Single cell detection with micromechanical oscillators

被引:350
作者
Ilic, B
Czaplewski, D
Zalalutdinov, M
Craighead, HG
Neuzil, P
Campagnolo, C
Batt, C
机构
[1] Cornell Univ, Sch Appl & Engn Phys, Ithaca, NY 14853 USA
[2] Cornell Univ, Nanobiotechnol Ctr, Ithaca, NY 14853 USA
[3] Inst Microelect, Singapore 117685, Singapore
[4] Cornell Univ, Field Microbiol, Ithaca, NY 14853 USA
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B | 2001年 / 19卷 / 06期
关键词
D O I
10.1116/1.1421572
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The ability to detect small amounts of materials, especially pathogenic bacteria, is important for medical diagnostics and for monitoring the food supply. Engineered micro- and nanomechanical systems can serve as multifunctional, highly sensitive, immunospecific biological detectors. We present a resonant frequency-based mass sensor, comprised of low-stress silicon nitride cantilever beams for the detection of Escherichia coli (E. coli) -cell- antibody binding events with detection sensitivity down to a single cell. The binding events involved the interaction between anti-E. coli O157:H7 antibodies immobilized on a cantilever beam and the O157 antigen present on the surface of pathogenic E. coli O157:H7. Additional mass loading from the specific binding of the E. coli cells was detected by measuring a resonant frequency shift of the micromechanical oscillator. In air, where considerable damping occurs, our device mass sensitivities for a 15 mum and 25 mum long beam were 1.1 Hz/fg and 7.1 Hz/fg, respectively. In both cases, utilizing thermal and ambient noise as a driving mechanism, the sensor was highly effective in detecting immobilized anti-E. coli antibody monolayer assemblies, as well as single E. coli cells. Our results suggest that tailoring of oscillator dimensions is a feasible approach for sensitivity enhancement of resonant mass sensors. (C) 2001 American Vacuum Society.
引用
收藏
页码:2825 / 2828
页数:4
相关论文
共 22 条
  • [1] Biosensor based on force microscope technology
    Baselt, DR
    Lee, GU
    Colton, RJ
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (02): : 789 - 793
  • [2] ATOMIC FORCE MICROSCOPE
    BINNIG, G
    QUATE, CF
    GERBER, C
    [J]. PHYSICAL REVIEW LETTERS, 1986, 56 (09) : 930 - 933
  • [3] Measurement of mechanical resonance and losses in nanometer scale silicon wires
    Carr, DW
    Evoy, S
    Sekaric, L
    Craighead, HG
    Parpia, JM
    [J]. APPLIED PHYSICS LETTERS, 1999, 75 (07) : 920 - 922
  • [4] Translating biomolecular recognition into nanomechanics
    Fritz, J
    Baller, MK
    Lang, HP
    Rothuizen, H
    Vettiger, P
    Meyer, E
    Güntherodt, HJ
    Gerber, C
    Gimzewski, JK
    [J]. SCIENCE, 2000, 288 (5464) : 316 - 318
  • [5] OBSERVATION OF A CHEMICAL-REACTION USING A MICROMECHANICAL SENSOR
    GIMZEWSKI, JK
    GERBER, C
    MEYER, E
    SCHLITTLER, RR
    [J]. CHEMICAL PHYSICS LETTERS, 1994, 217 (5-6) : 589 - 594
  • [6] Atomic force microscopy with patterned cantilevers and tip arrays: Force measurements with chemical arrays
    Green, JBD
    Lee, GU
    [J]. LANGMUIR, 2000, 16 (08) : 4009 - 4015
  • [7] Detection and localization of individual antibody-antigen recognition events by atomic force microscopy
    Hinterdorfer, P
    Baumgartner, W
    Gruber, HJ
    Schilcher, K
    Schindler, H
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (08) : 3477 - 3481
  • [8] Mechanical resonant immunospecific biological detector
    Ilic, B
    Czaplewski, D
    Craighead, HG
    Neuzil, P
    Campagnolo, C
    Batt, C
    [J]. APPLIED PHYSICS LETTERS, 2000, 77 (03) : 450 - 452
  • [9] PIEZOELECTRIC SORPTION DETECTOR
    KING, WH
    [J]. ANALYTICAL CHEMISTRY, 1964, 36 (09) : 1735 - &
  • [10] PIEZOELECTRIC DEVICES FOR MASS AND CHEMICAL MEASUREMENTS - AN UPDATE - A REVIEW
    MCCALLUM, JJ
    [J]. ANALYST, 1989, 114 (10) : 1173 - 1189