Single cell detection with micromechanical oscillators

被引:352
作者
Ilic, B
Czaplewski, D
Zalalutdinov, M
Craighead, HG
Neuzil, P
Campagnolo, C
Batt, C
机构
[1] Cornell Univ, Sch Appl & Engn Phys, Ithaca, NY 14853 USA
[2] Cornell Univ, Nanobiotechnol Ctr, Ithaca, NY 14853 USA
[3] Inst Microelect, Singapore 117685, Singapore
[4] Cornell Univ, Field Microbiol, Ithaca, NY 14853 USA
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B | 2001年 / 19卷 / 06期
关键词
D O I
10.1116/1.1421572
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The ability to detect small amounts of materials, especially pathogenic bacteria, is important for medical diagnostics and for monitoring the food supply. Engineered micro- and nanomechanical systems can serve as multifunctional, highly sensitive, immunospecific biological detectors. We present a resonant frequency-based mass sensor, comprised of low-stress silicon nitride cantilever beams for the detection of Escherichia coli (E. coli) -cell- antibody binding events with detection sensitivity down to a single cell. The binding events involved the interaction between anti-E. coli O157:H7 antibodies immobilized on a cantilever beam and the O157 antigen present on the surface of pathogenic E. coli O157:H7. Additional mass loading from the specific binding of the E. coli cells was detected by measuring a resonant frequency shift of the micromechanical oscillator. In air, where considerable damping occurs, our device mass sensitivities for a 15 mum and 25 mum long beam were 1.1 Hz/fg and 7.1 Hz/fg, respectively. In both cases, utilizing thermal and ambient noise as a driving mechanism, the sensor was highly effective in detecting immobilized anti-E. coli antibody monolayer assemblies, as well as single E. coli cells. Our results suggest that tailoring of oscillator dimensions is a feasible approach for sensitivity enhancement of resonant mass sensors. (C) 2001 American Vacuum Society.
引用
收藏
页码:2825 / 2828
页数:4
相关论文
共 22 条
[1]   Biosensor based on force microscope technology [J].
Baselt, DR ;
Lee, GU ;
Colton, RJ .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (02) :789-793
[2]   ATOMIC FORCE MICROSCOPE [J].
BINNIG, G ;
QUATE, CF ;
GERBER, C .
PHYSICAL REVIEW LETTERS, 1986, 56 (09) :930-933
[3]   Measurement of mechanical resonance and losses in nanometer scale silicon wires [J].
Carr, DW ;
Evoy, S ;
Sekaric, L ;
Craighead, HG ;
Parpia, JM .
APPLIED PHYSICS LETTERS, 1999, 75 (07) :920-922
[4]   Translating biomolecular recognition into nanomechanics [J].
Fritz, J ;
Baller, MK ;
Lang, HP ;
Rothuizen, H ;
Vettiger, P ;
Meyer, E ;
Güntherodt, HJ ;
Gerber, C ;
Gimzewski, JK .
SCIENCE, 2000, 288 (5464) :316-318
[5]   OBSERVATION OF A CHEMICAL-REACTION USING A MICROMECHANICAL SENSOR [J].
GIMZEWSKI, JK ;
GERBER, C ;
MEYER, E ;
SCHLITTLER, RR .
CHEMICAL PHYSICS LETTERS, 1994, 217 (5-6) :589-594
[6]   Atomic force microscopy with patterned cantilevers and tip arrays: Force measurements with chemical arrays [J].
Green, JBD ;
Lee, GU .
LANGMUIR, 2000, 16 (08) :4009-4015
[7]   Detection and localization of individual antibody-antigen recognition events by atomic force microscopy [J].
Hinterdorfer, P ;
Baumgartner, W ;
Gruber, HJ ;
Schilcher, K ;
Schindler, H .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (08) :3477-3481
[8]   Mechanical resonant immunospecific biological detector [J].
Ilic, B ;
Czaplewski, D ;
Craighead, HG ;
Neuzil, P ;
Campagnolo, C ;
Batt, C .
APPLIED PHYSICS LETTERS, 2000, 77 (03) :450-452
[9]   PIEZOELECTRIC SORPTION DETECTOR [J].
KING, WH .
ANALYTICAL CHEMISTRY, 1964, 36 (09) :1735-&
[10]   PIEZOELECTRIC DEVICES FOR MASS AND CHEMICAL MEASUREMENTS - AN UPDATE - A REVIEW [J].
MCCALLUM, JJ .
ANALYST, 1989, 114 (10) :1173-1189