Numerical investigation on radiative and evaporative characteristics of a liquid droplet radiator through Monte-Carlo method

被引:3
作者
Yang, Linyi [1 ]
Wang, Chenglong [1 ]
Qin, Hao [1 ]
Zhang, Dalin [1 ]
Tian, Wenxi [1 ]
Su, G. H. [1 ]
Qiu, Suizheng [1 ]
机构
[1] Xi An Jiao Tong Univ, Dept Nucl Sci & Technol, Shaanxi Key Lab Adv Nucl Energy & Technol, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Megawatt-scale space power systems; Liquid droplet radiator; Radiative heat transfer; Evaporative loss; Monte-Carlo method; Numerical simulation; HEAT REJECTION;
D O I
10.1016/j.applthermaleng.2022.119077
中图分类号
O414.1 [热力学];
学科分类号
摘要
The liquid droplet radiator (LDR), a frameless heat dissipation device, is regarded as a preferred heat control solution for megawatt-scale space power systems. Accurate calculation of evaporation loss in the droplet layer is important for LDR systems since it determines the operating life of the LDR. In the present work, a novel model based on the Monte-Carlo Method (MCM) was developed to calculate the evaporation loss of the droplet layer. Compared to previous work in the literature, this model considers the evaporation loss of the droplet layer in the thickness and length directions. The radiative heat transfer characteristics of the droplet layer are also studied. The effects of optical thickness, operation temperature, and flight time on the droplet layer's heat transfer and evaporation processes were obtained and analyzed. The calculation results show that the temperature difference between the center and the edge of the droplet layer is larger than 65 K when the optical thickness is greater than 5. The heat dissipation power no longer varies significantly when the optical thickness of the droplet layer is greater than 6. The region with a negative specific evaporation loss rate accounts for 55.2 %, 58.2 %, and 0 for the whole droplet layer with optical thicknesses of 10, 5, and 0.2, respectively. The main evaporative loss comes from the beginning 5 m of the droplet layer. This paper may provide favorable reference to the design and optimization of the LDR systems.
引用
收藏
页数:16
相关论文
共 29 条
[1]   Development and testing of the re-deployable radiator for deep space explorer [J].
Akizuki, Yuki ;
Nagano, Hosei ;
Kinjo, Tomihiro ;
Sawada, Kenichiro ;
Ogawa, Hiroyuki ;
Takashima, Takeshi ;
Nishiyama, Kazutaka ;
Toyota, Hiroyuki ;
Watanabe, Kazuki ;
Kuratomi, Takeshi .
APPLIED THERMAL ENGINEERING, 2020, 165
[2]   Testing and analysis of a morphing radiator concept for thermal control of crewed space vehicles [J].
Bertagne, Christopher L. ;
Cognata, Thomas J. ;
Sheth, Rubik B. ;
Dinsmore, Craig E. ;
Hartl, Darren J. .
APPLIED THERMAL ENGINEERING, 2017, 124 :986-1002
[3]  
Buch R R, 1985, Organosiloxane working fluids for the liquid droplet radiator
[4]  
Chen P, 1987, SCI FDN VACUUM TECHN
[5]  
[代智文 Dai Zhiwen], 2019, [原子能科学技术, Atomic Energy Science and Technology], V53, P1296
[6]  
Howell J. R., 2020, THERMAL RAD HEAT TRA
[7]  
Li Q., 2010, Research of heat transfer in liquid droplet radiation refrigerator for space station
[8]  
Ma Y., 2010, NUMERICAL STUDY RAD
[9]   LIQUID DROPLET RADIATORS FOR HEAT REJECTION IN SPACE [J].
MATTICK, AT ;
HERTZBERG, A .
JOURNAL OF ENERGY, 1981, 5 (06) :387-393
[10]   Energy allocation optimization of the gas-cooled space nuclear reactor [J].
Qin, Hao ;
Wang, Chenglong ;
Tian, Wenxi ;
Qiu, Suizheng ;
Su, Guanghui .
APPLIED THERMAL ENGINEERING, 2021, 196