Evaluation of gel electrophoresis conditions for the separation of metal-tagged proteins with subsequent laser ablation ICP-MS detection

被引:52
作者
Raab, Andrea [1 ]
Ploselli, Barbara [2 ]
Munro, Caroline [2 ]
Thomas-Oates, Jane [2 ]
Feldmann, Joerg [1 ]
机构
[1] Univ Aberdeen, Coll Phys Sci, Dept Chem, Aberdeen AB24 3UE, Scotland
[2] Univ York, Dept Chem, York YO10 5DD, N Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
Gel electrophoresis; Laser ablation ICP-MS; Metalloprotein; PLASMA-MASS SPECTROMETRY; MALDI-FTICR-MS; SELENIUM-CONTAINING PROTEINS; ISOTOPE-DILUTION ANALYSIS; HUMAN BRAIN PROTEINS; SUPEROXIDE-DISMUTASE; BINDING PROTEINS; ENRICHED TRACERS; SERUM-PROTEINS; SPECIATION;
D O I
10.1002/elps.200800264
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Although laser ablation (LA)-ICP-MS has been reported for the determination of metalloproteins separated by gel electrophoretic techniques (GE), systematic studies that define the conditions essential for successful measurements are still scarce. In this paper we present the results of our studies of basic conditions for the effective application of GE-LA-ICP-MS for the separation of metal-binding proteins, focusing on their stability during GE and post-separation gel treatment. The stability of metal-protein complexes (haemoglobin, myoglobin, superoxide dismutase, carbonic anhydrase, transferrin, albumin, cytochrome c) during GE is dependent on the nature of the metal-protein interaction and the principle of separation, We have observed that non-denaturing GE is a suitable separation technique for most metal-protein complexes (e.g. Zn in carbonic anhydrase and Fe in Tf and myoglobin were quantitatively recovered in a spiked liver cytosol), whereas separation by denaturing GE strongly impaired the stability of the complexes. Equally important is the post-separation treatment of the gel to enable successful detection of the metal. LA-ICP-MS requires drying of the gel without loss of protein-bound metal or cracking of the gel. This was successfully achieved using glycerol followed by heating. We demonstrate that staining of the gel prior to LA-ICP-MS using silver or Coomassie blue is not recommended, since most protein-bound metal is lost during the staining procedure. Furthermore it has been shown that only line scanning with a speed of less than 30 mu m/s can reliably distinguish between lines 1 mm apart, while raster spot analysis carries the risk of misinterpretation due to contamination in/on inhomogeneous gels.
引用
收藏
页码:303 / 314
页数:12
相关论文
共 40 条
  • [1] Inductively coupled plasma mass spectrometry to identify protein drug targets from whole cell systems
    Allardyce, CS
    Dyson, PJ
    Abou-Shakra, FR
    Birtwistle, H
    Coffey, J
    [J]. CHEMICAL COMMUNICATIONS, 2001, (24) : 2708 - 2709
  • [2] On-line coupling of gel electrophoresis (GE) and inductively coupled plasma-mass spectrometry (ICP-MS) for the detection of Fe in metalloproteins
    Anorbe, Marta Garijo
    Messerschmidt, Rgen
    Feldmann, Ingo
    Jakubowski, Norbert
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (08) : 917 - 924
  • [3] Biosynthesis, purification and analysis of selenomethionyl calmodulin by gel electrophoresis-laser ablation-ICP-MS and capillary HPLC-ICP-MS peptide mapping following in-gel tryptic digestion
    Ballihaut, G
    Tastet, L
    Pécheyran, C
    Bouyssiere, B
    Donard, O
    Grimaud, R
    Lobinski, R
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (06) : 493 - 499
  • [4] Sensitive detection of selenoproteins in gel electrophoresis by high repetition rate femtosecond laser ablation. inductively coupled plasma mass spectrometry
    Ballihaut, Guillaume
    Claverie, Fanny
    Pecheyran, Christophe
    Mounicou, Sandra
    Grimaud, Regis
    Lobinski, Ryszard
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (17) : 6874 - 6880
  • [5] Multimode detection (LA-ICP-MS, MALDI-MS and nanoHPLC-ESI-MS2) in 1D and 2D gel electrophoresis for selenium-containing proteins
    Ballihaut, Guillaume
    Pecheyran, Christophe
    Mounicou, Sandra
    Preud'homme, Hugues
    Grimaud, Regis
    Lobinski, Ryszard
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (03) : 183 - 190
  • [6] Study of formation of Cu- and Zn-containing tau protein using isotopically-enriched tracers by LA-ICP-MS and MALDI-FTICR-MS
    Becker, J. Susanne
    Zoriy, Miroslav
    Przybylski, Michael
    Becker, J. Sabine
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (01) : 63 - 68
  • [7] Determination of phosphorus-, copper-, and zinc-containing human brain proteins by LA-ICPMS and MALDI-FTICR-MS
    Becker, JS
    Zoriy, M
    Becker, JS
    Pickhardt, C
    Damoc, E
    Juhacz, G
    Palkovits, M
    Przybylski, M
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (18) : 5851 - 5860
  • [8] Investigation of Cu-, Zn- and Fe-containing human brain proteins using isotopic-enriched tracers by LA-ICP-MS and MALDI-FT-ICR-MS
    Becker, JS
    Zoriy, M
    Pickhardt, C
    Przybylski, M
    Becker, JS
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 242 (2-3) : 135 - 144
  • [9] In-gel screening of phosphorus and copper, zinc and iron in proteins of yeast mitochondria by LA-ICP-MS and identification of phosphorylated protein structures by MALDI-FT-ICR-MS after separation with two-dimensional gel electrophoresis
    Becker, JS
    Zoriy, M
    Krause-Buchholz, U
    Becker, JS
    Pickhardt, C
    Przybylski, M
    Pompe, W
    Rödel, G
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (09) : 1236 - 1243
  • [10] Detection and characterization of zinc- and cadmium-binding proteins in Escherichia coli by gel electrophoresis and laser ablation-inductively coupled plasma-mass spectrometry
    Binet, MRB
    Ma, RL
    McLeod, CW
    Poole, RK
    [J]. ANALYTICAL BIOCHEMISTRY, 2003, 318 (01) : 30 - 38