Hwang, Jin-Bong [1 ]
机构
[1] Korea Food Res Inst, Food Anal Ctr, Gyeonggi 463746, South Korea
[2] Korea Univ, Coll Life Sci & Biotechnol, Seoul 136701, South Korea
[3] Nutr Safety Policy Div, Food Nutr & Dietary Safety Bur, Minist Food & Drug safety, Chungbuk 363700, South Korea
[4] Dietary Life Safety Div, Food Nutr & Dietary Safety Bur, Minist Food & Drug safety, Chungbuk 363700, South Korea
[5] Natl Inst Food & Drug safety Evaluat, Food safety Evaluat Dept, Chungbuk 363700, South Korea
[6] Keimyung Univ, Ctr Tradit Microorganism Resource, Taegu 704701, South Korea
[7] Gyeongbuk Inst Marine Bioind, Gyeongbuk 767813, South Korea
[8] Chungbuk Natl Univ, Dept Food Sci & Technol, Chungbuk 361763, South Korea
关键词
amino acids; automated amino acid analyzer; analytical method; validation; post column reaction; CHROMATOGRAPHY-MASS-SPECTROMETRY; PRECOLUMN DERIVATIZATION; PERFORMANCE; DERIVATIVES; MS/MS; FLUIDS; SERUM;
D O I
10.1007/s10068-013-0252-0
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
An analytical method for the simultaneous determination of 16 types of structural amino acids in infant formula using an automated amino acid analyzer was validated through tests of precision, accuracy and linearity. The automated analysis of the amino acids was performed on an ion-exchange packed column with a visible detector. The certificated reference material (CRM) 1546 from NIST was used as the test sample to determine the precision and accuracy of the analytical method. The regression analyses revealed good correlations [correlation coefficient (r(2))] that were greater than 0.99. The recovery values of the amino acids were ranged from 87.18 to 118.08%. The limits of detection and limits of quantification were less than 0.059 mg/100 g and less than 0.198 mg/100 g, respectively. The infra- and inter-day precisions were less than 14.62% in the CRM sample.
引用
收藏
页码:1567 / 1571
页数:5
相关论文
共 50 条
  • [1] Method validation of 16 types of structural amino acids using an automated amino acid analyzer
    You-Shin Shim
    Won-Jin Yoon
    Jaeho Ha
    Dongwon Seo
    Kwang-Won Lee
    Woo-Young Lee
    Kwang-Il Kwon
    Tae-Seok Kang
    Jin-Ha Lee
    Hyun-Jeong Kim
    Hae-Jung Kwak
    Sam-Pin Lee
    So-Jung Kim
    Won-Kap Yun
    Junsoo Lee
    Jin-Bong Hwang
    Food Science and Biotechnology, 2013, 22 : 1567 - 1571
  • [2] A METHOD FOR IMPROVED RESOLUTION OF BASIC AMINO ACIDS ON AUTOMATIC AMINO ACID ANALYZER
    KOMINZ, DR
    JOURNAL OF CHROMATOGRAPHY, 1962, 9 (02): : 253 - &
  • [3] MODIFIED METHOD FOR SEPARATION OF BASIC AMINO ACIDS ON AUTOMATIC AMINO ACID ANALYZER
    KIRKPATRICK, CH
    ANDERSON, RA
    JOURNAL OF CHROMATOGRAPHY, 1964, 14 (02): : 295 - &
  • [4] AN AUTOMATED AMINO-ACID ANALYZER
    DILLEY, KJ
    INTERNATIONAL LABORATORY, 1980, 10 (04): : 79 - &
  • [5] AN AUTOMATED AMINO-ACID ANALYZER
    DILLEY, KJ
    AMERICAN LABORATORY, 1980, 12 (05) : 113 - &
  • [6] The first automated amino acid analyzer
    Sharrer, Terry
    SCIENTIST, 2006, 20 (09): : 92 - 92
  • [7] AUTOMATED CHROMATOGRAPHY OF AROMATIC ACIDS, ALDEHYDES AND ALCOHOLS WITH AN AMINO ACID ANALYZER
    LANGE, HW
    HEMPEL, K
    JOURNAL OF CHROMATOGRAPHY, 1971, 59 (01): : 53 - &
  • [8] MODIFIED METHOD OF ISOLATING FREE AMINO-ACIDS FOR DETERMINATION ON AN AMINO-ACID ANALYZER
    KALINKINA, LG
    NAZARENKO, LV
    GORDEEVA, EE
    SOVIET PLANT PHYSIOLOGY, 1990, 37 (03): : 471 - 474
  • [9] Determination of structural amino acid contents in bamboo shoot, tomato and corn undergoing different cooking methods using automated amino acid analyzer
    Seo, Dongwon
    Yoon, Won-Jin
    Lee, Hyunjun
    Hwang, Jinbong
    Yang, Mi-Ok
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [10] DETERMINATION OF LYSINE ON AUTOMATED AMINO ACID ANALYZER BY A TRIPLICATE-SAMPLE METHOD
    VILLEGAS, E
    MCDONALD, CE
    GILLES, KA
    CEREAL CHEMISTRY, 1968, 45 (05) : 432 - &