Validity and Comparability of a Wrist-Worn Accelerometer in Children

被引:76
|
作者
Ekblom, Orjan [1 ]
Nyberg, Gisela [2 ]
Bak, Elin Ekblom [1 ]
Ekelund, Ulf [3 ]
Marcus, Claude [2 ]
机构
[1] Swedish Sch Sport & Hlth Sci, Astrand Lab Work Physiol, Stockholm, Sweden
[2] Dept Clin Sci Intervent & Technol, Stockholm, Sweden
[3] Inst Metab Sci, MRC Epidemiol Unit, Cambridge, England
来源
JOURNAL OF PHYSICAL ACTIVITY & HEALTH | 2012年 / 9卷 / 03期
基金
英国医学研究理事会;
关键词
Actigraph; Actiwatch; cut-off values; energy expenditure; indirect calorimetry; PHYSICAL-ACTIVITY; ENERGY-EXPENDITURE; ACTIVITY MONITOR; FAT;
D O I
10.1123/jpah.9.3.389
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Wrist-worn accelerometers may provide an alternative to hip-worn monitors for assessing physical activity as they are easier to wear and may thus facilitate long-term recordings. The current study aimed at a) assessing the validity of the Actiwatch (wrist-worn) for estimating energy expenditure, b) determining cut-off values for light, moderate, and vigorous activities, c) studying the comparability between the Actiwatch and the Actigraph (hip-worn), and d) assessing reliability. Methods: For validity, indirect calorimetry was used as criterion measure. ROC-analyses were applied to identify cut-off values. Comparability was tested by simultaneously wearing of the 2 accelerometers during free-living condition. Reliability was tested in a mechanical shaker. Results: All-over correlation between accelerometer output and energy expenditure were found to be 0.80 (P < .001). Based on ROC-analysis, cut-off values for 1.5, 3, and 6 METs were found to be 80, 262, and 406 counts per 15 s, respectively. Energy expenditure estimates differed between the Actiwatch and the Actigraph (P < .05). The intra- and interinstrument coefficient of variation of the Actiwatch ranged between 0.72% and 8.4%. Conclusion: The wrist-worn Actiwatch appears to be valid and reliable for estimating energy expenditure and physical activity intensity in children aged 8 to 10 years.
引用
收藏
页码:389 / 393
页数:5
相关论文
共 50 条
  • [1] Technical variability of the Vivago® wrist-worn accelerometer
    Vanhelst, Jeremy
    Fardy, Paul S.
    Beghin, Laurent
    JOURNAL OF SPORTS SCIENCES, 2014, 32 (19) : 1768 - 1774
  • [2] Validity Of Wrist-worn Activity Trackers
    De Lucia, Bianca J.
    Lynch, Victoria E.
    Kowalczyk, Kayla M.
    Wade, Jessica M.
    Hudak, Jonathan R.
    Stannard, Alicja B.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 517 - 517
  • [3] The validity of the GENEActiv wrist-worn accelerometer for measuring adult sedentary time in free living
    Pavey, Toby G.
    Gomersall, Sjaan R.
    Clark, Bronwyn K.
    Brown, Wendy J.
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2016, 19 (05) : 395 - 399
  • [4] Personalized gait detection using a wrist-worn accelerometer
    Cola, Guglielmo
    Avvenuti, Marco
    Musso, Fabio
    Vecchio, Alessio
    2017 IEEE 14TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2017, : 173 - 177
  • [5] Comparison Of Wrist-worn Accelerometer Output Based On Handedness
    Welch, Whitney A.
    Strath, Scott J.
    Swartz, Ann M.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 789 - 789
  • [6] The backwards comparability of wrist worn GENEActiv and waist worn ActiGraph accelerometer estimates of sedentary time in children
    Boddy, Lynne M.
    Noonan, Robert J.
    Rowlands, Alex V.
    Hurter, Liezel
    Knowles, Zoe R.
    Fairclough, Stuart J.
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2019, 22 (07) : 814 - 820
  • [7] Validation of the Vivago Wrist-Worn accelerometer in the assessment of physical activity
    Jérémy Vanhelst
    Rémy Hurdiel
    Jacques Mikulovic
    Gilles Bui-Xuân
    Paul Fardy
    Denis Theunynck
    Laurent Béghin
    BMC Public Health, 12
  • [8] Subject Recognition Using Wrist-Worn Triaxial Accelerometer Data
    Mauceri, Stefano
    Smith, Louis
    Sweeney, James
    McDermott, James
    MACHINE LEARNING, OPTIMIZATION, AND BIG DATA, MOD 2017, 2018, 10710 : 574 - 585
  • [9] Physical Activity Classification Using the GENEA Wrist-Worn Accelerometer
    Zhang, Shaoyan
    Rowlands, Alex V.
    Murray, Peter
    Hurst, Tina L.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 (04): : 742 - 748
  • [10] Reference values for wrist-worn accelerometer physical activity metrics in England children and adolescents
    Stuart J. Fairclough
    Alex V. Rowlands
    Borja del Pozo Cruz
    Matteo Crotti
    Lawrence Foweather
    Lee E. F. Graves
    Liezel Hurter
    Owen Jones
    Mhairi MacDonald
    Deborah A. McCann
    Caitlin Miller
    Robert J. Noonan
    Michael B. Owen
    James R. Rudd
    Sarah L. Taylor
    Richard Tyler
    Lynne M. Boddy
    International Journal of Behavioral Nutrition and Physical Activity, 20