Reliability of oesophageal pH recording for the detection of gastro-oesophageal reflux

被引:10
|
作者
Aanen, Marissa C. [1 ]
Bredenoord, Albert J. [2 ]
Samsom, Melvin
Smout, Andre J. P. M.
机构
[1] Univ Med Ctr Utrecht, Dept Gastroenterol & Hepatol, Gastrointestinal Res Unit, NL-3508 GA Utrecht, Netherlands
[2] St Antonius Hosp, Dept Gastroenterol, Nieuwegein, Netherlands
关键词
Gastro-oesophageal reflux; impedance; pH drops; pH monitoring;
D O I
10.1080/00365520802308003
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objective. Despite the new gold standard oesophageal impedance monitoring, pH monitoring is still used frequently for detection of gastro-oesophageal reflux (GOR). Besides drops in pH from above to below pH4, drops of 1 unit are also used as a marker for GOR. In this study the objective was to investigate the accuracy of drops in pH for detection of GOR, using impedance monitoring as the gold standard. Material and methods. Nineteen GORD patients (9 M, 5511 years) underwent combined 24-h pH-impedance recording off acid-suppressive therapy. All drops in pH 0.5 pH units, with a duration 4 s, reaching the nadir pH within 5 s after onset were included. Reflux events detected with impedance monitoring were taken as the reference. Results. In total, 2221 drops in pH were found; 47% were acid (nadir pH 4), 47% weakly acidic (nadir pH between pH7 and 4) and 5% were superimposed (pH drop starting below pH4). The sensitivities of acid, weakly acidic and superimposed pH drops 1 were 91%, 28%, 24%, respectively, and the percentages of false-positive reflux episodes were 20, 56 and 54, respectively. Acid reflux with a cut-off 0.5 and 3.3 had a moderate-to-good sensitivity (94-70%) and low false-positive percentages (23-13%). In contrast, weakly acidic and superimposed reflux showed greater false-positive than true-positive percentages for all cut-off values. Conclusions. Compared to impedance monitoring, detection of reflux with pH monitoring is clearly inferior. When drops in pH 1 are used irrespective of nadir pH as an indicator of reflux episodes, the number of reflux episodes is overestimated. Decreases from above to below 4 with cut-offs between 0.5 and 3.3 are the most indicative of true reflux episodes.
引用
收藏
页码:1442 / 1447
页数:6
相关论文
共 50 条
  • [1] PROLONGED PH RECORDING IN STUDY OF GASTRO-OESOPHAGEAL REFLUX
    SPENCER, J
    BRITISH JOURNAL OF SURGERY, 1969, 56 (12) : 912 - &
  • [3] Gastro-oesophageal reflux
    Patiño, JV
    Maoño, MS
    REVISTA CLINICA ESPANOLA, 1999, 199 (07): : 415 - 417
  • [4] Gastro-oesophageal reflux
    Karthik, SV
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 2004, 97 (01) : 49 - 49
  • [5] Gastro-oesophageal reflux disease: oesophageal impedance versus pH monitoring
    Vandenplas, Yvan
    Salvatore, Silvia
    Devreker, Thierry
    Hauser, Bruno
    ACTA PAEDIATRICA, 2007, 96 (07) : 956 - 962
  • [6] The temporal relationship between oesophageal bile reflux and pH in gastro-oesophageal reflux disease
    Marshall, REK
    Anggiansah, A
    Owen, WA
    Owen, WJ
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 1998, 10 (05) : 385 - 392
  • [7] Oesophageal disorders and gastro-oesophageal reflux disease
    Tytgat, GNJ
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 1999, 11 (01) : 9 - 11
  • [8] New techniques for the detection of gastro-oesophageal reflux
    Tack, J
    Sifrim, D
    DIGESTIVE AND LIVER DISEASE, 2000, 32 : S245 - S248
  • [9] Detection of gastro-oesophageal reflux in the neonatal unit
    Rossor, Thomas
    Lingam, Ingran
    Douiri, Abdel
    Bhat, Ravindra
    Greenough, Anne
    ACTA PAEDIATRICA, 2018, 107 (09) : 1535 - 1540
  • [10] Gastro-oesophageal reflux in children
    Taminiau, JAJM
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1997, 32 : 18 - 20