Development of MEPS-UHPLC/PDA methodology for the quantification of clozapine, risperidone and their major active metabolites in human urine

被引:20
作者
Goncalves, Joao L. [1 ,2 ]
Alves, Vera L. [1 ,2 ]
Conceicao, Carlota J. F. [1 ]
Teixeira, Helena M. [2 ,3 ]
Camara, Jose S. [1 ]
机构
[1] Univ Madeira, CQM UMa, Ctr Quim Madeira, Ctr Ciencias Exactas & Engn, P-9000390 Funchal, Portugal
[2] Univ Coimbra, Fac Med, P-3000548 Coimbra, Portugal
[3] Inst Nacl Med Legal & Ciencias Forenses IP, Delegacao Ctr, P-3000213 Coimbra, Portugal
关键词
Antipsychotics; Clozapine; Risperidone; Microextraction by packed sorbent; Ultra high pressure liquid chromatography; PACKED SORBENT MEPS; PRESSURE LIQUID-CHROMATOGRAPHY; HUMAN PLASMA; ANTIPSYCHOTIC-DRUGS; MASS-SPECTROMETRY; UTILIZING MICROEXTRACTION; ATYPICAL ANTIPSYCHOTICS; POWERFUL TECHNIQUE; PERFORMANCE; MS/MS;
D O I
10.1016/j.microc.2015.05.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, fast and reliable methodology using a digitally controlled microextraction by packed sorbent (MEPS), followed by ultrahigh pressure liquid chromatography (UHPLC) separation combined with a photodiode array (PDA) detection, has been developed and validated for the simultaneous determination of clozapine and risperidone, and their active metabolites, in urine samples. Important parameters affecting MEPS performance, including type of sorbent material (C-2, C-8, C-18, SIL, M1, R-AX, R-CX, PGC, PEP, HLB-DVB and H-DVB), elution solvent system, number of extraction cycles, sample volume, elution volume, and sample pH, were evaluated. The optimal experimental conditions involved the loading of 500 mu l of sample through a C-18 sorbent in a five extraction cycles and in a short time period (5 min for the entire sample preparation step). The obtained extract was analyzed by UHPLC, using a binary mobile phase, composed of aqueous 0.1% formic acid and methanol in the gradient elution mode (10 min total analysis). Good results were obtained under the optimized conditions, in terms of linearity with correlation coefficients (r(2)) values higher than 0.9986. Low detection limits, ranging between 0.052 and 0.055 mu g ml(-1) were achieved, whereas the lowest quantification limit was 0.1 mu g ml(-1) corresponding to the lowest concentration of the standard curve. Satisfactory results were found with accuracy values ranging from 83% to 116%, and with precision results from 2.65% to 18%. Recoveries ranged between 76% and 96%, which was in agreement with results reported by other studies. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 98
页数:9
相关论文
共 45 条
[1]   Recent advances in microextraction by packed sorbent for bioanalysis [J].
Abdel-Rehim, Mohamed .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (16) :2569-2580
[2]  
Alamo C., 2013, Clinical and Experimental Pharmacology, V3, P117, DOI DOI 10.4172/2161-1459.1000117
[3]   Study of the factors affecting the performance of microextraction by packed sorbent (MEPS) using liquid scintillation counter and liquid chromatography-tandem mass spectrometry [J].
Altun, Zeki ;
Abdel-Rehim, Mohamed .
ANALYTICA CHIMICA ACTA, 2008, 630 (02) :116-123
[4]   Microextraction in packed sorbent for analysis of antidepressants in human plasma by liquid chromatography and spectrophotometric detection [J].
Chaves, Andrea R. ;
Leandro, Fernanda Z. ;
Carris, Juciene A. ;
Queiroz, Maria Eugenia C. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (23) :2123-2129
[5]   Determination of seven selected antipsychotic drugs in human plasma using microextraction in packed sorbent and gas chromatography-tandem mass spectrometry [J].
da Fonseca, B. M. ;
Moreno, I. E. D. ;
Barroso, M. ;
Costa, S. ;
Queiroz, J. A. ;
Gallardo, E. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (12) :3953-3963
[6]   A method based on microextraction by packed sorbent-programmed temperature vaporizer-fast gas chromatography-mass spectrometry for the determination of aromatic amines in environmental water samples [J].
del Nogal Sanchez, Miguel ;
Perez Sappo, Cristina ;
Perez Pavon, Jose Luis ;
Moreno Cordero, Bernardo .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (6-7) :2007-2015
[7]   Determination of dopamine and serotonin in human urine samples utilizing microextraction online with liquid chromatography/electrospray tandem mass spectrometry [J].
El-Beqqali, Aziza ;
Kussak, Anders ;
Abdel-Rehim, Mohamed .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (03) :421-424
[8]  
Galbraith A., 2007, ANTIPSYCHOTIC DRUGS, P295
[9]  
Ginovart N, 2012, HANDB EXP PHARMACOL, V212, P27, DOI 10.1007/978-3-642-25761-2_2
[10]   An attractive, sensitive and high-throughput strategy based on microextraction by packed sorbent followed by UHPLC-PDA analysis for quantification of hydroxybenzoic and hydroxycinnamic acids in wines [J].
Goncalves, Joao ;
Silva, Catarina L. ;
Castilho, Paula C. ;
Camara, Jose S. .
MICROCHEMICAL JOURNAL, 2013, 106 :129-138