Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms

被引:271
作者
Nuyts, J [1 ]
Dupont, P
Stroobants, S
Benninck, R
Mortelmans, L
Suetens, P
机构
[1] Katholieke Univ Leuven, Dept Nucl Med, Louvain, Belgium
[2] Katholieke Univ Leuven, ESAT Machine Intelligence & Imaging, Louvain, Belgium
关键词
attenuation correction; maximum-likelihood reconstruction; PET; SPECT;
D O I
10.1109/42.774167
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In order to perform attenuation correction in emission tomography an attenuation map is required. We propose a new method to compute this map directly from the emission sinogram, eliminating the transmission scan from the acquisition protocol. The problem is formulated as an optimization task where the objective function is a combination of the likelihood and an a priori probability. The latter uses a Gibbs prior distribution to encourage local smoothness and a multimodal distribution for the attenuation coefficients. Since the attenuation process is different in positron emission tomography (PET) and single photon emission tomography (SPECT), a separate algorithm for each case is derived, The method has been tested on mathematical phantoms and on a few clinical studies. For PET, good agreement was found between the images obtained with transmission measurements and those produced by the new algorithm in an abdominal study. For SPECT, promising simulation results have been obtained for nonhomogeneous attenuation due to the presence of the lungs.
引用
收藏
页码:393 / 403
页数:11
相关论文
共 30 条
[1]   APPROXIMATE RECONSTRUCTION OF ATTENUATION MAP IN SPECT IMAGING [J].
BRONNIKOV, AV .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (05) :1483-1488
[2]   NEW APPROACH TO THE EMISSION COMPUTERIZED TOMOGRAPHY PROBLEM - SIMULTANEOUS CALCULATION OF ATTENUATION AND ACTIVITY-COEFFICIENTS [J].
CENSOR, Y ;
GUSTAFSON, DE ;
LENT, A ;
TUY, H .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) :2775-2779
[3]   Detailed investigation of transmission and emission data smoothing protocols and their effects on emission images [J].
Chatziioannou, A ;
Dahlbom, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (01) :290-294
[4]  
Clinthome NH, 1991, IEEE NUCLEAR SCI S M, V3, P1927
[5]  
ERDOGAN H, 1996, IEEE NUCL SCI S MED, V3, P1579
[6]   Grouped-coordinate ascent algorithms for penalized-likelihood transmission image reconstruction [J].
Fessler, JA ;
Ficaro, EP ;
Clinthorne, NH ;
Lange, K .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :166-175
[7]   STOCHASTIC RELAXATION, GIBBS DISTRIBUTIONS, AND THE BAYESIAN RESTORATION OF IMAGES [J].
GEMAN, S ;
GEMAN, D .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1984, 6 (06) :721-741
[8]  
Geman S, 1987, Bull Int Stat Inst, V4, P5
[9]   ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA [J].
HUDSON, HM ;
LARKIN, RS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) :601-609
[10]   MAXIMUM-LIKELIHOOD, LEAST-SQUARES, AND PENALIZED LEAST-SQUARES FOR PET [J].
KAUFMAN, L .