Test-retest reliability of dynamic plantar loading and foot geometry measures in diabetics with peripheral neuropathy

被引:17
作者
Gurney, J. K. [1 ,2 ]
Marshall, P. W. M. [3 ]
Rosenbaum, D. [4 ]
Kersting, U. G. [5 ]
机构
[1] Univ Auckland, Dept Sport & Exercise Sci, Auckland 1, New Zealand
[2] Univ Otago, Dept Publ Hlth, Wellington Sch Med, Wellington, New Zealand
[3] Univ Western Sydney, Sch Biomed & Hlth Sci, Penrith, NSW 1797, Australia
[4] Univ Hosp Munster, Dept Orthopaed, Munster, Germany
[5] Aalborg Univ, Ctr Sensory Motor Interact, Aalborg, Denmark
关键词
Foot; Pressure; Geometry; Diabetes; Neuropathy; NORMAL-PRESSURE VALUES; REPEATABILITY; POPULATION; SYSTEM;
D O I
10.1016/j.gaitpost.2012.06.007
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Pedobarography is commonly employed in patients with diabetic peripheral neuropathy (DPN). However there is no evidence regarding test-retest reliability of this technique in this population, and therefore it was the purpose of the current study to address this clear gap. Dynamic plantar loading and foot geometry data were collected during barefoot gait with the EMED platform (Novel GmbH, Germany) from 10 patients with DPN over two sessions, separated by 28 days. Intra-class Correlation Coefficients (ICCs) and Coefficients of Variation (CoVs) were calculated to determine test-retest reliability. For dynamic plantar loading, reliability differed by outcome measure and foot region, with ICCs of >0.8 and CoVs of <15% observed in most cases. For dynamic foot geometry, ICCs of >0.88 and CoVs of <3% were observed for hallux angle, arch index and coefficient of spreading, while sub-arch angle was less reliable (ICC 0.76, Coy 23%). Overall, the current study observed high levels of test-retest reliability which were generally commensurate with that previously reported in healthy populations. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:135 / 137
页数:3
相关论文
共 9 条
[1]   Test-retest reliability and descriptive statistics of geometric measurements based on plantar pressure measurements in a healthy population during gait [J].
Akins, Jonathan S. ;
Keenan, Karen A. ;
Sell, Timothy C. ;
Abt, John P. ;
Lephart, Scott M. .
GAIT & POSTURE, 2012, 35 (01) :167-169
[2]   The 10-g monofilament - The diagnostic divining rod for the diabetic foot? [J].
Armstrong, DG .
DIABETES CARE, 2000, 23 (07) :887-887
[3]  
Cavanagh P.R., 1994, FOOT, V4, P123, DOI DOI 10.1016/0958-2592(94)90017-5
[4]   Increased variability of continuous overground walking in neuropathic patients is only indirectly related to sensory loss [J].
Dingwell, JB ;
Cavanagh, PR .
GAIT & POSTURE, 2001, 14 (01) :1-10
[5]   Reliability of instrumented movement analysis as outcome measure in Charcot-Marie-Tooth disease: Results from a multitask locomotor protocol [J].
Ferrarin, M. ;
Bovi, G. ;
Rabuffetti, M. ;
Mazzoleni, P. ;
Montesano, A. ;
Moroni, I. ;
Pagliano, E. ;
Marchi, A. ;
Marchesi, C. ;
Beghi, E. ;
Pareyson, D. .
GAIT & POSTURE, 2011, 34 (01) :36-43
[6]   Between-day reliability of repeated plantar pressure distribution measurements in a normal population [J].
Gurney, Jason K. ;
Kersting, Uwe G. ;
Rosenbaum, Dieter .
GAIT & POSTURE, 2008, 27 (04) :706-709
[7]   Dynamic foot function and morphology in elite rugby league athletes of different ethnicity [J].
Gurney, Jason K. ;
Kersting, Uwe G. ;
Rosenbaum, Dieter .
APPLIED ERGONOMICS, 2009, 40 (03) :554-559
[8]   Normal pressure values and repeatability of the Emed® ST2 system [J].
Maetzler, M. ;
Bochdansky, T. ;
Abboud, R. J. .
GAIT & POSTURE, 2010, 32 (03) :391-394
[9]   Normal pressure values and repeatability of the Emed® ST4 system [J].
Putti, A. B. ;
Arnold, G. P. ;
Cochrane, L. A. ;
Abboud, R. J. .
GAIT & POSTURE, 2008, 27 (03) :501-505