Evaluation of GI bleeding after implantation of left ventricular assist device

被引:74
作者
Kushnir, Vladimir M. [1 ]
Sharma, Shivak [2 ]
Ewald, Gregory A. [2 ]
Seccombe, Jonathan [3 ]
Novak, Eric [2 ]
Wang, I-Wen [4 ]
Joseph, Susan M. [2 ]
Gyawali, C. Prakash [1 ]
机构
[1] Washington Univ, Sch Med, Div Gastroenterol, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Div Cardiol, St Louis, MO USA
[3] Washington Univ, Sch Med, Dept Internal Med, St Louis, MO 63110 USA
[4] Washington Univ, Sch Med, Div Cardiothorac Surg, St Louis, MO 63110 USA
关键词
END-ORGAN FUNCTION; VON-WILLEBRAND-SYNDROME; CONTINUOUS-FLOW; PULSATILE; SUPPORT; NONPULSATILE; COMPLICATIONS; ENDOSCOPY;
D O I
10.1016/j.gie.2011.12.014
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Left ventricular assist devices (LVADs) have revolutionized the management of end-stage heart failure (ESHF). However, unexpectedly high rates of GI bleeding (GIB) have been described, and etiology and outcome remain unclear. Objective: To determine the prevalence, etiology, and outcome of GIB in LVAD recipients. Design: Retrospective case series. Setting: Tertiary care academic university hospital. Patients: 154 ESHF patients (55.4 years, 122 men/32 women) with LVADs implanted over a 10-year period. Main outcome measurements: Overt or occult GIB prompting endoscopic evaluation >= 7 days after LVAD implantation. Results: Over a mean of 0.9 +/- 0.1 years of follow-up, 29 patients (19%) experienced 44 GIB episodes. Patients with GIB were older and received anticoagulation therapy before devices were implanted (P <= .02 for each). GIB was overt (n = 31) rather than occult (n = 13), and most patients presented with melena (n = 22, 50%); hemodynamic instability was observed in 13.6%. Each bleeding episode required 2.1 +/- 0.1 diagnostic or therapeutic procedures, and a source was localized in 71%. Upper endoscopy provided the highest diagnostic yield; peptic bleeding (n = 14) and vascular malformations (n = 8) dominated the findings. Endoscopy was safe and well tolerated. Overall mortality was 35%, none directly from GIB. Limitation: Retrospective design. Conclusions: Rates of GIB with LVADs are higher than that seen in other patient populations, including those receiving anticoagulation and antiplatelet therapy. GIB episodes are mostly overt and predominantly from the upper GI tract. Endoscopy is safe in the LVAD population. (Gastrointest Endosc 2012;75:973-9.)
引用
收藏
页码:973 / 979
页数:7
相关论文
共 29 条
[11]   Characterization of Gastrointestinal Bleeding in HeartMate II Left Ventricular Assist Device Patients [J].
Mason, N. O. ;
Reid, B. B. ;
Harmstan, G. ;
Jones, J. ;
Stoker, S. ;
Budge, D. ;
Alharethi, R. ;
Thomsen, G. ;
Clayson, S. E. ;
Caine, W. ;
Kfoury, A. G. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (02) :S175-S175
[12]   Systolic Heart Failure [J].
McMurray, John J. V. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (03) :228-238
[13]   Use of a continuous-flow device in patients awaiting heart transplantation [J].
Miller, Leslie W. ;
Pagani, Francis D. ;
Russell, Stuart D. ;
John, Ranjit ;
Boyle, Andrew J. ;
Aaronson, Keith D. ;
Conte, John V. ;
Naka, Yoshifumi ;
Mancini, Donna ;
Delgado, Reynolds M. ;
MacGillivray, Thomas E. ;
Farrar, David J. ;
Frazier, O. H. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (09) :885-896
[14]  
Muthiah K, 2010, HEART LUNG CIRC, V19, pS70
[15]   End-organ function in patients on long-term circulatory support with continuous- or Pulsatile-flow assist devices [J].
Radovancevic, Branislav ;
Vrtovec, Bojan ;
de Kort, Elizabeth ;
Radovancevic, Rajko ;
Gregoric, Igor D. ;
Frazier, O. H. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2007, 26 (08) :815-818
[16]   Long-term use of a left ventricular assist device for end-stage heart failure [J].
Rose, EA ;
Gelijns, AC ;
Moskowitz, AJ ;
Heitjan, DF ;
Stevenson, LW ;
Dembitsky, W ;
Long, JW ;
Ascheim, DD ;
Tierney, AR ;
Levitan, RG ;
Watson, JT ;
Meier, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (20) :1435-1443
[17]   End-organ function during chronic nonpulsatile circulation [J].
Saito, S ;
Westaby, S ;
Piggot, D ;
Dudnikov, S ;
Robson, D ;
Catarino, PA ;
Clelland, C ;
Nojiri, C .
ANNALS OF THORACIC SURGERY, 2002, 74 (04) :1080-1085
[18]   Bleeding Complications and Blood Product Utilization With Left Ventricular Assist Device Implantation [J].
Schaffer, Justin M. ;
Arnaoutakis, George J. ;
Allen, Jeremiah G. ;
Weiss, Eric S. ;
Patel, Nishant D. ;
Russell, Stuart D. ;
Shah, Ashish S. ;
Conte, John V. .
ANNALS OF THORACIC SURGERY, 2011, 91 (03) :740-749
[19]   Renal circulation and cellular metabolism during left ventricular assisted circulation: Comparison study of pulsatile and nonpulsatile assists [J].
Sezai, A ;
Shiono, M ;
Orime, Y ;
Nakata, K ;
Hata, M ;
Yamada, H ;
Iida, M ;
Kashiwazaki, S ;
Kinishita, J ;
Nemoto, M ;
Koujima, T ;
Sezai, Y ;
Saitoh, T .
ARTIFICIAL ORGANS, 1997, 21 (07) :830-835
[20]  
Siddiqui MA, 2009, GASTROENTEROLOGY, V136, pA213